DOE OSTI · 1971588
Verification Problems for Smooth Step Amplitude Load Curves in DYNA3D/Paradyn
Abstract
This report documents the addition of three new verification tests in the LOADCURVE directory of the DYNA3D/Paradyn Software Quality Assurance test suite. Each test consists of a single element, where the velocities of each node are specified by either the newly added smooth step tabular load curve or another load curve option. The first test assesses the initialization and interpolation of the newly inputted load curve option through tabulated abscissa-ordinate pairs of data. The second test uses the same set of abscissa-ordinate data points and applies offset and scaling parameters available within the load curve definition. The third test defines the smooth step load curve in an original input deck, and assesses its correct redefinition using a restart file. The simulation velocities are compared to their true values at discrete points in time, and each test is verified up to numerical precision. These results confirm that the smooth step load curve option is functioning correctly and as intended.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Zoller, Miklos Johann. 2023-04-05. Verification Problems for Smooth Step Amplitude Load Curves in DYNA3D/Paradyn. https://doi.org/10.2172/1971588
Cite the original work for its findings. Save a collection to share your selection of sources.