DOE OSTI · 1981721
Improvements of pre-emptive identification of particle accelerator failures using binary classifiers and dimensionality reduction
Abstract
In this paper we look at the properties of the Spallation Neutron Source (SNS) Differential Beam Current Monitor (DCM) data and various methods of data transformation to improve pre-emptive detection of machine trips. In this study, the foundation of the approach is the analysis of new underlying data and understanding various properties with the goal of faster classification, higher precision and higher recall with the aim to reduce false positives as low as required. The result of the research presented in this paper are a binary classifier capable of predicting accelerator failures with millisecond classification time, 96% precision, 58% true positive and 0% false positive rate and optimization techniques enabling real-time implementations.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Reščič, Miha, Seviour, Rebecca, Blokland, Willem. 2021-12-11. Improvements of pre-emptive identification of particle accelerator failures using binary classifiers and dimensionality reduction. https://doi.org/10.1016/j.nima.2021.166064
Cite the original work for its findings. Save a collection to share your selection of sources.