DOE OSTI · 1989892
Flow rate optimization for a small liquid argon system at Fermilab.
Abstract
This analysis highlights the dominant role of pressure loss in filter disks, emphasizing its crucial consideration during the design phase to ensure optimal fluid flow. Additionally, the significance of vapor quality at the transfer line inlet is identified as a key factor impacting the fill rate. Reducing inlet vapor quality and exploring the use of subcooled liquid are recommended approaches to enhance system performance.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Koshelev, Sergey. 2023-07-13. Flow rate optimization for a small liquid argon system at Fermilab.. https://doi.org/10.2172/1989892
Cite the original work for its findings. Save a collection to share your selection of sources.