Search NASA⌕ Search

DOE OSTI · 2006987

PW2 Pumping: March 18 thru March 22, 2020

Abstract

Processed Coherence-length-gated Microwave Photonics Interferometry (CMPI) distributed vertical strain on March 18 through March 22, 2020 at the hydromechanical test facility located at the Clemson University Simpson Station research facility in Central, South Carolina, USA. This includes ambient data in addition to a pumping test performed between 14:31-20:31 EST on 3/22/2020 from Pumping Well 2 (PW2). These data are from a strain ribbon that was deployed in the vadose zone at approximately 34.670130°N, -82.729524°E from the ground surface to a depth of 8m in saprolite containing weak reflectors pairs were placed every 0.85 m along the fiber. Each weak reflector pair forms a 15 cm cavity strain meter. Strain unit: meters/meter (strain). Sampling rate 0.1 Hz. Each column corresponds to the strain data taken at a depth d from the ground surface. c1: d = 1.00m c2: d = 1.85m c3: d = 2.70m c4: d = 3.55m (large demodulation error) c5: d = 4.40m c6: d = 5.25m c7: d = 6.10m (large demodulation error) c8: d = 6.95m

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

DeWolf, Scott, Hua, Liwei, Murdoch, Lawrence C, Blais, Riley. 2023-10-02. PW2 Pumping: March 18 thru March 22, 2020. https://doi.org/10.18141/2006987

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Real-time well integrity monitoring in underground gas storage wells using distributed temperature and strain sensing: a field demonstration

Here, this article presents the first successful field demonstration of a combined distributed temperature and strain sensing (DTSS) system installed directly on newly replaced tubing in a 5400-ft-deep operational underground gas storage well. The DTSS system uses a single optical fiber to monitor temperature and strain in real-time, providing a cost-effective solution for long-term well integrity assessment. In this study, the strain–stress correlation of the tubing—representative of material behavior analysis—is investigated as a potential method for monitoring tubing integrity throughout its lifetime. Moreover, the DTSS system’s capability to support both continuous and discrete monitoring is evaluated by comparing future data with historical records, enabling the early detection of issues such as material fatigue, corrosion, or deformation. Overall, the work examines the effectiveness and scalability of the DTSS system for real-time monitoring of well operations and integrity in a newly replaced well.

Distributed Strain Sensing↗