Search NASA⌕ Search

DOE OSTI · 21036191

A practical global distortion correction method for an image intensifier based x-ray fluoroscopy system

Abstract

X-ray images acquired on systems with image intensifiers (II) exhibit characteristic distortion which is due to both external and internal factors. The distortion is dependent on the orientation of the II, a fact particularly relevant to II's mounted on C arms which have several degrees of freedom of motion. Previous descriptions of distortion correction strategies have relied on a dense sampling of the C-arm orientation space, and as such have been limited mostly to a single arc of the primary angle, {alpha}. We present a new method which smooths the trajectories of the segmented vertices of the grid phantom as a function of {alpha} prior to solving the two-dimensional warping problem. It also shows that the same residual errors of distortion correction could be achieved without fitting the trajectories of the grid vertices, but instead applying the previously described global method of distortion correction, followed by directly smoothing the values of the polynomial coefficients as functions of the C-arm orientation parameters. When this technique was applied to a series of test images at arbitrary {alpha}, the root-mean-square (RMS) residual error was 0.22 pixels. The new method was extended to three degrees of freedom of the C-arm motion: the primary angle, {alpha}; the secondary angle, {beta}; and the source-to-intensifier distance, {lambda}. Only 75 images were used to characterize the distortion for the following ranges: {alpha}, {+-}45 deg. ({delta}{alpha}=22.5 deg.); {beta}, {+-}36 deg. ({delta}{beta}=18 deg.); {lambda}, 98-118 cm ({delta}{lambda}=10 cm). When evaluated on a series of test images acquired at arbitrary ({alpha},{beta},{lambda}), the RMS residual error was 0.33 pixels. This method is targeted at applications such as guidance of catheter-based interventions and treatment planning for brachytherapy, which require distortion-corrected images over a large range of C-arm orientations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gutierrez, Luis F, Ozturk, Cengizhan, McVeigh, Elliot R, Lederman, Robert J. 2008-03-15. A practical global distortion correction method for an image intensifier based x-ray fluoroscopy system. https://doi.org/10.1118/1.2839099. https://searchnasa.com/record/osti%3A21036191/a-practical-global-distortion-correction-method-for-an-image-intensifier-based-x-ray-fluoroscopy-sys

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search NASA by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related reports

Cross sections of 147–149 Sm( 6 Li,x) reactions for the production of 149 Tb for targeted alpha therapy

Terbium-149g (t 1/2 = 4.12 h) is of particular interest for targeted alpha therapy cancer treatment due to its ability to decay via both alpha and positron emission, making it a potential theranostic nuclide. Due to many challenges facing its production, there are limited facilities worldwide that have demonstrated the ability to produce this nuclide in quantities sufficient for medical research. Since the Cyclotron Institute at Texas A&M University is a specialized accelerator facility capable of accelerating a wide variety of ions, we are investigating production pathway options. One of the major challenges facing its production is the known co-production of the excited isomeric state, 149m Tb (t 1/2 = 4.1 min). However, this state does not decay to the ground state of 149g Tb, negating any potential contribution to its yield. Due to its short-half life, the cross section for the population of this state has never been measured. After calculating several potential reaction yields using predictive models, the reactions of 147–149 Sm( 6 Li,xn) 149 Tb were identified as candidates. Lithium-6 beams of varied energies between 45-65 MeV were impinged on enriched 147 Sm, 148 Sm, and 149 Sm targets at the Cyclotron Institute at Texas A&M University, and the reaction products were measured immediately following irradiation using high-purity germanium detectors, enabling detection of both 149m Tb and 149g Tb. Cross sections for all nuclides produced in sufficient activity in these reactions were also measured and reported here. We conclude that the population of 149m Tb is much preferred over population of the ground state for these 6 Li-induced reactions, and it is necessary to explore other options for 149g Tb production.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Source function from two-particle correlation function through entropy-regularized Richardson-Lucy deblurring

Source functions are obtained from p – p and d – α correlation functions by applying the Richardson-Lucy (RL) deblurring to the Koonin-Pratt (KP) equation. To prevent fitting of noise in the correlation function, total-variation (TV) regularization is employed that has been effective in ordinary image restoration. TV alone cannot ensure normalization of the source functions. To ensure the latter, we propose a maximum-entropy regularized RL algorithm (MEM-RL). We outline the MEM-RL formalism and optimization strategy for the KP equation, demonstrating its effectiveness on both simulated and experimental data, including the p – p and d – α correlation functions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗