Abstract
After operating for more than 25 years, some of the Reaktor TRIGA Puspati (RTP) fuel elements would have been depleted. A few addition and fuel reconfiguration exercises have to be conducted in order to maintain RTP capacity. Presently, RTP spent fuels are stored at the storage area inside RTP tank. The need to transfer the fuel element outside of RTP tank may be prevalence in the near future. The preparation shall be started from now. A fuel element transfer cask has been designed according to the recommendation by the fuel manufacturer and experience of other countries. A modelling using MCNP code has been conducted to analyse the design. The result shows that the design of transfer cask fuel element is safe for handling outside the RTP tank according to recent regulatory requirement.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Darmawan, Rosli, Topah, Budiman Naim. 2010-01-05. Fuel Element Transfer Cask Modelling Using MCNP Technique. https://doi.org/10.1063/1.3295593