DOE OSTI · 21611686
Surface Plasma Source Electrode Activation by Surface Impurities
Abstract
In experiments with RF saddle antenna surface plasma sources (SPS), the efficiency of H{sup -} ion generation was increased by up to a factor of 5 by plasma electrode 'activation', without supplying additional Cs, by heating the collar to high temperature for several hours using hot air flow and plasma discharge. Without cracking or heating the cesium ampoule, but likely with Cs recovery from impurities, the achieved energy efficiency was comparable to that of conventionally cesiated SNS RF sources with an external or internal Cs supply. In the experiments, optimum cesiation was produced (without additional Cs) by the collection and trapping of traces of remnant cesium compounds from SPS surfaces. Such activation by accumulation of impurities on electrode surfaces can be a reason for H{sup -} emission enhancement in other so-called 'volume' negative ion sources.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Dudnikov, Vadim, Johnson, Rolland P, Han, B, Murray, S N, Pennisi, T R, Santana, M, Stockli, Martin P, Welton, R F. 2011-09-26. Surface Plasma Source Electrode Activation by Surface Impurities. https://doi.org/10.1063/1.3637412
Cite the original work for its findings. Save a collection to share your selection of sources.