Search NASA⌕ Search

DOE OSTI · 22494541

Concrete density estimation by rebound hammer method

Abstract

Concrete is the most common and cheap material for radiation shielding. Compressive strength is the main parameter checked for determining concrete quality. However, for shielding purposes density is the parameter that needs to be considered. X- and -gamma radiations are effectively absorbed by a material with high atomic number and high density such as concrete. The high strength normally implies to higher density in concrete but this is not always true. This paper explains and discusses the correlation between rebound hammer testing and density for concrete containing hematite aggregates. A comparison is also made with normal concrete i.e. concrete containing crushed granite.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Masenwat, Noor Azreen bin, Sani, Suhairy bin, Mohd, Shukri, Jefri, Muhamad Hafizie Bin, Abdullah, Mahadzir Bin, Isa, Nasharuddin bin, Mahmud, Mohamad Haniza bin. 2016-01-22. Concrete density estimation by rebound hammer method. https://doi.org/10.1063/1.4940087

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Novel Method for Domestic Stable Isotope Production (CRADA #667) Final Report

This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species (35Cl- and 37Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.

07 ISOTOPE AND RADIATION SOURCES↗