DOE OSTI · 22494541
Concrete density estimation by rebound hammer method
Abstract
Concrete is the most common and cheap material for radiation shielding. Compressive strength is the main parameter checked for determining concrete quality. However, for shielding purposes density is the parameter that needs to be considered. X- and -gamma radiations are effectively absorbed by a material with high atomic number and high density such as concrete. The high strength normally implies to higher density in concrete but this is not always true. This paper explains and discusses the correlation between rebound hammer testing and density for concrete containing hematite aggregates. A comparison is also made with normal concrete i.e. concrete containing crushed granite.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Masenwat, Noor Azreen bin, Sani, Suhairy bin, Mohd, Shukri, Jefri, Muhamad Hafizie Bin, Abdullah, Mahadzir Bin, Isa, Nasharuddin bin, Mahmud, Mohamad Haniza bin. 2016-01-22. Concrete density estimation by rebound hammer method. https://doi.org/10.1063/1.4940087
Cite the original work for its findings. Save a collection to share your selection of sources.