Search NASA⌕ Search

DOE OSTI · 22723019

Evaluating the Toxicity Reduction With Computed Tomographic Ventilation Functional Avoidance Radiation Therapy

Abstract

Purpose: Computed tomographic (CT) ventilation imaging is a new modality that uses 4-dimensional (4D) CT information to calculate lung ventilation. Although retrospective studies have reported on the reduction in dose to functional lung, no work to our knowledge has been published in which the dosimetric improvements have been translated to a reduction in the probability of pulmonary toxicity. Our work estimates the reduction in toxicity for CT ventilation–based functional avoidance planning. Methods and Materials: Seventy previously treated lung cancer patients who underwent 4DCT imaging were used for the study. CT ventilation maps were calculated with 4DCT deformable image registration and a density change–based algorithm. Pneumonitis was graded on the basis of imaging and clinical presentation. Maximum likelihood methods were used to generate normal tissue complication probability (NTCP) models predicting grade 2 or higher (2+) and grade 3+ pneumonitis as a function of dose (V5 Gy, V10 Gy, V20 Gy, V30 Gy, and mean dose) to functional lung. For 30 patients a functional plan was generated with the goal of reducing dose to the functional lung while meeting Radiation Therapy Oncology Group 0617 constraints. The NTCP models were applied to the functional plans and the clinically used plans to calculate toxicity reduction. Results: By the use of functional avoidance planning, absolute reductions in grade 2+ NTCP of 6.3%, 7.8%, and 4.8% were achieved based on the mean fV20 Gy, fV30 Gy, and mean dose to functional lung metrics, respectively. Absolute grade 3+ NTCP reductions of 3.6%, 4.8%, and 2.4% were achieved with fV20 Gy, fV30 Gy, and mean dose to functional lung. Maximum absolute reductions of 52.3% and 16.4% were seen for grade 2+ and grade 3+ pneumonitis for individual patients. Conclusion: Our study quantifies the possible toxicity reduction from CT ventilation–based functional avoidance planning. Reductions in grades 2+ and 3+ pneumonitis were 7.1% and 4.7% based on mean dose-function metrics, with reductions as high as 52.3% for individual patients. Our work provides seminal data for determining the potential toxicity benefit from incorporating CT ventilation into thoracic treatment planning.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Miyasaka, Yuya, Kadoya, Noriyuki, Castillo, Richard, Castillo, Edward, Vinogradskiy, Yevgeniy, Yamamoto, Tokihiro. 2017-10-01. Evaluating the Toxicity Reduction With Computed Tomographic Ventilation Functional Avoidance Radiation Therapy. https://doi.org/10.1016/j.ijrobp.2017.04.024. https://searchnasa.com/record/osti%3A22723019/evaluating-the-toxicity-reduction-with-computed-tomographic-ventilation-functional-avoidance-radiati

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search NASA by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related reports

Cross sections of 147–149 Sm( 6 Li,x) reactions for the production of 149 Tb for targeted alpha therapy

Terbium-149g (t 1/2 = 4.12 h) is of particular interest for targeted alpha therapy cancer treatment due to its ability to decay via both alpha and positron emission, making it a potential theranostic nuclide. Due to many challenges facing its production, there are limited facilities worldwide that have demonstrated the ability to produce this nuclide in quantities sufficient for medical research. Since the Cyclotron Institute at Texas A&M University is a specialized accelerator facility capable of accelerating a wide variety of ions, we are investigating production pathway options. One of the major challenges facing its production is the known co-production of the excited isomeric state, 149m Tb (t 1/2 = 4.1 min). However, this state does not decay to the ground state of 149g Tb, negating any potential contribution to its yield. Due to its short-half life, the cross section for the population of this state has never been measured. After calculating several potential reaction yields using predictive models, the reactions of 147–149 Sm( 6 Li,xn) 149 Tb were identified as candidates. Lithium-6 beams of varied energies between 45-65 MeV were impinged on enriched 147 Sm, 148 Sm, and 149 Sm targets at the Cyclotron Institute at Texas A&M University, and the reaction products were measured immediately following irradiation using high-purity germanium detectors, enabling detection of both 149m Tb and 149g Tb. Cross sections for all nuclides produced in sufficient activity in these reactions were also measured and reported here. We conclude that the population of 149m Tb is much preferred over population of the ground state for these 6 Li-induced reactions, and it is necessary to explore other options for 149g Tb production.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Source function from two-particle correlation function through entropy-regularized Richardson-Lucy deblurring

Source functions are obtained from p – p and d – α correlation functions by applying the Richardson-Lucy (RL) deblurring to the Koonin-Pratt (KP) equation. To prevent fitting of noise in the correlation function, total-variation (TV) regularization is employed that has been effective in ordinary image restoration. TV alone cannot ensure normalization of the source functions. To ensure the latter, we propose a maximum-entropy regularized RL algorithm (MEM-RL). We outline the MEM-RL formalism and optimization strategy for the KP equation, demonstrating its effectiveness on both simulated and experimental data, including the p – p and d – α correlation functions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗