Retractable Sensors for In-Core Service in Material Test Reactors

Abstract

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 – 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 – 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology’s MITR reactor, followed by deployment in an ATR irradiation experiment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Palmer, Joe, Fleming, Austin D, Paulsen, Randel N, Unruh, Troy. 2023-06-12. Retractable Sensors for In-Core Service in Material Test Reactors. https://www.osti.gov/biblio/2278853

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Performance evaluation of neutron noise analysis in detecting special nuclear materials

Reliable and rapid inspection techniques play a vital role in preventing illicit trafficking of special nuclear materials. Active interrogation systems using neutrons produced by portable, high-flux deuterium-deuterium or deuterium-tritium neutron generators are being actively developed as a secondary scanning tool for this purpose. In this study, a neutron noise analysis-based approach for detecting unshielded and shielded special nuclear materials by using a pulsed deuterium-tritium neutron generator was evaluated. Here, this approach analyzes the fluctuation of neutron counts. Its performance was quantified with regard to time-to-detection to achieve a minimum probability of detection of 99% and a probability of false alarm of less than 1% considering various amounts of special nuclear materials and different shielding configurations. It was demonstrated that this approach could detect 17 uranium slugs in 5 s given a neutron generator yield of 8.1 × 10 7 n/s. These slugs could be detected within a reasonable time frame (200 s) when they were shielded by 10.16 cm of high-density polyethylene. The results obtained using the neutron noise analysis approach were compared with those obtained using the commonly used differential die-away analysis technique, a sensitive technique for detecting the presence of fissile materials by utilizing the prompt fission neutrons produced when the source neutrons from a neutron generator are completely diminished. For example, the time to detect 2 unshielded uranium slugs was 2.1 s when using the differential die-away analysis technique; it increased to 93 s for the neutron noise analysis approach. Although the noise analysis-based approach exhibits an overall performance which is not as good as that of differential die-away, neutron noise provides an alternative method for effective detection of special nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A proximity-focusing RICH detector for the ePIC Experiment at the EIC

The Electron-Proton/Ion Collider Experiment (ePIC) will be a large, multi-purpose detector to be installed at the Electron-Ion Collider (EIC) being built at Brookhaven National Laboratory. As robust particle identification (PID) capabilities are essential for fully realizing the EIC science program, ePIC contains several PID subsystems spanning different angular ranges. PID capability in the electron-going endcap is provided by a proximity-focusing Ring Imaging Cherenkov detector (pfRICH) designed to deliver at least 3σ separation between pions and kaons for momenta up to 7 GeV/ c . It will also aid with electron-hadron discrimination at low momentum and assist in the determination of the collision time (t 0 ). This contribution will summarize the design of the pfRICH as well as ongoing fabrication and component testing efforts. geant-based performance simulations will also be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a high voltage delivery system for noble liquid time projection chambers

Noble liquid time projection chambers (TPCs) are a leading technology in the detection of ionizing radiation, particularly in applications such as accelerator neutrino physics, dark matter detection, and neutrinoless double beta decay. This work addresses the design considerations for implementing stable high voltage (HV) systems within large noble liquid TPCs, with a focus on the nEXO experiment. Utilizing insights from prior HV research and experimental investigations, we outline factors influencing HV stability and discuss design choices to improve stability and prevent electrical discharges. A novel HV delivery system concept is presented, tailored for the nEXO TPC, which incorporates these design considerations while also meeting the stringent radiopurity requirements of the nEXO neutrinoless double beta decay search. These design considerations and their specific implementation towards a HV delivery system offer guidance to future experiments applying high voltage in noble liquid environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗