Search NASA⌕ Search

DOE OSTI · 2322504

Advances in mass spectrometry-enabled multiomics at single-cell resolution

Abstract

We report biological organisms are multifaceted, intricate systems where slight perturbations can result in extensive changes in gene expression, protein abundance and/or activity, and metabolic flux. These changes occur at different timescales, spatially across cells of heterogeneous origins, and within single-cells. Hence, multimodal measurements at the smallest biological scales are necessary to capture dynamic changes in heterogeneous biological systems. Of the analytical techniques used to measure biomolecules, mass spectrometry (MS) has proven to be a powerful option due to its sensitivity, robustness, and flexibility with regard to the breadth of biomolecules that can be analyzed. Recently, many studies have coupled MS to other analytical techniques with the goal of measuring multiple modalities from the same single-cell. It is with these concepts in mind that we focus this review on MS-enabled multiomic measurements at single-cell or near-single- cell resolution.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kumar, Rashmi, Zemaitis, Kevin, Fulcher, James M., Pasa-Tolic, Ljiljana. 2024-03-02. Advances in mass spectrometry-enabled multiomics at single-cell resolution. https://doi.org/10.1016/j.copbio.2024.103096

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗