Search NASA⌕ Search

DOE OSTI · 2345165

Geothermal Play Fairway Analysis, Part 2: GIS methodology

Abstract

Play Fairway Analysis (PFA) in geothermal exploration originates from a systematic methodology developed within the petroleum industry and is based on a geologic, geophysical, and hydrologic framework of identified geothermal systems. We tailored this methodology to study the geothermal resource potential of the Snake River Plain and surrounding region, but it can be adapted to other geothermal resource settings. We adapted the PFA approach to geothermal resource exploration by cataloging the critical elements controlling exploitable hydrothermal systems, establishing risk matrices that evaluate these elements in terms of both probability of success and level of knowledge, and building a code-based ‘processing model’ to process results. A geographic information system was used to compile a range of different data types, which we refer to as elements (e.g., faults, vents, heat flow, etc.), with distinct characteristics and measures of confidence. Discontinuous discrete data (points, lines, or polygons) for each element were transformed into continuous interpretive 2D grid surfaces called evidence layers. Because different data types have varying uncertainties, most evidence layers have an accompanying confidence layer which reflects spatial variations in these uncertainties. Risk layers, as defined here, are the product of evidence and confidence layers, and are the building blocks used to construct Common Risk Segment (CRS) maps for heat, permeability, and seal, using a weighted sum for permeability and heat, but a different approach with seal. CRS maps quantify the variable risk associated with each of these critical components. In a final step, the three CRS maps were combined into a Composite Common Risk Segment (CCRS) map, using a modified weighted sum, for results that reveal favorable areas for geothermal exploration. Additional maps are also presented that do not mix contributions from evidence and confidence (to allow an isolated view of evidence and confidence), as well as maps that calculate favorability using the product of components instead of a weighted sum (to highlight where all components are present). Our approach helped to identify areas of high geothermal favorability in the western and central Snake River Plain during the first phase of study and helped identify more precise local drilling targets during the second phase of work. By identifying favorable areas, this methodology can help to reduce uncertainty in geothermal energy exploration and development.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

DeAngelo, Jacob, Shervais, John W., Glen, Jonathan M., Nielson, Dennis, Garg, Sabodh, Dobson, Patrick F., Gasperikova, Erika, Sonnenthal, Eric, Liberty, Lee M., Siler, Drew L., Evans, James P.. 2023-12-04. Geothermal Play Fairway Analysis, Part 2: GIS methodology. https://doi.org/10.1016/j.geothermics.2023.102882

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Technical, economic, and load-following capabilities assessment of grid-connected geothermal and geothermal-solar hybrid systems

The technical and economic performance as well as the load-following capabilities of grid-connected geothermal hybrid systems were assessed in this work. The analyzed geothermal hybrid configuration is composed of a binary geothermal plant integrated with a concentrating solar-thermal system and underground thermal energy storage (UTES) through a primary heat exchanger. Physics-based models for the hybrid system for plant generation capacities of 1, 25, and 50 MW were developed from validated models for each subsystem. Also, an economic model was developed that accounts for different hybrid system capabilities, solar field sizes, and thermal storage duration. The advantage of the geothermal hybrid system was assessed by comparing the performance with the baseline benchmark geothermal plant with a similar configuration and generation capacity. It was found that hybridizing geothermal plants with concentrating solar and thermal energy storage not only improves the thermal efficiency by up to 8 percentage points when additional heat from the solar-UTES loop rises the evaporator temperatures from 70 to 125 °C, but also enhances the load-following capability for the geothermal plant, which can meet a typical residential load profile with a power rate of change 0.25 kW/s with an absolute error under 13 kW for a 1 MW plant. Other benefits of hybridization include resource preservation and a potential LCOE reduction of up to 56% for a 50 MW geothermal hybrid plant having a 50% solar share, a 1.4 solar multiple, and 24-h storage capacity. The results presented in this work demonstrate that hybridizing geothermal systems transforms them into a flexible and cost-effective solution for addressing the dynamic requirements of modern electric grids.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

15 GEOTHERMAL ENERGY↗

Impact of Space Heating Options on Electricity Rates and Affordability

Electricity prices have increased in many regions of the U.S., with a national average of 18 cents/kWh projected for 2026, up from 16 cents/kWh in 2020. While the increases can be attributed to a number of factors, increasing electricity use in an efficient and strategic manner - with energy efficient building envelope upgrades and high performance HVAC systems - has the potential to increase revenue for utilities without significantly increasing electricity demand, and therefore could help moderate rate increases. This effect has been studied for electric vehicle charging[1] and dual-fuel heat pumps in Minnesota[2]. Leveraging a recently developed system cost methodology and FERC data on utility revenue, spending, and profits, this poster will present the direction and relative magnitude of rate impacts for efficient space heating upgrades in utility balancing areas across the contiguous U.S., using current prices and showing how the rate impacts would evolve under future grid scenarios.

15 GEOTHERMAL ENERGY↗