Search NASA⌕ Search

DOE OSTI · 2372864

Capture Cavities for the CW Polarized Positron Source Ce+BAF

Abstract

The initial design of the capture cavities for a continuous wave (CW) polarized positron beam for the Continuous Electron Beam Accelerator Facility (CEBAF) up-grade at Jefferson Lab is presented. A chain of standing wave multi-cell copper cavities inside a solenoid channel are selected to capture positrons in CW mode. The cavity shunt impedance is surveyed by tuning the cavity geometry while considering accommodating large phase space distribution positron beams with large beam pipe radius while ensuring a large enough passband mode separation. The RF field wall loss power and maximum wall loss power density are considered in cavity and waveguide design. A range of design parameters are given for larger system optimization when the capture cavities are considered together with thermal calculation and beam dynamics in next phase of work.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wang, S., Grames, J., Raut, N., Rimmer, R., Roblin, Y., Ushakov, A., Wang, H.. 2024-06-01. Capture Cavities for the CW Polarized Positron Source Ce+BAF. https://doi.org/10.18429/jacow-ipac2024-mopc51