DOE OSTI · 2424784
Open-circuit submodule fault diagnosis in MMCs using support vector machines
Abstract
Series connection of semiconductor submodules (SM) in a modular multilevel converter (MMC) makes the MMC prone to open-circuit (OC) IGBT failures inside SMs. If left undetected, these faults degrade the operation of the MMC and lead to its instability. This article proposes a method to detect, localise, and classify single OC SM faults in an MMC using support vector machines (SVM) trained with data obtained from the capacitor voltage balancing block of the MMC control system. The proposed method relies on data extracted from the sorted capacitor voltage arrays of the upper and lower phase arms. Therefore, it does not require extra measurements and hardware. Additionally, it offers a fixed time for detecting and localising OC SM faults. This method is easy to implement as SVM has a simple decision function. Time-domain simulation case studies are performed on a three-phase nine-level MMC to evaluate the performance of the proposed method.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Mohammadhassani, Ardavan, Mehrizi‐Sani, Ali. 2022-10-29. Open-circuit submodule fault diagnosis in MMCs using support vector machines. https://doi.org/10.1049/gtd2.12652
Cite the original work for its findings. Save a collection to share your selection of sources.