Search NASA⌕ Search

DOE OSTI · 2438484

$\overline{TKE}$ Parameterization and $\bar{v}$ Uncertainty Analysis for CGMF

Abstract

Previous work was performed on tuning CGMF parameters for 235 U, 238 U, and Plutonium isotopes. Now work is being done to tune minor uranium isotopes. However, uranium isotopes like 232 U and 236 U have almost no experimental data. We are applying cross-isotope models to extrapolate and tune CGMF on isotopes that lack experimental data. There exist several internal CGMF physics quantities that affect the output of CGMF—multi-chance fission probability, excitation energy sharing, spin-cutoff factor, spin scaling, and fragment total kinetic energy to name a few. The mean fragment total kinetic energy, $\overline{TKE}$, is particularly interesting because of its strong anti-correlation with $\bar{v}$. We are most interested in the mean fragment total kinetic energy before neutron emissions. $\overline{TKE}$ is assumed to be pre-neutron emission unless otherwise stated. Currently in CGMF, the $\overline{TKE}$ model for 233,234,235,238 U are tuned independently to reproduce ν for the associated isotopes. In this report, we will tune a cross-isotope $\overline{TKE}$ model to experimental $\overline{TKE}$ data for 232,233,234,235,236,238 U. Because of the unreliable and sparse nature of $\overline{TKE}$ experimental data, future work will use more reliable experimental $\bar{v}$ data to infer the $\overline{TKE}$ model (and likely other internal CGMF parameters) for uranium isotopes. Such work has been performed previously using a sensitivity analysis and Kalman filter methods.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Fritsch, William Nicholas, Lovell, Amy Elizabeth, Neudecker, Denise. 2024-07-01. $\overline{TKE}$ Parameterization and $\bar{v}$ Uncertainty Analysis for CGMF. https://doi.org/10.2172/2438484

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Novel Method for Domestic Stable Isotope Production (CRADA #667) Final Report

This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species (35Cl- and 37Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.

07 ISOTOPE AND RADIATION SOURCES↗