Search NASA⌕ Search

DOE OSTI · 2462736

The 4D Camera: An 87 kHz Direct Electron Detector for Scanning/Transmission Electron Microscopy

Abstract

We describe the development, operation, and application of the 4D Camera—a 576 by 576 pixel active pixel sensor for scanning/transmission electron microscopy which operates at 87,000 Hz. The detector generates data at ~480 Gbit/s which is captured by dedicated receiver computers with a parallelized software infrastructure that has been implemented to process the resulting 10–700 Gigabyte-sized raw datasets. The back illuminated detector provides the ability to detect single electron events at accelerating voltages from 30 to 300 kV. Through electron counting, the resulting sparse data sets are reduced in size by 10--300× compared to the raw data, and open-source sparsity-based processing algorithms offer rapid data analysis. The high frame rate allows for large and complex scanning diffraction experiments to be accomplished with typical scanning transmission electron microscopy scanning parameters.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ercius, Peter, Johnson, Ian J., Pelz, Philipp, Savitzky, Benjamin H., Hughes, Lauren, Brown, Hamish G., Zeltmann, Steven E., Hsu, Shang-Lin, Pedroso, Cassio C. S., Cohen, Bruce E., Ramesh, Ramamoorthy, Paul, David, Joseph, John M., Stezelberger, Thorsten, Czarnik, Cory, Lent, Matthew, Fong, Erin, Ciston, Jim, Scott, Mary C., Ophus, Colin, Minor, Andrew M., Denes, Peter. 2024-09-19. The 4D Camera: An 87 kHz Direct Electron Detector for Scanning/Transmission Electron Microscopy. https://doi.org/10.1093/mam%2Fozae086

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗