Search NASA⌕ Search

DOE OSTI · 2496696

Heliostats with Adjustable Shape for High Concentration throughout the Day

Abstract

Our motivation is to develop more efficient heliostats that can provide commercially viable solar thermal power at temperatures > 800°C. Such high temperatures will enable high-temperature industrial processes, as well as electrical generation after sunset with high efficiency. The importance of this research is that such heliostats have the potential to substantially expand the global use of solar energy, by adding solar thermal power as a major component. Thermal solar currently accounts for only 1% of all solar power (with PV being the rest), with heliostat fields providing just 0.25%. Our goals have been 1) to demonstrate a technical improvement for heliostats that can enable fields of them to more efficiently power receivers and reactors, and 2) to show a path to low-cost mass production. Our solution uses new opto-mechanical technology to correct a fundamental deficiency of present heliostats that limits their concentration, namely that they have fixed shape. Most of today’s heliostat research does not address this, but is directed simply toward cost reduction in an effort to make heliostats commercially viable. We are motivated to explore also improving heliostat efficiency, which can be done by continually changing their shape to maximize the concentration of sunlight throughout the day. This is not a new concept, but it has never been implemented in a practical, cost-effective way that approaches the theoretical limit to concentration while also improving mechanical performance; this is our goal. Our major accomplishments have been: 1) We have realized the planned design, construction, and test of a prototype heliostat that achieves the required shape changes in an 8 m2 single-piece glass mirror. The mirror is attached to a steel support frame that is automatically mechanically twisted by the heliostat drives that orient the mirror to direct sunlight to the tower-mounted receiver. Closed-loop tracking is done using a new beamsplitter camera that exploits the target-oriented mount configuration. Field tests of the heliostat show that the light is reflected through the day to always form a disc image of the sun, as needed to obtain the highest concentration. 2) We have developed the design for a field of 431 heliostats to deliver annual average of 1 MW of thermal power at 3,000 sun concentration, matched to a high-temperature ≥ 1000°C chemical reactor. 3) We have also developed, beyond the original stated goals of the project, a new concept for closed-loop tracking and shape-sensing for all the heliostats in the above field, using just 6 cameras around the concentrated reactor focus. Our research adds to the understanding of solar thermal energy by its demonstration of the technical effectiveness of a higher performing heliostat, and by its concept for a new powerful method for real-time tracking and shape sensing in the field, as described above. We have studied the economic feasibility of fields of our twisting heliostats to provide high- temperature heat at a price competitive with that of burning gas, to satisfy the DOE’s studied zero-emissions scenario, where the gas price has to include the cost of carbon capture. The project has the potential to greatly benefit the public if it helps limit global warming by 1) reducing carbon emission from industrial heating, which is currently a major contributor to the 40-billion-ton annual increase in atmospheric CO 2 . 2) Ultimately, the technology could prove to be the least expensive method to power direct air capture of CO 2 on the very large scale needed to remove the 1 trillion-ton excess of CO 2 already in the atmosphere.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Angel, James Roger Prior, Kim, Daewook, Li, Peiwen, Choi, Heejoo, Kang, Hyukmo, Rademacher, Matthew, Didato, Nick, Vagher, Andrew, Huang, Yiyang, Hernandez, Mitchell. 2024-11-26. Heliostats with Adjustable Shape for High Concentration throughout the Day. https://doi.org/10.2172/2496696

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Heliostat sizing methodology for concentrating solar thermal industrial process heat projects

This study presents a method to obtain a heliostat size that minimizes the levelized cost of heat (LCOH) of a heliostat-based concentrating solar thermal system for applications of solar heating for industrial processes at operating temperatures from 565 to 1550°C. The method extends prior work by embedding a routine for system design that obtains near-optimal subsystem sizes, increasing the fidelity of drive cost functions, and adding an optical performance model to supplement the previously developed cost models, which we update to reflect current pricing trends. An illustrative business case is developed for Daggett, California, targeting specified annual thermal energy outputs of 50 to 400 GWh th . Optical performance is modeled using verified estimates from the literature. A surrogate heliostat cost model, derived from commercial heliostat designs and scaled for production volume, installation, and operations and maintenance costs, is used to develop cost functions. Results show that heliostat size strongly affects the LCOH, producing a characteristic U-shaped trend with a robust near-optimal window of 7-20 m 2 ; the heliostat size producing the lowest project cost in our study grows slightly as the project size increases, and is reduced as the operating temperature increases. The findings in this study are consistent with the general trend of smaller heliostats being deployed at existing projects for high-temperature industrial process heat and reflect the significant reduction in power electronics and other per-heliostat costs. The methodology we propose is general and can be tailored to revised cost curves as the technology continues to evolve.

14 SOLAR ENERGY↗

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY↗

Technoeconomic Analysis Round Robin of a Retrofit of the Ivanpah Concentrating Solar Plant with a Molten-Salt System with Thermal Energy Storage

While the fidelity of technoeconomic analysis (TEA) models for concentrating solar thermal systems has improved in recent years, there is a lack of consensus on the specific inputs used to forecast performance of a newly built tower system due to a lack of validations and post-mortems available to the public. This effort is a joint initiative between multiple international organizations to validate and compare their TEA models. The specific case study is a proposed retrofit of one unit of the Ivanpah Solar Energy Generating System to include molten-salt storage, replacing the steam generation system with a molten-salt receiver, salt-to-steam heat exchanger train, and new balance of plant while keeping the existing steam turbine, solar field, and interconnection in place, using plant data for calibration. This manuscript discusses several of the agreed-upon assumptions for this study as well as a preliminary analysis from prior work that motivates the study.

14 SOLAR ENERGY↗