Search NASA⌕ Search

DOE OSTI · 2500779

AstroPix4 — a novel HV-CMOS sensor developed for space based experiments

Abstract

For the proposed space based gamma-ray observatory All-sky Medium-Energy Gamma-ray Observatory eXplorer (AMEGO-X), a silicon tracker based on a novel High Voltage-CMOS (HV-CMOS) sensor called AstroPix, is currently being developed. Preliminary measurements with the first full reticle prototype AstroPix3 show that the power target of 1.5 mW/cm 2 can currently not be reached due to the digital consumption of 3.08 mW/cm 2 , while the analog power consumption of 1.04 mW/cm 2 and a break down voltage of over 350 V look promising. Based on these results, the design changes in AstroPix4, submitted in May 2023, are presented, containing changes to the time stamp generation and readout architecture. A digital power consumption below 0.25 mW/cm 2 is expected by removing the fast 200 MHz clock used to measure the time-over-threshold (ToT) and an LVDS receiver. A maximum resolution of 3.125 ns for time-of-arrival (ToA) and ToT is reached by adding per-pixel Flash-Time-to-Digital Converter (TDCs) controlled by a global delay-locked loop (DLL).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Striebig, N., Leys, R., Peric, I., Caputo, R., Steinhebel, A. L., Suda, Y., Fukazawa, Y., Jadhav, M., Violette, D., Kierans, C., Tajima, H., Metcalfe, J., Perkins, J. S.. 2024-04-03. AstroPix4 — a novel HV-CMOS sensor developed for space based experiments. https://doi.org/10.1088/1748-0221%2F19%2F04%2Fc04010

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗