Lithium isotopic analysis in depleted lithium salts

Abstract

Lithium isotope separation processes require characterization of the isotopic compositions of the different output phases of the process. While considerable effort to develop isotope separation methods has been ongoing for decades, the analytical methods associated with these analyses are rarely provided. Here, in this work three types of mass spectrometers (Q-ICP-MS, MC-ICP-MS, TIMS) were tested for the ability to measure depleted lithium salts that are relevant materials for isotopic separations. Results indicate that, once stabilized, the Q-ICP-MS can provide equal precision for Li isotopic samples compared to TIMS or MC-ICP-MS. However, MC-ICP-MS consistently provides the highest precision for salts across both depleted and natural isotopic abundances. These data demonstrate that Q-ICP-MS is an appropriate choice for analysis of depleted lithium salts, especially when rapid analyses are desired for online process monitoring.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hobbs, Kirby [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)], Scott, Sean R. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)] (ORCID:0000000336974635), Williams, Johnny [Kairos Power, Alameda, CA (United States)], Mastromarino, Sara [Kairos Power, Alameda, CA (United States)], Gajos, Norbert [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)], Berry, Christian [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)], Anderson, Ian [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)], Melby, Kali [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)], Kruizenga, Alan [Kairos Power, Alameda, CA (United States)]. 2025-02-21. Lithium isotopic analysis in depleted lithium salts. https://doi.org/10.1016/j.pnucene.2025.105674

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Novel Method for Domestic Stable Isotope Production (CRADA #667) Final Report

This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species (35Cl- and 37Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.

07 ISOTOPE AND RADIATION SOURCES↗