Abstract
Insertion Device (ID) Group at the National Synchrotron Light Source-II (NSLS-II) has been involved in the following activities: Installation and maintenance of the HEX-Superconducting Wiggler (SCW), Laboratory Directed Research and Development (LDRD) for SC adaptive gap undulator (AGU), NSLS-II Experimental Tools II & III (NEXT-II & III) project IDs. Improvement of in-vacuum flip coil bench, development of in-vacuum pulsed wire bench and upgrade of a regular flip coil bench. Development of rotating coil bench for the lattice magnets for future upgrade. This paper describes the specifics of each activity.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Tanabe, T [Brookhaven National Laboratory (BNL), Upton, NY (United States)] (ORCID:0000000271884080), Hidas, D [Brookhaven National Laboratory (BNL), Upton, NY (United States)], Musardo, M [Brookhaven National Laboratory (BNL), Upton, NY (United States)], Rank, J [Brookhaven National Laboratory (BNL), Upton, NY (United States)], Eipper, B [Brookhaven National Laboratory (BNL), Upton, NY (United States)], Brookbank, T [Brookhaven National Laboratory (BNL), Upton, NY (United States)], Holland, B [Brookhaven National Laboratory (BNL), Upton, NY (United States)], Migliorino, D [Brookhaven National Laboratory (BNL), Upton, NY (United States)]. 2025-06-05. Recent activities of National Synchrotron Light Source-II Insertion Device Group. https://doi.org/10.1088/1742-6596%2F3010%2F1%2F012006
Cite the original work for its findings. Save a collection to share your selection of sources.