Search NASA⌕ Search

DOE OSTI · 2578426

Studying fast-ion populations using oscillations in solid-state neutral-particle analyzer signal and neutral-beam injection power

Abstract

A method for determining the fast-ion population density in magnetically confined plasmas as a function of pitch-radius, (λ, R), using a solid-state neutral-particle analyzer (ssNPA) signal and neutral-beam injection (NBI) power-output data has been developed. Oscillations in the NBI power output are replicated only in the active part of the ssNPA signal, allowing this to be separated from the passive and background signals, which usually complicate data from this diagnostic. Results obtained using this method are compared with those from standard techniques using data from the Mega-Amp Spherical Tokamak Upgrade spherical tokamak.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Parr, E. (ORCID:0000000162044461), McClements, K. (ORCID:000000025162509X), Heidbrink, W. (ORCID:0000000269428043), Michael, C. (ORCID:000000031804870X), Prechel, G. (ORCID:0000000163396055), Rivero-Rodriguez, J. (ORCID:0000000150740267). 2024-01-01. Studying fast-ion populations using oscillations in solid-state neutral-particle analyzer signal and neutral-beam injection power. https://doi.org/10.1063/5.0178179

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Noncontact excitation of multi-GHz lithium niobate electromechanical resonators

Abstract The demand for high-performance electromechanical resonators is ever-growing across diverse applications, ranging from sensing and time-keeping to advanced communication devices. Among the electromechanical materials being explored, thin-film lithium niobate stands out due to its strong piezoelectric properties and low acoustic loss. However, in nearly all existing lithium niobate electromechanical devices, the configuration is such that the electrodes are in direct contact with the mechanical resonator. This configuration introduces an undesirable mass-loading effect, producing spurious modes and additional damping. Here, we present an electromechanical platform that mitigates this challenge by leveraging a flip-chip bonding technique to separate the electrodes from the mechanical resonator. By offloading the electrodes from the resonator, our approach yields a substantial increase in the quality factor of these resonators, paving the way for enhanced performance and reliability for their device applications.

Instruments & Instrumentation↗