Abstract

This study investigates three mounting methods—clamping, soldering, and a hybrid clamping–soldering approach—for cryogenically cooled thin diamond crystals crucial to stable operation of X-ray Free Electron Laser (XFEL) systems. While clamping methods exhibit temperature resilience and flexibility, meticulous design is required to prevent stress-induced warping and reduce thermal contact area. Soldering methods offer reliable mechanical and thermal bonding but encounter challenges due to the coefficient of thermal expansion mismatch at cryogenic temperatures. The hybrid method, integrating clamping and soldering with strain relief cuts, effectively mitigates overall distortion caused by mounting and XFEL thermal loads. These findings offer a novel mounting solution for high-performance x-ray optics in XFEL research and applications, ensuring stability and optimal functionality in cryogenic conditions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Qu, Zhengxian (ORCID:0000000264089644), Ma, Yanbao (ORCID:0000000197213333), Wu, Juhao (ORCID:0000000315425688). 2024-05-01. Exploring mounting solutions for cryogenically cooled thin crystal optics in high power density x-ray free electron lasers. https://doi.org/10.1063/5.0191095

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Noncontact excitation of multi-GHz lithium niobate electromechanical resonators

Abstract The demand for high-performance electromechanical resonators is ever-growing across diverse applications, ranging from sensing and time-keeping to advanced communication devices. Among the electromechanical materials being explored, thin-film lithium niobate stands out due to its strong piezoelectric properties and low acoustic loss. However, in nearly all existing lithium niobate electromechanical devices, the configuration is such that the electrodes are in direct contact with the mechanical resonator. This configuration introduces an undesirable mass-loading effect, producing spurious modes and additional damping. Here, we present an electromechanical platform that mitigates this challenge by leveraging a flip-chip bonding technique to separate the electrodes from the mechanical resonator. By offloading the electrodes from the resonator, our approach yields a substantial increase in the quality factor of these resonators, paving the way for enhanced performance and reliability for their device applications.