The motional Stark effect diagnostic for ITER

Abstract

An overview of the plans for the motional Stark effect (MSE) diagnostic installation on the International Thermonuclear Experimental Reactor (ITER) is presented. The MSE diagnostic uniquely provides spatially localized magnetic field measurements inside the plasma. These are used to constrain equilibrium reconstructions to determine q(r), the safety factor as a function of minor radius. Meeting the system requirements to deliver q-profiles and related quantities with the specified radial resolution of 20 points over the minor radius, 10 ms time resolution, and better than 10% accuracy is challenging. MSE systems observe the D/H-α emission near 656.3 nm from neutral beams. As the beam atoms traverse the magnetic field, B⃗, at high velocity, v⃗, they experience a Lorentz electric field, v⃗×B⃗, which causes the spectral emission to be split and polarized due to the Stark effect. Traditional MSE-LP (line polarization) measurements determine the direction of the magnetic field in the observation volume using polarimetric analysis of the detected light. The harsh conditions of ITER are expected to deposit thin films of contaminants on the first mirror, which would alter the polarization state of reflected light significantly. On ITER, the combination of high magnetic field strength and high energy beams makes the Stark spectrum resolution suitable for the determination of the magnetic field magnitude from the line shift, so this approach has been selected. Every aspect of the measurement system must be planned for the burning plasma environment and carefully analyzed ahead of time. Current status and plans for the system are presented.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Foley, E. (ORCID:0009000317528397), Levinton, F. (ORCID:0009000122847881), Uzun-Kaymak, I. (ORCID:0000000276251493), Galante, M. (ORCID:0009000098149425), Zhang, X. (ORCID:0009000455003839). 2024-07-01. The motional Stark effect diagnostic for ITER. https://doi.org/10.1063/5.0215575

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Noncontact excitation of multi-GHz lithium niobate electromechanical resonators

Abstract The demand for high-performance electromechanical resonators is ever-growing across diverse applications, ranging from sensing and time-keeping to advanced communication devices. Among the electromechanical materials being explored, thin-film lithium niobate stands out due to its strong piezoelectric properties and low acoustic loss. However, in nearly all existing lithium niobate electromechanical devices, the configuration is such that the electrodes are in direct contact with the mechanical resonator. This configuration introduces an undesirable mass-loading effect, producing spurious modes and additional damping. Here, we present an electromechanical platform that mitigates this challenge by leveraging a flip-chip bonding technique to separate the electrodes from the mechanical resonator. By offloading the electrodes from the resonator, our approach yields a substantial increase in the quality factor of these resonators, paving the way for enhanced performance and reliability for their device applications.

Instruments & Instrumentation↗