Charge collection efficiency of diamond and silicon sensors irradiated with alpha particles

Abstract

To evaluate the viability of using semiconductors as sensor materials in a detector for the Associated Particle Imaging technique, the radiation hardness of silicon and diamond diodes to alpha particles has been assessed. Here, the detector lifetimes for both silicon and diamond sensors were measured under the prolonged exposure to alpha particles emitted by an 241 Am source. The silicon detector was exposed to alpha radiation for approximately two months, reaching an accumulated fluence of ~ 1.5 x 10 12 α cm –2 . Additionally, by using a high purity single-crystal diamond with coplanar electrodes operating with full charge collection, the diamond detector response was measured over approximately ten months reaching an accumulated fluence of over 6 x 10 12 α cm –2 cm.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Muller, Erik M. [Brookhaven National Laboratory (BNL), Upton, NY (United States)] (ORCID:0000000339339602), Carini, Gabriella A. [Brookhaven National Laboratory (BNL), Upton, NY (United States)], Fabris, Lorenzo [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)] (ORCID:0000000156055615), Giacomini, Gabriele [Brookhaven National Laboratory (BNL), Upton, NY (United States)] (ORCID:0000000200710841), Kierstead, James [Brookhaven National Laboratory (BNL), Upton, NY (United States)], McConchie, Seth M. [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)] (ORCID:0000000308910503), Pinelli, Donald A. [Brookhaven National Laboratory (BNL), Upton, NY (United States)], Rescia, Sergio [Brookhaven National Laboratory (BNL), Upton, NY (United States)], Rossi, Enrico [Brookhaven National Laboratory (BNL), Upton, NY (United States)]. 2025-07-07. Charge collection efficiency of diamond and silicon sensors irradiated with alpha particles. https://doi.org/10.1016/j.nimb.2025.165778

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION