Search NASA⌕ Search

DOE OSTI · 2999942

Earthquake detection in a simulated lunar regolith using distributed acoustic sensing

Abstract

Current models of inner lunar geology have largely been inferred from the seismic experiments and observations performed during the Apollo missions that comprised a relatively small number of seismic instruments. Refining constraints on fundamental lunar relationships such as crust-mantle and mantle-core boundaries in the future will require seismic arrays spanning larger epicentral distances. A promising technology for installing dense seismic arrays with minimal human effort is distributed acoustic sensing (DAS), an approach that allows a single length of fiber optic cable to act as hundreds or thousands of sensors when coupled with a DAS interrogator. While terrestrial uses of DAS technology for seismic monitoring rely on burying the cable to maximize fidelity of seismic signal transmission to the fiber, digging meters of trench to bury optical fiber on lunar or planetary surfaces is logistically infeasible. To evaluate DAS signal attenuation due to surface deployment of cable in lunar regolith, we completed earthquake detection analyses that evaluated the sensitivity of an optic-fiber DAS system to seismic signals at different burial depths. We deployed a single-mode fiber in a 10-m open-bottom wooden box filled with a lunar regolith simulant (LRS) with fiber buried at different depths within the LRS and recorded signals for four regional and local earthquakes. The results were used to identify and evaluate signal attenuation in surface-deployed fiber compared to buried fiber in the LRS. Burial depth responses to active-source signals were also evaluated similar to previous studies characterizing DAS sensitivity of surface-deployed fiber. Atmospheric noise was minimal as the cable was deployed in an indoor environment; however, where observed, atmospheric and anthropogenic noise was filtered out using the same bandpass filtering used to identify earthquake events. We found that signal attenuation of the surface-deployed fiber compared to buried fiber was relatively high in active-source experiments but was not consistently observed in earthquake signals. That burial depth is not highly correlated to attenuation of the observed earthquake signals indicates that in a noise-limited environment, placing DAS-interrogated fiber directly at the regolith surface may be a promising deployment strategy to consider for sensing remote seismic signals during lunar exploration.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zandanel, Amber Elizabeth [Los Alamos National Laboratory (LANL), Los Alamos, NM (United States); Geologic Materials Center, Anchorage, AK (United States)] (ORCID:0000000209400751), Gao, Kai [Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)] (ORCID:0000000232808181), Probst, Simone [Eidgenoessische Technische Hochschule (ETH), Zurich (Switzerland)], Robertsson, Johan O.A. [Eidgenoessische Technische Hochschule (ETH), Zurich (Switzerland)], Donahue, Carly Michelle [Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)] (ORCID:0000000223323924). 2025-10-11. Earthquake detection in a simulated lunar regolith using distributed acoustic sensing. https://doi.org/10.1016/j.icarus.2025.116848

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Spectrophotometric study of erbium (III) speciation in chloride solutions from 25 to 75 °C

In this study, UV-Vis spectrophotometric experiments were conducted from 25 to 75 °C using Er-HClO4-bearing solutions with varying NaCl concentrations. The molar absorbance coefficient of Er3+ decreases with temperature, and the absorbance intensity gradually decreases with increasing mCl/mEr ratios. The number of absorbing species include Er3+ and ErCl2+ even at the highest mCl/mEr ratio. The formation constant (β 1 ) for the ErCl 2+ species was derived and fitted between 50 and 250 °C with existing literature values, yielding the following equation: logβ 1 0 = −22.4315 + 0.0345T + 3.9379·10 3 /T, where T is temperature in Kevin.

58 GEOSCIENCES↗

The future of subsurface monitoring: AEC’s breakthroughs in CCS technology

Carbon capture and storage (CCS) has emerged as a key solution in the fight against climate change. However, for CCS to succeed, it is crucial to ensure that the sequestered CO2 stays safely trapped underground. The U.S. Department of Energy (DOE) has emphasized the need for advancements in subsurface monitoring, measurement, reporting, and verification. Aside from caprock integrity failure, the other primary failure points usually involve defective cement in the casing annulus of wellbores or plugged and abandoned wells. In addition, many energy producers (e.g., oil and gas, geothermal) and storage and disposal operators (e.g., H2 and water) must deal with the same issue. Poorly placed or degraded cement can create pathways for gas or fluid to escape from casing annuli and in plugged and abandoned or orphan wells, posing environmental risks. Yet, a reliable and cost-effective way to monitor cement and well integrity over multiple decades is still unavailable. Traditional geophysical methods like 4D seismic imaging and surface-based electromagnetic monitoring lack the resolution and accuracy for detecting these types of failures (Vasco et al., 2022; Fawad and Mondol, 2021). Wireline logging is expensive to run continuously and is obtrusive to the operation. While fiber optics can potentially be a solution, its bulkiness can significantly compromise the cement's integrity. To address these challenges, the Advanced Energy Consortium (AEC) at The University of Texas at Austin’s Bureau of Economic Geology (the Bureau) has been pioneering research in subsurface monitoring using its portfolio of distributed autonomous microfabricated sensors for harsh subsurface environments since 2008. A class of these microsensors [System on a Chip (SoC)] can be mixed in cement and permanently placed without compromising the cement column; the sensors would then communicate with each other or a data acquisition (DAQ) master node. Another class of the AEC microsensors can be fully autonomous, with rechargeable micro-batteries capable of exceeding 100°C, flash memory, and, currently, a pressure and temperature sensor. They are designed to circulate in mud, geothermal fluids, U-loops, or pipelines. They can log data into memory and are unobtrusive to operations. Our team has been working on a multi-year DOE-funded project (DE-FE0031856)—supported by $2.95M in federal funding and $0.75M in cost-matching from the AEC—to demonstrate SoC sensor utility for CO2 leakage monitoring in CCS applications. This multi-institutional collaboration developed a novel sensing architecture utilizing radiofrequency (RF) microsensors embedded within the cement sheath. These sensors detect CO2 migration and are interrogated via a Smart Casing Collar (SCC).

58 GEOSCIENCES↗

Hydrogeological assessment of CO2 containment assurance and wellbore integrity at a Gulf Coast storage site

Abstract A large-scale carbon capture and storage (CCS) initiative on the Texas Gulf Coast serves as a premier demonstration of the U.S. Department of Energy’s CarbonSAFE program. Targeting deep saline formations, specifically Oligo-Miocene deltaic sequences, the project aims to establish technical and commercial viability for geologic CO2 storage within a major industrial corridor. This study provides a rigorous hydrogeological assessment to support Class VI permitting by quantifying the high degree of containment security. Utilizing a compositional reservoir simulator, we developed a suite of 27 distinct simulation cases to evaluate vertical plume dynamics near both planned injection wells and proximal legacy infrastructure. To ensure numerical accuracy near wellbores, we implemented a refined mesh strategy, determining that a 5.6 ft × 5.6 ft grid refinement offered the optimal balance between computational efficiency and descriptive precision. The modeling framework utilized a systematic sensitivity-based approach to evaluate the mechanical redundancy of the subsurface system by performing a bounding analysis of wellbore interfaces against hypothetical high-permeability microannuli. By systematically isolating competing physical drivers, including permeability, porosity, gas hysteresis, thermal gradients, salinity, and solubility trapping (quantified via Henry’s law with dynamically adjusted coefficients), this work moves beyond binary assessments to establish a nuanced hierarchy of containment factors. The results confirm that primary trapping mechanisms (e.g., gas hysteresis and solubility), combined with the site's unique geomechanical stratigraphy, significantly restrict vertical mobility and reinforce the robust containment security of the reservoir. Baseline results demonstrate substantial vertical separation between the CO2 plume and the upper confining system, ensuring robust containment. Sensitivity analysis reveals that even under highly conservative bounding scenarios—assuming theoretical 10-Darcy pathways at specific wellbore locations—the 2,900-ft thick multi-layered confining zone remains a reliable barrier. In these hypothetical upper-bound cases, peak upward fluxes of CO2 and saltwater after 15 years of injection remain localized and dissipate rapidly within the lower sections of the confining interval, leaving the integrity of the seal uncompromised. Furthermore, the study identifies that while localized wellbore pathways define theoretical upper bounds of vertical migration, the Area of Review (AoR) is primarily sensitive to regional thermal gradients and hysteresis, which can influence the AoR by over 3,000 acres in pessimistic configurations. Also, primary trapping mechanisms, specifically gas hysteresis and solubility, work in tandem with the Gulf Coast’s unique geomechanical stratigraphy to significantly restrict vertical mobility. Ductile, smectite-rich mudstones facilitate natural borehole convergence and the self-healing of potential conduits, creating a natural geomechanical bridge that effectively mitigates migration potential at both current injection points and legacy-well locations. This comprehensive modeling effort demonstrates that the integration of high-resolution wellbore simulations and regional geomechanical observations confirms the long-term storage security of the studied site, providing a physics-based foundation for industrial-scale CCS deployments. This modeling framework establishes a baseline for future research into coupled geomechanical effects, such as time-dependent borehole convergence, to further refine long-term containment projections. Acknowledgements We thank the Gulf Coast Carbon Center (GCCC) at the Bureau of Economic Geology for foundational research support. We appreciate Alex Bump for technical guidance and David Hoffman for model mesh generation. This work used TACC’s Frontera cluster for simulations and CMG Ltd. software licenses provided to UT-Austin. This material is based upon work supported by the Department of Energy under Award Number DE-FE0032338. Disclaimer This material is based upon work supported by the U.S. Department of Energy’s Fossil Energy and Carbon Management Office under the CarbonSAFE program, award Number DE-FE0032338. The views expressed herein do not necessarily represent the views of the U.S. Department of Energy or the United States Government.

58 GEOSCIENCES↗