Abstract
X-ray radiography can be an important diagnostic for emergency response, providing timely diagnostic information about a suspect object. However, there are situations where similar information would be better obtained with a one-sided imaging technique. X-ray backscatter imaging is a proven technology that could provide such information, but current implementations have drawbacks that render it unsuitable for emergency response. We are exploring the use of coded-aperture imaging to create one-sided images, targeting a key benefit: implementation requiring minimal additional resources, bypassing logistics issues. We present results demonstrating the feasibility of this approach.
Keep this discovery
Explore connections, maps & timelines
Ziock, Klaus-Peter [ORNL], Biladeau, Kyndal [University of Tennessee (UT)], Hayward, Jason [University of Tennessee, Knoxville (UTK)], Laminack, Alex [ORNL] (ORCID:0000000251664523), Misurek, Lauren [Los Alamos National Laboratory (LANL)], Rose Jr, Paul [ORNL] (ORCID:0000000296115085), Schmitt, Kyle [ORNL], Winch, Nicola [Los Alamos National Laboratory (LANL)]. 2025-08-01. Whole-scene, one-sided backscatter x-ray imaging with coded apertures. https://www.osti.gov/biblio/3002312