Search NASA⌕ Search

DOE OSTI · 3011092

Particle hit clustering and identification using point set transformers in liquid argon time projection chambers

Abstract

Liquid argon time projection chambers are often used in neutrino physics and dark-matter searches because of their high spatial resolution. The images generated by these detectors are extremely sparse, as the energy values detected by most of the detector are equal to 0, meaning that despite their high resolution, most of the detector is unused in a particular interaction. Instead of representing all of the empty detections, the interaction is usually stored as a sparse matrix, a list of detection locations paired with their energy values. Traditional machine learning methods that have been applied to particle reconstruction such as convolutional neural networks (CNNs), however, cannot operate over data stored in this way and therefore must have the matrix fully instantiated as a dense matrix. Operating on dense matrices requires a lot of memory and computation time, in contrast to directly operating on the sparse matrix. We propose a machine learning model using a point set neural network that operates over a sparse matrix, greatly improving both processing speed and accuracy over methods that instantiate the dense matrix, as well as over other methods that operate over sparse matrices. Compared to competing state-of-the-art methods, our method improves classification performance by 14%, segmentation performance by more than 22%, while taking 80% less time and using 66% less memory. Compared to state-of-the-art CNN methods, our method improves classification performance by more than 86%, segmentation performance by more than 71%, while reducing runtime by 91% and reducing memory usage by 61%.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Robles, Edgar E. [Univ. of California, Irvine, CA (United States)] (ORCID:0000000161283268), Yankelevich, Alejandro [Univ. of California, Irvine, CA (United States)] (ORCID:0000000259633123), Wu, Wenjie [Univ. of California, Irvine, CA (United States)] (ORCID:0000000343799548), Bian, Jianming [Univ. of California, Irvine, CA (United States)] (ORCID:0000000337395424), Baldi, Pierre [Univ. of California, Irvine, CA (United States)] (ORCID:0000000187524664). 2025-07-16. Particle hit clustering and identification using point set transformers in liquid argon time projection chambers. https://doi.org/10.1088/1748-0221%2F20%2F07%2Fp07030

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Introducing a Markov chain-based time calibration procedure for multi-channel particle detectors: application to the SuperFGD and ToF detectors of the T2K experiment

Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed must be able to efficiently correct for minimal mis-synchronisation between channels and achieve the best detector performance. We present an iterative time calibration method based on Markov Chains, suitable for detector systems with multiple readout channels. Starting from correlated hit pairs alone, and without requiring an external reference time measurement, the method solves for fixed per-channel offsets, with precision limited only by the intrinsic single-channel resolution. A mathematical proof that the method is able to find the correct time offsets to be assigned to each detector channel in order to achieve inter-channel synchronisation is given, and it is shown that the number of iterations to reach convergence within the desired precision is controllable with a single parameter. Numerical studies are used to confirm unbiased recovery of true offsets. Finally, the application of the calibration method to the Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF) detector at the upgraded T2K near detector (ND280) shows good improvement in overall timing resolution, demonstrating the effectiveness in a real-world scenario and scalability.

calibration and fitting methods↗