Abstract

There is growing interest in energy storage technologies due to the expansion of renewable energy sources that are inherently intermittent and the increasing frequency of extreme weather events that disturb the power grid. Power consumption in buildings makes up approximately 76% of all electricity usage on the grid and is primarily used for thermal applications such as space conditioning, hot water, and cooking. This makes thermal energy storage (TES) an ideal solution for many of these applications. Many TES technologies rely on latent energy storage, which utilizes the melting/solidification of phase change materials (PCM) to store energy. Typically, TES designs suffer from low power density due to their low inherent thermal conductivity. This limitation makes the deployment of TES in active applications difficult as the ease of access to energy is essential for effective use. Common routes for improving power density include high thermal conductivity additives or extended features such as fins that increase cost. This study presents an alternative approach to improving performance through increasing the overall surface area to volume ratio of the device, to increase the available area for convection to occur between the working fluid and PCM. In the study a commercial PCM was selected with a transition temperature ideal for space heating applications. The heat exchanger design utilizes a unique application of triply periodic minimal surfaces (TPMS) for macro-encapsulation of the PCM. The use of TPMS for heat exchangers has been growing in interest due to their high-surface area to volume ratios, which were previously unmanufacturable until the development of additive manufacturing. A modular system was designed and manufactured with a stereolithography resin printing system that is then backfilled with PCM. An experiment test set-up is designed to test the charge and discharge performance of the thermal storage using a conditioned air stream. The pressure drop of the design is tested across a variety of flow rates. When compared to existing experimental data within literature, there is excellent agreement based on the Reynolds number at similar hydraulic diameters. Several inlet temperatures are tested at consistent temperature differences from the phase change temperature for both charging and discharging. Additionally, the volumetric flow rate is varied for each temperature set point. It was found that increasing flow rate had diminishing returns in reducing the overall charge time of the TES. The temperature delta from the melting temperature was the primary contributor to the change in average heat flux with limited variation in average heat transfer rate between charging and discharging at similar inlet temperatures and flow rates. The TPMS heat exchanger design has a high air-side pressure drop but it provides high heat transfer rates. This helps maintain a high outlet temperature during discharge, which is important to thermal comfort applications. The design, manufacturing, and experimental characterization of the TES device will be presented as part of this study.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Troxler, Casey [Embry-Riddle Aeronautical University], Freeman, Thomas [National Renewable Energy Lab., Golden, CO (United States)], Morgan, Karl [Embry-Riddle Aeronautical University], Odukomaiya, Adewale [National Renewable Energy Lab., Golden, CO (United States)] (ORCID:0000000295609964), Boetcher, Sandra [Embry-Riddle Aeronautical University]. 2025-11-24. Experimental Characterization of High-Surface Area Thermal Energy Storage. https://doi.org/10.2172/3013229

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

An immersed interface method for microstructure-scale electrochemical battery models: numerical formulation and performance portable implementation

We present the numerical formulation, verification, and performance portable implementation of an immersed interface method for microstructure scale electrochemical modeling of batteries. The innovation in this approach is the resolution of chemical species and electrostatic potential discontinuities at active interfaces without the use of interface conforming unstructured grids. A unified formulation on Cartesian grids for all domains (electrodes and electrolyte) is used with interfacial flux conditions applied using volume fraction or “color” function gradients. We have developed one dimensional and two dimensional test cases with analytic solutions for electrochemical modeling using which we verified the consistency and accuracy of our scheme. Our solver is also validated against solutions from a macroscale model and an unstructured multi-subdomain solver for a full lithium ion cell. We then demonstrated the utility of our solver on an image-based complex battery electrode microstructure at high charging rate. Our technique also exhibits good scalability on distributed memory architectures using central processing units (CPU), with problem sizes up to 1.8 billion degrees of freedom and with 5400 ranks. Initial performance studies of our open-source performance portable solver showed about 70 times speed up using a graphics processing unit (GPU) compared to single compute core for a problem with 4 million cells.

25 ENERGY STORAGE↗

Solvation-guided inhibition of manganese dissolution of lithium- and manganese- rich cathode via cyclic carbonate molecular engineering

Lithium and manganese-rich (LMR) layered oxides represent a leading class of high-energy cathode materials, but their practical realization is fundamentally limited by severe manganese (Mn) dissolution, a process that triggers structural degradation and rapid capacity fade. While mitigation efforts have predominantly focused on interfacial engineering, the intrinsic contribution of bulk electrolyte solvation to this degradation pathway remains largely unexplored, primarily due to the difficulty of deconvolving its effects from concurrent cathode-electrolyte interphase (CEI) formation. Here, we report an experimental design to isolate the role of solvation. We systematically varied the electrolyte solvent solvation power by substituting the strongly coordinating ethylene carbonate (EC) with its weaker coordinating fluorinated derivatives, fluoroethylene carbonate (FEC) and trans-4,5-Difluoro-1,3-dioxolan-2-one (DFEC), while maintaining a consistent interfacial chemistry. Remarkably, the electrolyte formulated with the weakest solvent, DFEC, exhibits superior cycling stability, suppressing Mn dissolution by up to 63% relative to the conventional EC-based system. Post-mortem analysis unequivocally attributes this performance enhancement to the preservation of the LMR cathode's structural integrity, a direct consequence of mitigated Mn dissolution. This work provides conclusive evidence that modulating bulk electrolyte solvation is a potent and direct strategy for stabilizing LMR cathodes, establishing a vital design principle for next-generation battery systems.

25 ENERGY STORAGE↗

Geothermal district energy systems coupled with seasonal underground thermal energy storage: a U.S. techno-economic screening by climate and geology

In the United States, cooling-dominated commercial building loads can cause geothermal heat pump-based district energy systems to accumulate a long-term subsurface thermal imbalance, motivating the incorporation of seasonal underground thermal energy storage. We developed a transferable workflow to evaluate geothermal district systems that pair ground heat exchangers with seasonal underground thermal energy storage. Using standardized hourly loads for seven commercial buildings and a uniform cost framework, we simulated ten U.S. cities with a physics-based ground heat exchanger model, subsurface storage simulations, and economic assessment to isolate the roles of climate and hydrogeology. In cooling-dominated cities, underground thermal energy storage supplied the majority of annual cooling, cutting electricity use and summer peaks substantially while achieving levelized costs comparable to or below conventional chiller-boiler plants. In cooler climates, the storage share shrunk, required borefield size and costs rose, and levelized cost of energy increased nearly linearly with declining underground thermal energy storage fraction, indicating storage fraction as the primary economic lever. Sensitivity analysis showed capital risk dominated by borefield drilling and surface heating, ventilation, and air-conditioning and piping, with underground thermal energy storage costs secondary. This workflow provides a transparent foundation for site-specific design and screening of next-generation geothermal district energy systems.

25 ENERGY STORAGE↗