DOE OSTI · 3013423
Boron isotopic analysis in bulk silicate materials using the Neoma MS/MS MC-ICP-MS
Abstract
Boron (B) isotopes are a valuable tracer with applications ranging from geological, environmental, and nuclear studies because B isotopic fractionation is highly sensitive to chemical processes yielding distinct isotopic trends in natural and anthropogenic systems. Despite this wide applicability, there remain relatively few measurements on well-described reference materials and in some cases, poor agreement between various methods. We report a method for boron isotope ratio measurement in solution on the Neoma MS/MS MC-ICP-MS specifically targeting bulk silicates. We evaluate the performance of the method and instrument as it relates to the measurement of the absolute boron isotope ratio ( 10 B/ 11 B). The results indicate that the method produces data in agreement with literature values and that the sample–standard bracketing technique is appropriate for the Neoma MS/MS MC-ICP-MS which has been in use for decades on previous generation instruments. Careful tuning of the MS/MS lenses is required to obtain precision comparable to non MS/MS equipped MC-ICP-MS. With careful tuning, internal and external precisions of ∼0.3‰ were achieved. However, when the MS/MS is not properly tuned external precisions exceed 3‰. Nevertheless, our results for IAEA B-6, BCR-2, BHVO-2 and W-2a reference materials overlap the 1σ range of previously reported 10 B/ 11 B. Data are reported for total boron quantities down to a few tens of nanograms. Our procedure yielded blanks as low as 3 ng but up to 29 ng, making blank corrections important for small samples sizes in the few 10s of nanogram range. We report B isotope ratios for AGV-2G, SL-1G, GSC-2G, GSD-2G, GSE-2G, RLS-132, RLS-140, NKT-1G, and T1-G glass reference materials that have not been previously reported in the literature.
Keep this discovery
Explore connections, maps & timelines
Scott, Sean R. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)] (ORCID:0000000336974635), Coble, Matthew A. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)] (ORCID:0000000275360559), Sievers, Natalie E. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)], Hobbs, Kirby P. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)] (ORCID:0009000485372811), Schlieder, Tyler D. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)] (ORCID:0000000243826537), Zimmer, Mindy M. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)] (ORCID:0000000318661889). 2025-12-11. Boron isotopic analysis in bulk silicate materials using the Neoma MS/MS MC-ICP-MS. https://doi.org/10.1039/d5ja00267b
Cite the original work for its findings. Save a collection to share your selection of sources.