Obtaining bulk T requires measuring apparent sample interface T surface , knowledge of any window conditions T window , and knowledge of thermal transport from the sample to the window. To obtain bulk T with uncertainties below 5% requires relatively small uncertainties in each of these areas, and large uncertainties in one area require smaller uncertainties in others to maintain the error budget. For example, if T window is known to 10%, a 5% total uncertainty can be obtained if T surface is known to 1% and combined transport uncertainties are known to 20%. If T surface can only be measured to 2%, combined transport uncertainties must be 17% to reach the same overall uncertainty. As the form of transport is unknown at high pressure, and window temperatures are difficult to measure by their very nature, reducing surface T uncertainties is the practical first step. Here we will discuss various error sources in the measurement of apparent T surface , and which ones must be correctly obtained prior to the experiment.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Akin, Minta C., Ambrose, W. Pat. 2024-09-30. Executive summary of error sources in dynamic surface temperature measurements. https://doi.org/10.2172/3013739