Search NASA⌕ Search

DOE OSTI · 3017656

Novel Method for Domestic Stable Isotope Production

Abstract

This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species ( 35 Cl- and 37 Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

McDonald, Mark N. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)], Saavedra Lopez, Johnny [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)] (ORCID:0000000275425826), Humble, Paul H. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)], Salalila, Marsobyn [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)], Horkley, Lawrence Kenny [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)], McNeff, Patrick S. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)], Serkowski, Jason E. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)], Schlieder, Tyler [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)], Bottenus, Daniel R. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)] (ORCID:000000024230354X). 2026-01-16. Novel Method for Domestic Stable Isotope Production. https://doi.org/10.2172/3017656

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Novel Method for Domestic Stable Isotope Production (CRADA #667) Final Report

This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species (35Cl- and 37Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.

07 ISOTOPE AND RADIATION SOURCES↗