Search NASASearch

DOE OSTI · 3018390

Angular Correlation Date Measurements with the GeRMAC system

Abstract

Advanced modeling and simulation efforts have improved at Idaho National Laboratory in recent years with a solid foundation of experimental results. Current computational methods represent significant modeling capabilities but are limited by the accuracy and availability of nuclear data. The creation of pre- and post-processing software tools to address these limitations is fundamental to the improvement of nuclear science modeling capacities. One aspect of predictive modeling tools deals with gamma-rays emitted from radionuclides, including fissile or fissionable material, fission products, or activation products, produced in reactor experiments or other neutron environments. The resulting radionuclides decay in unique ways, providing complications upon measurement as a result of random and cascade, or true, coincidence summing. These effects are not easily quantified during modeling efforts of gamma-ray source terms., The germanium rotational measurements for angular correlation (GeRMAC) system was built to quantify the relative angles for gamma rays emitted by radionuclides of interest to investigate true coincidence, or cascade, summing as well as the nuclear energy levels of decay schemes of interest. Proof of concept studies utilize a series of laboratory check sources to provide validity, and it will soon be used to perform the same measurements for fission products of interest. The resulting data can be used to implement into a Monte Carlo code, such as Geant4, to provide more precise gamma-ray source terms following irradiations of materials.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Holschuh, Tommy [Idaho National Laboratory] (ORCID:0000000215214314), Quist, Teancum Earl [Idaho National Laboratory], Chichester, David L [Idaho National Laboratory] (ORCID:0000000285114458), Diaz, Jaime [Northern Arizona University]. 2025-05-23. Angular Correlation Date Measurements with the GeRMAC system. https://www.osti.gov/biblio/3018390

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Validation and Verification of Python based Neutron Spectrum Unfolding Software

To validate and verify the python-based code (PySL), designed to replicate the programs used by STAYSL for Beam Correction Factor (BCF) and Self-Shielding Factor (SHIELD), a series of tests were performed. To test BCF a python script was written to generate a random flux history file and both versions of the code processed the data. The test verified matching values up to at least one decimal place, approximately 10,000 tests where run and each one passed. Isotopes began to fail the tests once neutron saturation was reached. To verify this the total time of exposure was varied the isotopes that failed were compared to a list of their half-lives. The test process for SHIELD was very similar but, in this case, the code began by producing an input file with varying thickness and device type/environment for the SHIELD input. The failure condition for this test was if any of the data points for an isotope had a difference above 3%. Approximately 40 of these tests were run and there were only 3 isotopes that had reoccurring failures but only 2% of their points were above the 3% difference. A visual comparison was conducted by plotting the results from both programs. Although the test failed, the differences between their values were minuscule, and the self-shielding factor’s shape was preserved when plotted. Next steps for this project will be validating and verifying the python-based SigPhi code and then reproducing and testing the least squares unfolding performed by STAYSL.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS

Advanced Test Reactor Neutron Dosimetry Report - Cycle 175C: Results of Neutron Dosimetry Measurements for the Advanced Test Reactor Cycle 175C

Results of neutron dosimetry measurements in ATR for cycle 175C are presented. A single set of cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS

Radiological Dose Consequence Modeling Parameters for Reactor and Nonreactor Nuclear Facilities

To assure consistency between DOE and NRC safety basis requirements this ECAR documents the DOE basis requirements for dose consequence assessments in accordance with Standard DOE-STD-3009-2014. The methodology in this ECAR outlines parameters for evaluating airborne radiological releases and provides a consistent basis for assessing current and future DOE NE facilities.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS