Search NASA⌕ Search

DOE OSTI · 3018545

Fermilab PIP-II Master Oscillator and Precision Reference Line Design and Construction

Abstract

The phase averaging reference line system pro- vides the RF phase reference, LO and clock sig- nals to the LLRF and other accelerator sub- systems. The PIP-II linac has RF systems at three frequencies – 162.5 MHz, 325 MHz and 650 MHz. A temperature-stabilized, low-phase- noise oscillator is used as the master oscil- lator. Phase reference signals at 162.5 MHz, 325 MHz, and 650 MHz, along with LO signals at 182.5 MHz, 345 MHz, 670 MHz and LLRF clocks at 1320 MHz and 1300 MHz, are generated in temperature-controlled RF modules at each fre- quency section. A phase reference from each module travels to the next section, where it is doubled to produce required frequencies. The reference also travels alongside the accelerating cavities in the tunnel, allowing cavity probe and reference cables to temperature track and reduce measurement errors from temperature changes or phase drift.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Syed, Ahmed [Fermilab]. 2025-10-30. Fermilab PIP-II Master Oscillator and Precision Reference Line Design and Construction. https://doi.org/10.2172/3018545