Search NASASearch

DOE OSTI · 3019440

Using Simulation to Interpret LArS's Results

Abstract

Scintillation light analysis in liquid argon based neutrino detectors is restrained in capability due to uncertainty in fundamental constants critical to the analysis process. One such property is the Rayleigh scattering length of liquid argon. In the fall of 2023, the TallBo cryostat, located in the Noble Liquid Testing Facility (NLTF) at Fermilab, was used to study the scattering length of liquid argon in the Liquid Argon Scattering (LArS) experiment. Due to systematic errors unknown during measurement analysis, LArS s measurements were quite uncertain. By simulating the LArS experiment, we found that the downturn in detector count rate as a function of liquid argon height at low heights was caused by a misplaced silicon photo multiplier (SiPM). With concentrated effort, we may be able to successfully correct this effect by understanding the relationship between the specified Rayleigh scattering length and the measured attenuation length. With this information and further progression in analysis, we may be able to extract corrected measurements from the LArS data and attain a tangible experimental measurement of the scattering length of liquid argon.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Breaux, Auto D. [Tulane U.]. 2025-07-28. Using Simulation to Interpret LArS's Results. https://doi.org/10.2172/3019440

Cite the original work for its findings. Save a collection to share your selection of sources.