Search NASA⌕ Search

DOE OSTI · 3024238

2022 07 14 Acoustic Sensor Deployment at INL NSTR [Slides]

Abstract

These slides contain the coordinates, map and photographs of the deployment that occurred on July 14, 2022 at INL NSTR.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ocampo Giraldo, Luis A.. 2022-08-02. 2022 07 14 Acoustic Sensor Deployment at INL NSTR [Slides]. https://doi.org/10.2172/3024238

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Regression Analysis with the Directed Infusion of Data

Integrating artificial intelligence and machine learning tools into industry necessitates large-scale collaborative efforts that ensure the robust and accurate execution of downstream analytics such as time series prediction, uncertainty quantification, grid optimization, and condition monitoring. However, concerns related to data privacy pervade the nuclear industry due to the proprietary nature of its data and the possibility of data leakage. Legacy techniques such as encryption often require the explicit transmission of data to trustworthy parties, thereby inviting data leakage concerns. The ideal collaboration scenario avoids the explicit dissemination of data/code while maintaining experimental fidelity, which is currently accomplished using various techniques such as trusted execution environments, homomorphic encryption, differential privacy, and multimatrix masking. These techniques, however, often necessitate a trade-off between trust, efficiency, and utility. This article extends a previously proposed technique called the directed infusion of data (DIOD) that ensures data privacy, allows for scalable obfuscation, and combats the risk of data leakage without compromising utility. The experiments discussed in this article examine a regression-type scenario using DIOD with the goal of preserving the inferential link between two variables. Using the point-kinetics equations, regression experiments compare the performance of a model trained using the original data to that of a model trained using the obfuscated data, which produced identical results. Our claim is further strengthened by an information theoretic proof and experiment, which showed that the inferential content between variables remains the same after obfuscation, thereby avoiding the required communication of the proprietary data.

47 - OTHER INSTRUMENTATION↗

Mounted Accelerometer Frequency Response of Adhesive Products and Aluminum Frame Quick Mounts

An accelerometer mounting technique has large implications on the frequency range and accuracy of the measurement, with stiffness and the mass relative to the monitored structure as the primary concerns. The International Organization for Standardization (ISO) gives an extensive list in 5348:2021, detailing mounting methods, and provides recommendations for testing mounts that are not specifically defined. In the nuclear industry on the laboratory scale, there is a need for vibration measurements for predictive maintenance and process monitoring that are nondestructive and capable of working in high-temperature environments. Commercial adhesive products with easy application and removal were tested as nondestructive methods, while quick mounts to a commonly used aluminum frame were tested as nondestructive and have potential applicability in high-temperature environments. The sinusoidal excitation method was used, measuring frequencies from 50 Hz to 10 kHz in one-third octave band intervals, utilizing three accelerometers and comparing the results to those obtained with the stud-mounting method. Using the lowest ±3 dB threshold across each accelerometer, foam dots and poster strips were not successful, and foam tapes were accurate up to 2000 Hz, hose clamps and zip ties up to 800 Hz, and a custom 3D printed mount up to 1000 Hz. Knowing the limitations of each mounting technique allows for accurate measurements within the appropriate range.

47 - OTHER INSTRUMENTATION↗

Innovative PLC Design for Optimized Potable Water Managment

My project here at Idaho National Laboratory (INL) was to work on Potable Water PLC Design (Programmable Logic Controllers). I was tasked in making a new panel design for the PLC system that will be moved from TRA BLDG 696 to TRA BLDG 608. This design needed to be updated since the old PLC system being about 20 years old. The manufacturer of the MicroLogix 1200 life expectancy showed it to be 10-20 years, and the system was discontinued in 2017. The new system we implemented was called CompactLogix Controller 5380, along with a new 24 VDC/10 Amp Power Supply. I made a design using Microsoft Visio, with the new material. But we needed to add it onto an Aluminum Panel that the system will be mounted onto, we need Unistrut’s for the aluminum panel to be mounted to. Some of the material we will still be using, like the R1 Alarm Relay, will be moving with the PLC system. The rest of the material will be new supplies that need to be updated systems, which the site is waiting for to complete the PLC system.

47 - OTHER INSTRUMENTATION↗