DOE OSTI · 3362876
ACRRF High-Bay Dose Calculations using MCNP (Part B)
Abstract
ACRR radiation outputs through vertical cavities have been documented in two reports. In Part B, the maximum dose from the unshielded central cavity, FREC-II, and NRS is calculated to inform the safety basis. The maximum dose is ≈1430 mrem per 300 MJ, or ≈40,930 rem/hr for full-power operation. A verification study completes the V&V of the modeling. Supplementary studies of variance-reduction techniques, model sensitivities, and aircraft dose above the ACRRF are included.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Cardoni, Jeffrey N. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)] (ORCID:0009000466954496), Dodson, Zackary Glen [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)] (ORCID:0000000271704465), Phillips, Jesse [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)], Jankovsky, Zachary Kyle [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)]. 2026-05-01. ACRRF High-Bay Dose Calculations using MCNP (Part B). https://doi.org/10.2172/3362876
Cite the original work for its findings. Save a collection to share your selection of sources.