Search NASASearch

DOE OSTI · 3366491

Radiological Safety Analysis Computer (RSAC) Program Version 7.4 Users’ Manual

Abstract

The Radiological Safety Analysis Computer (RSAC) Program Version 7.4 (RSAC-7) is the newest version of the RSAC legacy code. RSAC-7 calculates the consequences of a release of radionuclides to the atmosphere. Users generates a fission product inventory from either reactor operating history or a nuclear criticality event. RSAC-7 models the effects of high-efficiency particulate air filters or other cleanup systems and calculates the decay and ingrowth during transport through processes, facilities, and the environment. Doses are calculated for inhalation, air immersion, ground surface, ingestion, and cloud gamma pathways. RSAC-7 is used as a tool to evaluate accident conditions in emergency response scenarios, radiological sabotage events, and safety basis accident consequences. This users’ manual contains the mathematical models and operating instructions for RSAC-7. Instructions, screens, and examples are provided to guide the user through the functions provided by RSAC-7. This program is designed for users who are familiar with radiological dose assessment methods.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Schrader, Bradley J. [Idaho National Laboratory (INL), Idaho Falls, ID (United States)]. 2025-09-29. Radiological Safety Analysis Computer (RSAC) Program Version 7.4 Users’ Manual. https://doi.org/10.2172/3366491

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Validation and Verification of Python based Neutron Spectrum Unfolding Software

To validate and verify the python-based code (PySL), designed to replicate the programs used by STAYSL for Beam Correction Factor (BCF) and Self-Shielding Factor (SHIELD), a series of tests were performed. To test BCF a python script was written to generate a random flux history file and both versions of the code processed the data. The test verified matching values up to at least one decimal place, approximately 10,000 tests where run and each one passed. Isotopes began to fail the tests once neutron saturation was reached. To verify this the total time of exposure was varied the isotopes that failed were compared to a list of their half-lives. The test process for SHIELD was very similar but, in this case, the code began by producing an input file with varying thickness and device type/environment for the SHIELD input. The failure condition for this test was if any of the data points for an isotope had a difference above 3%. Approximately 40 of these tests were run and there were only 3 isotopes that had reoccurring failures but only 2% of their points were above the 3% difference. A visual comparison was conducted by plotting the results from both programs. Although the test failed, the differences between their values were minuscule, and the self-shielding factor’s shape was preserved when plotted. Next steps for this project will be validating and verifying the python-based SigPhi code and then reproducing and testing the least squares unfolding performed by STAYSL.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS

Advanced Test Reactor Neutron Dosimetry Report - Cycle 175C: Results of Neutron Dosimetry Measurements for the Advanced Test Reactor Cycle 175C

Results of neutron dosimetry measurements in ATR for cycle 175C are presented. A single set of cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS

Radiological Dose Consequence Modeling Parameters for Reactor and Nonreactor Nuclear Facilities

To assure consistency between DOE and NRC safety basis requirements this ECAR documents the DOE basis requirements for dose consequence assessments in accordance with Standard DOE-STD-3009-2014. The methodology in this ECAR outlines parameters for evaluating airborne radiological releases and provides a consistent basis for assessing current and future DOE NE facilities.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS