DOE OSTI · 3387215
Enhanced Component Performance Study: Emergency Diesel Generators 1998-2024
Abstract
This report presents an enhanced performance evaluation of the emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2024 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2024. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in Nuclear Regulatory Commission (NRC) probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time-period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed include subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: • EPS and HPCS EDG frequency of start demands (demands per reactor year) • EPS and HPCS EDG frequency of FTLR demands • EPS and HPCS EDG frequency of run>1H hours. The following decreasing trends were identified for EDGs for the most recent 10-year period: • EPS EDG FTR>1H failure rate • EPS EDG unreliability • EPS and HPCS EDG frequency of FTR>1H events (failures per reactor year).
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Ma, Zhegang [Idaho National Laboratory (INL), Idaho Falls, ID (United States)] (ORCID:0000000229738557), Liu, Tao [Idaho National Laboratory (INL), Idaho Falls, ID (United States)], Johnson, Nancy [Idaho National Laboratory (INL), Idaho Falls, ID (United States)] (ORCID:0000000251371536), Merickel, John Wesley [Idaho National Laboratory (INL), Idaho Falls, ID (United States)] (ORCID:0009000732730568). 2025-07-01. Enhanced Component Performance Study: Emergency Diesel Generators 1998-2024. https://doi.org/10.2172/3387215
Cite the original work for its findings. Save a collection to share your selection of sources.