Search NASASearch

DOE OSTI · 3506068

Forensic characterization of surrogate nuclear explosion debris: radiochemical and spectroscopic strategies for method validation

Abstract

Surrogate nuclear explosion debris (SNED) has emerged as a critical platform for advancing post-detonation nuclear forensic analysis in the absence of readily accessible historic materials. SNED enables controlled investigation and validation of analytical methodologies used to interrogate the chemical, isotopic, radiological, and microstructural signatures preserved in nuclear explosion debris. This review presents an integrated assessment of destructive and non-destructive analytical techniques commonly employed within decision-driven nuclear forensic workflows. Each technique is discussed individually while highlighting how it contributes to different stages of post-detonation analysis. Core methods – including gamma and alpha spectrometry, ICP-MS, TIMS, SIMS, SEM-EDS, XRF, LIBS, vibrational spectroscopy, and X-ray absorption spectroscopy – are critically evaluated with respect to forensic maturity, information content, and matrix limitations. Emphasis is placed on the role of SNED in benchmarking multi-modal workflows and identifying gaps in reproducing heterogeneity, fractionation, and radiation-driven evolution relevant to forensic attribution.

Explore related subjects

Keep this discovery

BibTeXRIS

Burns, Austin [University of Central Florida, Orlando, FL (United States)] (ORCID:0009000380302382), Anagnostopoulos, Vasileios [University of Central Florida, Orlando, FL (United States)] (ORCID:0000000256356722). 2026-07-24. Forensic characterization of surrogate nuclear explosion debris: radiochemical and spectroscopic strategies for method validation. https://doi.org/10.1515/ract-2026-0017

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related discoveries

Experimental and analytical ion thruster research

The results of further spectroscopic studies on the plume from a 3 cm ion source operated on an argon propellant is reported on. In particular, it is shown that it should be possible to use the spectroscopic technique to measure the plasma density of the ion plume close to the grids, where it is difficult to use electrical probe measurements. How the technique, along with electrical probe measurements in the far downstream region of the plume, can be used to characterize the operation of a three-grid, 15 cm diameter thruster from NASA JPL is outlined. Pumping speed measurements on the Vacuum Research Facility have shown that this facility should be adequate for testing the JPL thruster at pressures in the low 10(exp -5) Torr range. Finally, we describe a simple analytical model which can be used to calculate the grid impingement current which results from charge-exchange collisions in the ion plume.

Wilhelmus M. Ruyten

X-ray linear dichroic tomography of crystallographic and topological defects

Abstract The functionality of materials is determined by their composition 1–4 and microstructure, that is, the distribution and orientation of crystalline grains, grain boundaries and the defects within them 5,6 . Until now, characterization techniques that map the distribution of grains, their orientation and the presence of defects have been limited to surface investigations, to spatial resolutions of a few hundred nanometres or to systems of thickness around 100 nm, thus requiring destructive sample preparation for measurements and preventing the study of system-representative volumes or the investigation of materials under operational conditions 7–15 . Here we present X-ray linear dichroic orientation tomography (XL-DOT), a quantitative, non-invasive technique that allows for an intragranular and intergranular characterization of extended polycrystalline and non-crystalline 16 materials in three dimensions. We present the detailed characterization of a polycrystalline sample of vanadium pentoxide (V 2 O 5 ), a key catalyst in the production of sulfuric acid 17 . We determine the nanoscale composition, microstructure and crystal orientation throughout the polycrystalline sample with 73 nm spatial resolution. We identify and characterize grains, as well as twist, tilt and twin grain boundaries. We further observe the creation and annihilation of topological defects promoted by the presence of volume crystallographic defects. The non-destructive and spectroscopic nature of our method opens the door to operando combined chemical and microstructural investigations 11,18 of functional materials, including energy, mechanical and quantum materials.

Science & Technology - Other Topics

230Th/234U radiochronometry for uranium materials by alpha spectrometry for nuclear forensics analysis

We have developed an alpha spectrometry method for 230Th/234U radiochronometry to determine the model separation age for uranium materials. This method offers an alternative to the more commonly used, but significantly more resource intensive multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) while providing similar accuracy and precision. The development included radiochemical separation of uranium and thorium, calibration of the 232U tracer and the alpha spectrometry measurement. The method was validated by analyzing a certified reference material, CRM 125-A, which is a uranium oxide pellet assay, isotopic, and radiochronometric standard. The results were compared to those obtained by our routine MC-ICP-MS 230Th/234U radiochronometry analysis method to assess the performance parameters for alpha spectrometry compared to the state-of-the-art technique.

Macsik, Zsuzsanna [Los Alamos National Laboratory