Search NASASearch

DOE OSTI · 3510113

Characterization of lateral amorphous selenium photodetectors for low-photon and VUV detection at cryogenic temperatures

Abstract

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies ≥80% and area under the curve (AUC) ≥ 0.85 using as few as ∼ 6800 incident 401 nm photons, corresponding to ∼ 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

Explore related subjects

Keep this discovery

BibTeXRIS

Rooks, Michael [University of Texas at Arlington, TX (United States); Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)] (ORCID:0000000216296825), Abbaszadeh, S. [University of California, Santa Cruz, CA (United States)], Asaadi, J. [University of Texas at Arlington, TX (United States)], Chirayath, V. A. [University of Texas at Arlington, TX (United States)], Febbraro, M. [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States); Air Force Institute of Technology, WPAFB, OH (United States)], García-Peris, M. Á. [University of Manchester (United Kingdom)], Gramellini, E. [University of Manchester (United Kingdom)], Hellier, K. [University of California, Santa Cruz, CA (United States)], Sudarsan, B. [Rutgers University, New Brunswick, NJ (United States)] (ORCID:0000000262285043), Tzoka, I. [University of Texas at Arlington, TX (United States)] (ORCID:0000000178115068). 2026-01-23. Characterization of lateral amorphous selenium photodetectors for low-photon and VUV detection at cryogenic temperatures. https://doi.org/10.1088/1748-0221/21/01/p01032

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related discoveries

Comparing Thermal Neutron Scintillators for Use With SiPM-Readout Detectors

Scintillator-based thermal neutron detectors for scientific scattering facilities offer an effective combination of large-area coverage and good spatial resolution. At Oak Ridge National Laboratory, silicon photomultiplier (SiPM)-readout Anger cameras using 6 Li glass scintillators have been developed, but the spatial resolution of these detectors is limited by the relatively low light yield of the glass. Recently, several brighter scintillator compositions with sufficient 6 Li concentration have emerged as promising candidates for higher-resolution imaging. Here, in this work, we evaluate five scintillator materials: GS20, LiF/ZnS:Ag, LiF/ZnO:Zn, LiI:Eu, and Cs 2 LiYCl 6 :Ce, each mounted on a SiPM Anger camera. For each scintillator, the neutron detection efficiency, spatial resolution, and count rate capabilities were measured and compared. Each of the new compositions achieved a spatial resolution better than 0.5 mm, compared to 0.66 mm for GS20, with LiI:Eu reaching the best value of 0.32 mm. Although these compositions improve the spatial resolution of the Anger camera, their longer pulse decay times limit their use in high count rate applications, and the camera’s hardware must be optimized for the different properties of the new scintillators.

Neutron detectors

Scintillator Library

This website provides measured scintillation properties of many inorganic and organic materials and citations to published papers in which the original measurements were reported. It is intended for two main uses: a web-accessible reference to useful scintillation detector materials and properties; an aid in developing fundamental theories or empirical relations between basic material properties and scintillation performance. To this end, both strong and weak scintillators have been included as well as those where sensitive measurements have not detected any scintillation emissions.

Shook, L. [University of California, Berkeley, CA