Search NASASearch

DOE OSTI · 3676759

Vasomotion in Human Fingers

Abstract

Introduction: We describe methods by which vasomotion can be recorded in awake and anesthetized human subjects without significant interference from other spontaneous vascular oscillations. Methods: In three separate studies, we used photoplethysmography (PPG) to record vasomotion in fingertips. In Study 1, we induced chemical sympathectomy in the studied hand of 11 awake subjects who received intravenous dexmedetomidine infusions. In Study 2, we administered four progressively increasing intravenous dexmedetomidine infusions to 16 awake volunteers. In Study 3, we recorded vasomotion simultaneously from 6 fingers of 7 patients who were under dexmedetomidine-based anesthesia. Five-minute epochs of PPG recordings that displayed slow vascular oscillations were analyzed for frequency and amplitude. Results: In Study 1, vasomotion frequencies were 0.025 ± 0.008 Hz. In Study 2, vasomotion frequencies were 0.033 ± 0.006 Hz, and 0.032 ± 0.008 Hz during the two highest dexmedetomidine infusion steps. In Study 3, vasomotion frequencies ranged from 0.020 to 0.037 Hz and were observed in all 6 fingers, with no synchrony between the six fingers. Conclusion: The vascular oscillations we observed without significant interference from other spontaneous oscillations are independent of neural activity (Study 1), local in nature (Study 3), and associated with alpha-2-adrenoceptor activation, consistent with known properties of vasomotion.

Explore related subjects

Keep this discovery

BibTeXRIS

Talke, Pekka (ORCID:0000000348392376), Maltz, Jonathan, Talke, Marcus, Scheinin, Mika (ORCID:0000000175799126), Diab, Mohamed. 2025-08-26. Vasomotion in Human Fingers. https://doi.org/10.1159/000548155

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related discoveries

The Physiological Basis for Spacecraft Environmental Limits

This document is intended to provide a description of the physiological effects that determine the environmental limits required in spacecraft. The existing limits for operational environments are described in terms of acceptable physiological changes. Tolerance limits are discussed for exposures to environmental factors during unusual or contingency situations. Where environmental limits may be required but do not presently exist or where additional research is required to refine existing limits, these research needs are specified.

J M Waligora

Medical Aspects of Gemini Extravehicular Activities

The medical aspects of Gemini extravehicular activities are principally concerned with the physiological responses to high workloads, high thermal stresses, and low fatigue tolerance. Analysis of physiological instrumentation data. from extravehicular flights and training operations contributed significantly to the understanding of extra-vehicular workloads and the means of controlling these workloads.

G Fred Kelly

Electric spiking activity in epithelial cells

Epithelial cells (human keratinocyte cells and the canine MDCK cell line), traditionally viewed as electrically non-self-excitable and involved primarily in physiological functions such as barrier presentation, absorption, secretion, and protection, are shown here to exhibit traveling extracellular electric charge when they recover from spatially focused, laser-induced wounding of confluent monolayers cultured on a multielectrode array chip. Voltage spikes measured on these electrodes display depolarization, repolarization, and hyperpolarization phases with amplitudes similar to the action potentials of neurons but with the markedly slower duration of 1 to 2 s. Some propagate distances up to hundreds of μm from the wound with a mean speed of around 10 mm s −1 . Generation and transmission of bioelectric signals are significantly influenced by the perturbation of mechanosensitive cationic ion channels. These direct measurements confirm bioelectric signaling that previous work has hypothesized to regulate epithelial cell development and may have relevance to the frequency parameter selection of bioelectric devices.

Science & Technology - Other Topics