Search NASA⌕ Search

DOE OSTI · 920432

MAPMT H7546B anode current response study for ILC SiD muon system prototype

Abstract

The proposed Silicon Detector (SiD) concept for the ILC has barrel and end cap muon systems. An SiD scintillator based muon system prototype has 256 strips and was constructed from extruded strips, WLS fibers, clear fibers, and multianode photo multiplier tubes (MAPMT) Hamamatsu H7546B. Six MAPMTs were used. As a first step to understand strip output, the response of every anode to a given brightness of light and applied voltage must be measured. For the test, a custom made light source was used. Each MAPMT output was measured independently. The anode currents were measured at constant (green) input light brightness and the same photocathode to anode voltage (800V). The anode currents have a wide spread; for all tubes the maximum value is 5.23 times larger than the minimum value. The MAPMT cross talk was measured for one of the central inputs. The maximum cross talk value is about 4.9%. The average cross talk for the nearest four neighboring channels is 3.9%, for the farthest four is 1%. To assure the reproducibility and repeatability of the measurements, the double reference method was used.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dyshkant, A, Blazey, G, Francis, K, Hedin, D, Zutshi, V, Fisk, H, Milstene, C, Abrams, R. 2007-10-01. MAPMT H7546B anode current response study for ILC SiD muon system prototype. https://doi.org/10.1109/nssmic.2007.4437260. https://searchnasa.com/record/osti%3A920432/mapmt-h7546b-anode-current-response-study-for-ilc-sid-muon-system-prototype

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search NASA by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related reports

Design and Integration of High Precision Superconducting Magnet Power Supply Systems

This paper reviews the design and integration approach being taken to power more than 400 superconducting magnets in Electron Ion Collider (EIC) by power supplies ranging from 20V to 400V and 100A to 18kA. A major challenge is to integrate existing legacy power supplies with new high current systems and maximize performance and reduce costs. Successful implementation requires coordinated integration of power convertors, current regulation, quench protection, energy extraction, machine protection, controls and existing accelerator infrastructure.

43 PARTICLE ACCELERATORS↗

Searching for the Most Harmful Field Errors in the HSR IR Superconducting Magnets

In this project, we improve beam stability for the Electron-Ion Collider. Magnetic field errors can reduce beam stability, making it essential to identify the field errors that have the greatest impact on accelerator performance. However, this is particularly challenging because beam stability depends on the complex interactions of many magnetic field errors, resulting in a high-dimensional and nonlinear optimization problem. We determine which field errors are the most influential for the large physical aperture superconducting magnet B2PF, a critical magnet in the Interaction Region (IR) in the Hadron Storage Ring (HSR). We complete and analyze nearly 30,000 simulations on the Brookhaven National Laboratory Linux Cluster by varying 18 nonlinear magnetic field errors. We evaluate beam stability using the dynamic aperture and the tune diffusion. We identify the field errors that most strongly influence beam stability and establish quantitative field error tolerances that improve accelerator performance.

43 PARTICLE ACCELERATORS↗