Search NASA⌕ Search

SEARCH · Search NASA

Results for “100%”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Zooming in: SCREAM at 100 m using regional refinement over the San Francisco Bay Area

Pushing global climate models to large-eddy simulation (LES) scales over complex terrain has remained a major challenge. This study presents the first known implementation of a global model – SCREAM (Simple Cloud-Resolving E3SM Atmosphere Model) – at 100 m horizontal resolution using a regionally refined mesh (RRM) over the San Francisco Bay Area. Two hindcast simulations were conducted to test performance under both strong synoptic forcing and weak, boundary-layer-driven conditions. We demonstrate that SCREAM can stably run at LES scales while realistically capturing topography, surface heterogeneity, and coastal processes. The 100 m SCREAM-RRM substantially improves near-surface wind speed, temperature, humidity, and pressure biases compared to the baseline 3.25 km simulation, and better reproduces fine-scale wind oscillations and boundary-layer structures. These advances leverage SCREAM's scale-aware SHOC turbulence parameterization, which transitions smoothly across scales without tuning. Performance tests show that while CPU-only simulations remain costly, GPU acceleration with SCREAMv1 on NERSC's Perlmutter system enables two-day hindcasts to complete in under two wall-clock days. Our results open the door to LES-scale studies of orographic flows, boundary-layer turbulence, and coastal clouds within a fully comprehensive global modeling framework.

Geosciences↗

PV Inverter Experimental Dataset Version 2 with 100 Percent Power

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. The PV inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

14 SOLAR ENERGY↗

Study of Inverter Control Strategies on the Stability of Microgrids Toward 100% Renewable Penetration: Preprint

This paper investigates microgrid transient stability with mixed generation - synchronous generator (SG), grid-forming (GFM) and grid-following (GFL) inverters - under increasing penetration levels toward a 100% renewable generation microgrid. Specifically, the dynamics of a microgrid with an SG and GFL inverter(s), an SG with GFM inverter(s), and an SG with GFM and GFL inverters under each penetration are evaluated with an electromagnetic transient study with two critical dynamic events: unplanned islanding and switching in a pumped induction motor load. Analysis and simulation results indicate that the microgrid with GFL inverters running in parallel with the SG can provide a faster power response than the GFM inverters to compensate for the deviations of the frequency and voltage. The scenario with the mixed SG, GFM, and GFL inverter has the best transient and steady-state stability toward 100% inverter-based resource (IBR) penetration. This comprehensive study provides helpful references for microgrid engineers to understand the microgrid stability when facing various choice of installing IBRs (GFL, GFM, or mixed).

droop control↗

Study of Inverter Control Strategies on the Stability of Microgrids Toward 100% Renewable Penetration

This paper investigates microgrid transient stability with mixed generation - synchronous generator (SG), grid-forming (GFM) and grid-following (GFL) inverters - under increasing penetration levels toward a 100% renewable generation microgrid. Specifically, the dynamics of a microgrid with an SG and GFL inverter(s), an SG with GFM inverter(s), and an SG with GFM and GFL inverters under each penetration are evaluated with an electromagnetic transient study with two critical dynamic events: unplanned islanding and switching in a pumped induction motor load. Analysis and simulation results indicate that the microgrid with GFL inverters running in parallel with the SG can provide a faster power response than the GFM inverters to compensate for the deviations of the frequency and voltage. The scenario with the mixed SG, GFM, and GFL inverter has the best transient and steady-state stability toward 100% inverter-based resource (IBR) penetration. This comprehensive study provides helpful references for microgrid engineers to understand the microgrid stability when facing various choice of installing IBRs (GFL, GFM, or mixed).

droop control↗

A Cryogenic Readout IC with 100 KSPS in-Pixel ADC for Skipper CCD-in-CMOS Sensors

The Skipper CCD-in-CMOS Parallel Read-Out Circuit (SPROCKET) is a mixed-signal front-end design for the readout of Skipper CCD-in-CMOS image sensors. SPROCKET is fabricated in a 65 nm CMOS process and each pixel occupies a 50$\mu$m $\times$ 50$\mu$m footprint. SPROCKET is intended to be heterogeneously integrated with a Skipper-in-CMOS sensor array, such that one readout pixel is connected to a multiplexed array of nine Skipper-in-CMOS pixels to enable massively parallel readout. The front-end includes a variable gain preamplifier, a correlated double sampling circuit, and a 10-bit serial successive approximation register (SAR) ADC. The circuit achieves a sample rate of 100 ksps with 0.48 $\mathrm{e^-_{rms}}$ equivalent noise at the input to the ADC. SPROCKET achieves a maximum dynamic range of 9,000 $e^-$ at the lowest gain setting (or 900 $e^-$ at the lowest noise setting). The circuit operates at 100 Kelvin with a power consumption of 40 $\mu W$ per pixel. A SPROCKET test chip was submitted in September 2022, and test results will be presented at the conference.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First measurement of the nuclear-recoil ionization yield in silicon at 100 eV

We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4 keV down to 100 eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100 eV. These results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100)

Puerto Rico has committed to meeting its electricity needs with 100% renewable energy by 2050, along with realizing interim goals of 40% by 2025, 60% by 2040, the phaseout of coal-fired generation by 2028, and a 30% improvement in energy efficiency by 2040 as established in Puerto Rico Energy Public Policy Act (Act 17). To meet these goals and support widespread end-use electrification, Puerto Rico is exploring renewable energy and innovative technologies for energy storage, distributed generation, distribution control, electric vehicles, and energy efficient and responsive loads that can be deployed in each of Puerto Rico's cities and communities. Launched in February 2022, a two-year study entitled Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy (PR100) will perform a comprehensive analysis of stakeholder-driven pathways to Puerto Rico's clean energy future. This fact sheet describes the five activities this robust and objective energy analysis entails.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Hierarchical Data-Driven Protection for Microgrid with 100% Renewable Penetration: Preprint

The accurate detection and isolation of faults is critical for the reliable operation of microgrids (MGs). Traditional protection approaches are even more challenged for 100% renewable MGs because inverter-based resources (IBRs) are the only sources for fault current which are usually low and unpredictable/non-uniform. This calls for new protection scheme that can identify IBR fault responses and detect faults in MGs. Data-driven based protection can learn the pattern of IBR fault responses and make the correct decision to identify faults. Therefore, this paper presents a data-driven approach for fault localization in island MGs. The approach builds a training dataset of comprehensive fault scenarios that can be used to learn fault characteristics from processed measurements. The localization task is modeled as a binary classification problem at each relay, which simplifies the learning process. Then, a hierarchical decision mechanism is used to identify the fault location. The proposed approach is assessed using an exemplary MG with several grid-forming (GFM) and grid-following (GFL) inverters, where accurate estimation of fault location is achieved. The data-driven based protection approach developed in this paper provides a generic framework and useful guidance for power system protection engineers to achieve reliable protection for MGs with 100% renewables.

artificial intelligence↗

"Designing, simulating, and performing the 100-AV field test for the CIRCLES consortium: Methodology and Implementation of the Largest mobile traffic control experiment to date"

Previous controlled experiments on single-lane ring roads have shown that a single partially autonomous vehicle (AV) can effectively mitigate traffic waves. This naturally prompts the question of how these findings can be generalized to field operational, high-density traffic conditions. To address this question, the Congestion Impacts Reduction via CAV-in-the-loop Lagrangian Energy Smoothing (CIRCLES) Consortium conducted MegaVanderTest (MVT), a live traffic control experiment involving 100 vehicles near Nashville, TN, USA. This article is a tutorial for developing analytical and simulation-based tools essential for designing and executing a live traffic control experiment like the MVT. It presents an overview of the proposed roadmap and various procedures used in designing, monitoring, and conducting the MVT, which is the largest mobile traffic control experiment at the time. The design process is aimed at evaluating the impact of the CIRCLES AVs on surrounding traffic. The article discusses the agent-based traffic simulation framework created for this evaluation. A novel methodological framework is introduced to calibrate this microsimulation, aiming to accurately capture traffic dynamics and assess the impact of adding 100 vehicles to existing traffic. The calibration model's effectiveness is verified using data from a six-mile section of Nashville's I-24 highway. The results indicate that the proposed model establishes an effective feedback loop between the optimizer and the simulator, thereby calibrating flow and speed with different spatiotemporal characteristics to minimize the error between simulated and real-world data. Finally, We simulate AVs in multiple scenarios to assess their effect on traffic congestion. This evaluation validates the AV routes, thereby contributing to the execution of a safe and successful live traffic control experiment via AVs.

Ameli, Mostafa↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids: Preprint

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

Effect of surface segregation on the oxidation resistance of Cu 3 Pt ( 100 )

Alloying element segregation often occurs under a reactive environment but its interplay with the subsequent surface oxidation of the alloy remains unclear. Using synchrotron-based ambient-pressure x-ray photoelectron spectroscopy, we dynamically monitor the surface segregation in Cu 3 Pt(100) in response to temperature and oxygen gas. Vacuum annealing leads to surface segregation of Cu along with the enrichment of Pt in the subsurface region. Upon switching to the O 2 atmosphere, dissociative chemisorption of oxygen does not change the surface segregation profile from that under the vacuum annealing condition. A stepwise increase in the oxygen pressure results in the transformation pathway of Cu → Cu 2 O → CuO, in which the selective oxidation of Cu gives rise to further accumulation of Pt underneath the oxide/alloy interface that hinders the supply of Cu from the bulk to the oxide/alloy interface, thereby leading to the termination of the surface oxidation after the Cu 2 O → CuO conversion is completed. This differs from the transformation pathway of Cu → Cu 2 O → Cu 2 O/CuO for the oxidation of pure Cu and Cu-Au alloys, in which the oxidation of Cu continues and the Cu 2 O/CuO bilayer growth is constantly maintained. Furthermore, these key differences provide useful insight into alloy design for controlling the surface properties such as corrosion resistance and catalytic performance of Cu base alloys.

36 MATERIALS SCIENCE↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Examining Supply-Side Options to Achieve 100% Clean Electricity by 2035

The growing climate emergency requires a dramatic and rapid reduction of greenhouse gas emissions in the United States and internationally. This study evaluates a variety of 100% clean electricity system scenarios in 2035 that could put the United States on a path to economy-wide net-zero emissions by 2050, specifically focusing on technical requirements, challenges, and cost implications. The results highlight there are multiple approaches to cost-effectively achieve a net-zero carbon grid in 2035.

100% clean electricity↗

Equitable Clean Energy Transitions for Small Communities: NREL Supports Kingston, New York, in Building a Community-First Approach to 100% Renewable Energy

In 2017, the city of Kingston, New York,committed to meet 100% power consumption with renewableenergy sources by 2050. Leading by example, Kingston hadalready made significant strides in energy efficiency in citybuildings; however, meeting the new, ambitious goal meantthat maintaining energy and housing affordability would be achallenge. The poorest residents of the city face a significantenergy burden, spending up to a quarter of income on powerand heating bills.

100% renewable goals↗

Transient Stability Study of a Real-World Microgrid with 100% Renewables: Preprint

This paper performs a transient stability study of a real-world microgrid with 100% renewables to fully understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, the full-scale electromagnetic transient modeling of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid, which gives good references for the field deployment in terms of inverter configuration and coordination as well as the capabilities of black start and unplanned islanding.

100% renewable microgrid↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids: Preprint

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

A Sodium–Antimony–Telluride Intermetallic Allows Sodium-Metal Cycling at 100% Depth of Discharge and as an Anode-Free Metal Battery

In this work, repeated cold rolling and folding is employed to fabricate a metallurgical composite of sodium–antimony–telluride Na 2 (Sb 2/6 Te 3/6 Vac 1/6 ) dispersed in electrochemically active sodium metal, termed “NST-Na.” This new intermetallic has a vacancy-rich thermodynamically stable face-centered-cubic structure and enables state-of-the-art electrochemical performance in widely employed carbonate and ether electrolytes. NST-Na achieves 100% depth-of-discharge (DOD) in 1 m NaPF 6 in G2, with 15 mAh cm –2 at 1 mA cm –2 and Coulombic efficiency (CE) of 99.4%, for 1000 h of plating/stripping. Sodium-metal batteries (SMBs) with NST-Na and Na 3 V 2 (PO 4 ) 3 (NVP) or sulfur cathodes give significantly improved energy, cycling, and CE (>99%). An anode-free battery with NST collector and NVP obtains 0.23% capacity decay per cycle. Imaging and tomography using conventional and cryogenic microscopy (Cryo-EM) indicate that the sodium metal fills the open space inside the self-supporting sodiophilic NST skeleton, resulting in dense (pore-free and solid electrolyte interphase (SEI)-free) metal deposits with flat surfaces. The baseline Na deposit consists of filament-like dendrites and “dead metal”, intermixed with pores and SEI. Density functional theory calculations show that the uniqueness of NST lies in the thermodynamic stability of the Na atoms (rather than clusters) on its surface that leads to planar wetting, and in its own stability that prevents decomposition during cycling.

36 MATERIALS SCIENCE↗