Search NASA⌕ Search

SEARCH · Search NASA

Results for “2 column instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A Tracking Sun Photometer Without Moving Parts

This innovation is small, lightweight, and consumes very little electricity as it measures the solar energy attenuated by gases and aerosol particles in the atmosphere. A Sun photometer is commonly used on the Earth's surface, as well as on aircraft, to determine the solar energy attenuated by aerosol particles in the atmosphere and their distribution of sizes. This information is used to determine the spatial and temporal distribution of gases and aerosols in the atmosphere, as well as their distribution sizes. The design for this Sun photometer uses a combination of unique optics and a charge coupled device (CCD) array to eliminate moving parts and make the instrument more reliable. It could be selfcalibrating throughout the year. Data products would be down-welling flux, the direct-diffuse flux ratio, column abundance of gas phase constituents, aerosol optical depth at multiple-wavelengths, phase functions, cloud statistics, and an estimate of the representative size of atmospheric particles. These measurements can be used to obtain an estimate of aerosol size distribution, refractive index, and particle shape. Incident light is received at a light-reflecting (inner) surface, which is a truncated paraboloid. Light arriving from a hemispheric field of view (solid angle 2 steradians) enters the reflecting optic at an entrance aperture at, or adjacent to, the focus of the paraboloid, and is captured by the optic. Most of this light is reflected from an inner surface. The light proceeds substantially parallel to the paraboloid axis, and is detected by an array detector located near an exit aperture. Each of the entrance and exit apertures is formed by the intersection of the paraboloid with a plane substantially perpendicular to the paraboloid axis. Incident (non-reflected) light from a source of limited extent (the Sun) illuminates a limited area on the detector array. Both direct and diffuse illumination may be reflected, or not reflected, before being received on the detector array. As the Sun traverses a path in the sky over some time interval, the track of the Sun can be traced on the detector array. A suitably modified Sun photometer might be used to study the dynamics of an environment on another planet or satellite with an atmosphere.

Strawa, Anthony W.↗

Balloon-Borne Measurements of Total Reactive Nitrogen, Nitric Acid, and Aerosol in the Cold Arctic Stratosphere

Total reactive nitrogen (NO(Y)) between 15 and 29 km was measured for the first time on board a balloon within the Arctic cold vortex. Observations of HNO3, aerosol, and ozone were made by instruments on the same balloon gondola which was launched from Esrange, Sweden (68 deg N, 20 deg E) on January 23, 1989. The NO(y) mixing ratio was observed to increase very rapidly from 6 ppbv at 18 km altitude to a maximum of 21 ppbv at 21 km, forming a sharp layer with a thickness of about 2 km. A minimum in the NO(y) mixing ratio of 5 ppbv was found at 27 km. The measured HNO3 profile shows broad similarities to that of NO(y). This observation, together with the observed very low column amount of NO2, shows that NO(x) had been almost totally converted to HNO3, and that NO(y) was composed mainly of HNO3. The enhanced aerosol concentration between 19 and 22 km suggests that the maximum abundance of HNO3 trapped in the form of nitric acid trihydrate (NAT) was about 6 ppbv at 21 km. The sampled air parcels were highly supersaturated with respect to NAT. Although extensive denitrification throughout the stratosphere did not prevail, an indication of denitrification was found at altitudes of 27 and 22 km, and between 18 and 15 km.

Kondo, Y.↗

An Examination of the Recent Stability of Ozonesonde Global Network Data

The recent Assessment of Standard Operating Procedures for OzoneSondes (ASOPOS 2.0; WMO/GAW Report #268) addressed questions of homogeneity and long-term stability in global electrochemical concentration cell (ECC) ozone sounding network time series. Among its recommendations was adoption of a standard for evaluating data quality in ozonesonde time series. Total column ozone (TCO) derived from the sondes compared to TCO from Aura’s Ozone Monitoring Instrument (OMI) is a primary quality indicator. Comparisons of sonde ozone with Aura’s Microwave Limb Sounder (MLS) are used to assess the stability of stratospheric ozone. This paper provides a comprehensive examination of global ozonesonde network data stability and accuracy since 2004 in light of the sudden post-2013 TCO “dropoff” of ~3-4% that was reported previously at select stations (Stauffer et al., 2020). Comparisons with Aura OMI TCO averaged across the network of 60 stations are stable within about ±2% over the past 18 years. Sonde TCO has similar stability compared to three other TCO satellite instruments, and the stratospheric ozone measurements average to within ±5% of MLS from 50 to 10 hPa. Thus, sonde data are reliable for trends, but with a caveat applied for a subset of dropoff stations in the tropics and subtropics. The dropoff is associated with only one of two major ECC instrument types. A detailed examination of ECC serial numbers pinpoints the timing of the dropoff. However, we find that overall, ozonesonde data are stable and accurate compared to independent measurements over the past two decades.

Ryan M. Stauffer↗

Using Satellite Measurements of N2O to Remove Dynamical Variability from HCl Measurements

Column HCl measurements show deviations from the expected slow decline following the regulation of chlorine-containing compounds by the Montreal Protocol. We use the simultaneous measurements of N2O and HCl by the Microwave Limb Sounder (MLS) instrument on the Aura satellite to examine this problem. We find that the use of N2O measurements at a specific altitude to represent the impact of dynamical variability on HCl results in a derived linear trend in HCl that is negative (ranging from -2.5 to 5.3%decade-1) at all altitudes between 68 and 10 hPa. These trends are at or near 2 sigma statistical significance at all pressure levels between 68 and 10 hPa. This shows that analysis of simultaneous measurements of several constituents is a useful approach to identify small trends from data records that are strongly influenced by dynamical interannual variability.

Stolarski, Richard↗

Comparison of SBUV and SAGE II ozone profiles: Implications for ozone trends

Solar backscattered ultraviolet (SBUV) ozone profiles have been compared with Stratospheric Aerosol and Gas Experiment (SAGE) II profiles over the period October 1984 through June 1990, when data are available from both instruments. SBUV measurements were selected to closely match the SAGE II latitude/longitude measurement pattern. There are significant differences between the SAGE II sunrise and the sunset zonal mean ozone profiles in the equatorial zone, particularly in the upper stratosphere, that may be connected with extreme SAGE II solar azimuth angles for tropical sunrise measurements. Calculation of the average sunset bias between SBUV and SAGE II ozone profiles shows that allowing for diurnal variation in Umkehr layer 10, SBUV and SAGE II agree to within +/- 5% for the entire stratosphere in the northern midlatitude zone. The worst agreement is seen at southern midlatitudes near the ozone peak (disagreements of +/- 10%), apparently the result of the SBUV ozone profile peaking at a lower altitude than SAGE. The integrated ozone columns (cumulative above 15 km) agree very well, to within +/- 2.3% in all zones for both sunset and sunrise measurements. A comparison of the time dependence of SBUV and SAGE II shows that there was less than +/- 5% relative drift over the 5.5 years for all altitudes except below 25 km, where the SBUV vertical resolution is poor. The best agreement with SAGE is seen in the integrated column ozone (cumulative above 15 km), where SAGE II has a 1% negative trend relative to SBUV over the comparison period. There is a persistent disagreement of the two instruments in Umkehr layers 9 and 10 of +/- 4% over the 5.5-year comparison period. In the equatorial zone this disagreement may be caused in part by a large positive trend (0.8 K per year) in the National Meteorologica Center temperatures used to convert the SAGE II measurement of ozone density versus altitude to a pressure scale for comparison with SBUV. In the middle stratosphere (30-40 km), SBUV shows a 2-4% negative drift relative to SAGE II. If the actual ozone trends are considered, SBUV and SAGE II agree in showing little ozone change (less than 2%) between 1984 and 1990, except in layer 3 where SAGE II measures a large ozone decrease. But over 11 years, SBUV measured a 7% per decade ozone decrease between 40 and 50 km, decreasing in magnitude at lower altitudes, in good agreement with 11-year trends derived from the average of 5 Umkehr stations.

Mcpeters, R. D.↗

ADEOS Total Ozone Mapping Spectrometer (TOMS) Data Products User's Guide

Two data products from the Total Ozone Mapping Spectrometer (ADEOS/TOMS) have been archived at the Distributed Active Archive Center, in the form of Hierarchical Data Format files. The ADEOS/ TOMS began taking measurements on September 11, 1996, and ended on June 29, 1997. The instrument measured backscattered Earth radiance and incoming solar irradiance; their ratio was used in ozone retrievals. Changes in the reflectivity of the solar diffuser used for the irradiance measurement were monitored using a carousel of three diffusers, each exposed to the degrading effects of solar irradiation at different rates. The algorithm to retrieve total column ozone compares measured Earth radiances at sets of three wavelengths with radiances calculated for different total ozone values, solar zenith angles, and optical paths. The initial error in the absolute scale for TOMS total ozone is 3 percent, the one standard deviation random error is 2 percent, and the drift is less than 0.5 percent over the 9-month data record. The Level 2 product contains the measured radiances, the derived total ozone amount, and reflectivity information for each scan position. The Level 3 product contains daily total ozone and reflectivity in a 1-degree latitude by 1.25 degrees longitude grid. The Level 3 files containing estimates of UVB at the Earth surface and tropospheric aerosol information will also be available. Detailed descriptions of both HDF data files and the CDROM product are provided.

Krueger, A.↗

Enhancing Long-Term Trend Simulation of OH Through the Synergy of Model Simulations and Aura Ozone Monitoring Instrument (OMI) NO 2 and HCHO Retrievals

During the last few years, tremendous progress has been made to develop an efficient parameterization module using agile machine learning techniques. The aim of this module is to provide dynamic response of the tropospheric hydroxyl radical (OH) to its major drivers, including trace gases, aerosols, clouds, and meteorology. This module, named ECCOH (pronounced “echo”) and implemented in NASA’s GEOS-5 global model, offers an unrealized opportunity to unravel the convoluted response of OH to its underlying drivers while approaching the accuracy of full-chemistry without incurring excessive computational costs, making it suitable for climate models. However, the accurate representation of OH in ECCOH poses challenges due to the lack of representation of some of its critical inputs such as the abundance of NO 2 and HCHO concentrations. As such, we leverage the well-characterized satellite observations of NO2 and HCHO columns from Aura OMI to enhance their representation in ECCOH using an optimal interpolation method for the time period of 2005 - present. We show how the inclusion of OMI information can affect the spatiotemporal variability and long-term trends of OH, CO, and CH 4 across the globe. Additionally, we underscore the necessity of obtaining high-fidelity information regarding tropospheric ozone from the southern hemisphere from space, a region currently lacking full verification in models, posing a challenge to get a reasonable amount of chemical sink for CH 4 .

OH↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sea Salt and Dust Optical Depths in the Caribbean and Equatorial Western Atlantic: A Multi-technique Analysis

Many instruments and algorithms can estimate aerosol optical depth (AOD) of the atmosphere. The Moderate Resolution Imaging Spectroradiometer (MODIS) onboard the Aqua spacecraft provides estimates at several wavelengths. The Synergized Optical Depth of Aerosols (SODA) algorithm utilizes the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) onboard the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) spacecraft and the Cloud Profiling Radar (CPR) onboard the CloudSat spacecraft’s ocean returns to estimate AOD. CALIOP routinely estimates AOD for all individual layers detected within a column and these can be summed to generate a total column approximation. With the release of the Version 4.51 Lidar Level 2 data products in October 2023, direct estimates of total column optical depth are now derived using the Ocean Derived Column Optical Depths (ODCOD) algorithm. In this poster we investigate the multispectral AOD estimates, and derived Angstrom exponents of marine sea salt and dust provided by MODIS, SODA, CALIOP, and ODCOD in a major dust transport and deposition region of the equatorial Atlantic Ocean.

optical depth↗

GC/MS Method Development for Separating Lunar Volatile Ice Simulant Headspace Gases

Various investigators propose the lunar surface contains widely distributed volatiles, especially water- like species, i.e. OH and H2O. Surface volatiles are theorized to exist as a hydrated regolith layer, concentrated in extremely cold polar permanently shadowed regions (PSR), and/or solar wind implantation reservoirs in lunar glasses. The proposed sources of lunar surface volatiles range from cometary impacts, solar wind, or a supply present during moon formation. Future Artemis missions aim to collect and return the samples containing volatiles collected near lunar polar craters or PSRs. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving returned sample integrity as much as possible. Pristine volatile-bearing samples are invaluable to the scientific community seeking to unravel the history of the solar system. Realistically, a sample will experience alteration during collection, transportation back to earth, and storage. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on high-fidelity volatile-containing regolith simulants, the foundation for the future of cold curation. This abstract outlines the separation, identification, and quantification of headspace gases over volatile ice feed stock material using gas chromatography/mass spectrometry (GC/MS). Preliminary objectives concentrated on sample handling, reproducibility, and understanding the elution characteristics for each analyte. Initial GC/MS method development experiments utilized diluted static headspace sample preparation. Diluted samples were used because sampling headspace gases directly from a vial containing liquid analyte resulted in overloading of the column and detector. Overloading is evident based on chromatogram peak shapes and instrument contamination, or carry over, between experiments. A mixture of three alcohols were used for a majority of the sample handling and reproducibility studies. Reproducibility was tested via multiple users, calibration curves, and check standards. Stock solutions of condensed lunar volatile analytes included methanol, ammonia in methanol, hydrogen sulfide in water, and an equal volume mixture of methanol, ethanol, and isopropanol. Current samples use room air as the headspace sample matrix, however future experiments will incorporate an inert purge gas, such as argon or nitrogen. Three mL of each analyte solution were capped in separate 20 mL crimp top GC vials. Dilutions were carried out by removing an aliquot of headspace gases with a calibrated 1 mL gastight syringe and immediately transferring to a 20 mL capped crimp top vial. The GC/MS is a Thermo Fisher Trace 1310/ISQ 7000 with a TriPlus RSH autosampler and split/splitless injector module. The experiments outlined in this abstract use the following hardware: a 2.5 mL gastight headspace syringe tool, 1 mm ID x 78.5 mm length ultra-inert straight injection liner, and a TG-BondQ 30 m × 0.32 mm × 10 μm column. Various parameters, such as hardware selection and the temperature, pressure, and split ratio set points, continue to evolve as the overall experiment is refined. Diluted headspace chromatograms were collected for the individual stock solutions. Retention times, peak shapes, and mass spectra were evaluated and added to the data processing method for each molecule of interest. Figure 1 shows the total ion chromatograms for the three major lunar volatile simulant stock solutions: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. Tailing peak shapes for ammonia (2.98 min rt) and water (4.06 min rt) indicate the molecules are not properly eluting from the selected column with the current separation method. Additionally, hydrogen sulfide and ammonia have overlapping peak windows, which could impact quantification. Ongoing experiments aim to address the peak shape and overlapping via the separation method and hardware selection. Sample preparation reproducibility experiments used stock solution containing equal volumes of a non- interactive mixture of methanol, ethanol, and isopropanol. Mass spectrum ion traces were used to identify and quantify all three alcohols. Peaks were automatically detected, identified, and integrated through the mass spectra detection and processing parameters. Calibration response curves and check standards were used to evaluate the validity of the sample preparation procedure. Figure 2 shows the methanol chromatogram peak area versus total headspace dilution volume transferred from the alcohol mixture vial. The calibration response curves and check standards validate sample preparation procedure. Continuing data analysis efforts are working towards correlating the peak area and instrument response factor to the headspace analyte concentration and condensed phase composition. Static headspace gas chromatography theory relies on Dalton’s law, Raoult’s law, Henry’s Law, and the Kolb and Ettre equation to associate peak area to the analyte composition in a non-ideal solution. Equation 1 is a simplified expression derived from the aforementioned theories. Future experiments involve liquid injections of the individual stock solutions, liquid and headspace analysis of various stock solution combinations, and the addition of regolith simulants to the mixtures. Temperature is another variable expected to affect reaction rates and will be explored.

Cecilia L. Amick↗

NO2 Total and Tropospheric Vertical Column Densities from OMI on EOS Aura: Update

The Ozone Monitoring Instrument (OMI), which is on the EOS AURA satellite, retrieves vertical column densities (VCDs) of NO2, along with those of several other trace gases. The relatively high spatial resolution and daily global coverage of the instrument make it particularly well-suited to monitoring tropospheric pollution at scales on the order of 20 km. The OMI NO2 algorithm distinguishes polluted regions from background stratospheric NO2 using a separation algorithm that relies on the smoothly varying stratospheric NO2 and estimations of both stratospheric and tropospheric air mass factors (AMFs). Version 1 of OMI NO2 data has been released for public use. An overview of OMI NO2 data, some recent results and a description of the improvements for version 2 of the algorithm will be presented.

Gleason, J.F.↗

High Resolution Observations of Drop Size Distribution for GPM Ground Validation

During the Mid-latitude Continental Convective Cloud Experiment (MC3E), NASA's GPM GV Disdrometer and Radar Observations of Precipitation (DROP) Facility deployed an array of disdrometers and rain gauges in northern Oklahoma to sample, with high resolution, the drop size distribution for use in development of precipitation retrieval algorithms for the GPM core satellites. The DROP Facility instruments deployed during MC3E consisted of 16 autonomous Parsivel units, 5 two-dimensional video disdrometers (2dvds), a vertically pointing K band radar, and 32 tipping bucket rain gauges. There were several rainfall events during MC3E in which rain drops exceeding 6 mm in diameter were recorded. The disdrometer array revealed large rain drops with diameters exceeding 6 mm and 8 mm during two separate stratiform and convective rainfall events, respectively. The NPOL radar, which was scanning in high resolution RHI mode (every 40 sec) over the disdrometer array during the stratiform event, indicated a 1 km thick bright band with a differential reflectivity column of 2-3 dB extending below the melting layer to the surface where the large drops were recorded by the 2dvds. These large drops are important for GPM since they can have a great impact upon satellite precipitation retrieval, especially near the ground and below heavy convective rainfall cores where satellites have had problems depicting the rainfall.

Gatlin, Patrick N.↗

Assimilation of satellite microwave observations over the rainbands of tropical cyclones

A novel Bayesian Monte Carlo integration (BMCI) technique was developed to retrieve geophysical variables from satellite microwave radiometer data in the presence of tropical cyclones. The BMCI technique includes three steps: generating a stochastic database, simulating satellite brightness temperatures using a radiative transfer model, and retrieving geophysical variables such as profiles of temperature, relative humidity, and cloud liquid and ice water content from real observations. The technique also provides uncertainty estimates for each retrieval and can output the error covariance matrix of selected parameters. The measurements from the Advanced Technology Microwave Sounder (ATMS) on board Suomi National Polar-Orbiting Partnership (Suomi NPP) and the Global Precipitation Measurement (GPM) Microwave Imager (GMI) were used as input. A new technique was developed to correct the ATMS and GMI observations for the beam-filling effect, which is due to small-scale variability of precipitation and clouds when compared with the instrument footprint and also the nonlinear relation between the brightness temperature and precipitation. In addition, the assimilation of the BMCI retrievals into the NASA GEOS model is discussed for Hurricane Maria. The results show that assimilating the BMCI retrievals can influence the dynamical features of the cyclone, including a stronger warm core, a symmetric eye, and vertically aligned wind columns. Two possible factors that may limit the impact of the BMCI retrievals include 1) the resolution of the model (about 25 km), which was too coarse to show the potential of the BMCI data in improving the representation of tropical storms in the model forecast, and 2) the data assimilation system not being able to consider vertically correlated observation errors.

Isaac Moradi↗

Does UV instrumentation effectively measure ozone abundance?

Measurements of O3 on Mars provide significant information about the chemistry and composition of the atmosphere, including long-term changes. The most extensive and accurate data were inferred from the Mariner 9 UV spectrometer experiment. Mars O3 shows strong seasonal and latitudinal variation, with column abundances ranging from 0.2 microns at equatorial latitudes to 60 microns over the northern winter polar latitudes (1 micron-atm is a column abundance of 2.689 x 10(exp 15) molecules cm(exp-2)). The Mariner 9 UV spectrometer scanned from 2100 to 3500 Angstroms in one of its two spectral channels every 3 seconds with a spectral resolution of 15 Angstroms and an effective field-of-view of approximately 300 km(exp 2). Measurements were made for almost half a Martian year, with winter and spring in the Northern Hemisphere and summer and fall in the Southern Hemisphere. The detectability limit of the spectrometer was approximately 3 microns of ozone. The UV spectrometer on Mariner 9 was incapable of penetrating the dust during dust storms; the single-scattering albedo and phase function of airborne dust and cloud ice are not known to the degree required to extract the small UV signal reflected up from near the surface. The reflectance spectroscopy technique would also have difficulty detecting the total column abundance of O3 in cases where large dust abundances exist together with the polar hood, especially at high latitudes where large solar zenith angles magnify those optical depths; yet these cases would contain the maximum O3, based on theoretical results. It is quite possible that the maximum O3 column abundance observed by Mariner 9 of 60 microns is common. In fact, larger quantities may exist in some of the colder areas with optically thick clouds and dust. As the Viking period often had more atmospheric dust loading than did that of Mariner 9, the reflectance spectroscopy technique may even have been incapable of detecting the entire O3 column abundance during much of the Mars year that Viking observed, particularly at high latitudes.

Lindner, Bernhard Lee↗

Results of Detailed Modeling of the Narrow-Line Region of Seyfert Galaxies

We present model line profiles of [O II] lambda3727, [Ne III] lambda3869, [O I] lambda5007, [Fe VII] lambda6087, [Fe X] lambda6374, [O I] lambda6300, H(alpha) lambda6563, and [S 2] lambda6731. The profiles presented here illustrate explicitly the pronounced effects that collisional de-excitation, and that spatial variations in both the ionization parameter and cloud column density, have on Narrow-Line Region (NLR) model profiles. The above effects were included only qualitatively in a previous analytical treatment by Moore and Cohen. By making a direct correspondence between these model profiles and the analytical model profiles of Moore and Cohen, and by comparing with the observed profiles presented in a companion paper and also with those presented elsewhere in the literature, we strengthen some of the conclusions of Moore and Cohen. Most notably, we argue for constant ionization parameter, uniformly accelerated outflow of clouds that are individually stratified in ionization, and the interpretation of emission-line width correlations with ionization potential as a column density effect. For comparison with previous observational studies, such as our own in a companion paper, we also calculate profile parameters for some of the models, and we present and discuss the resulting line width correlations with critical density (n(sub cr)) and Ionization Potential (IP). Because the models we favor are those that produce extended profile wings as observed in high spectral resolution studies, the line width correlations of our favoured models are of particular interest. Line width correlations with n(sub cr) and/or IP result only if the width parameter is more sensitive to extended profile wings than is the Full Width at Half-Maximum (FWHM). Correlations between FWHM and n(sub cr) and/or IP result only after convolving the model profiles with a broad instrumental profile that simulates the lower spectral resolution used in early observational studies. The model in agreement with the greatest number of observational considerations has electron density decreasing outward from n(sub e) approx. equals 10(exp 6)/cu cm to n(sub e) approx. equals 10(exp 2)/cu cm and, due to collisional de-excitation effects in the lowest velocity clouds, it generates broad flat-topped profile peaks in the lines of lowest critical density (e.g., [O II] lambda3727 and [S II] lambda(lambda)6716, 6731). Because the observed profile peaks of both low and high critical density lines are often very similar, our favored model requires a contribution to NLR emission-line spectra from low-velocity, low-density, and low-ionization gas not included in the model NLR.

Moore, David↗

CANOZE measurements of the Arctic ozone hole

In CANOZE 1 (Canadian Ozone Experiment), a series of 20 ozone profile measurements were made in April, 1986 from Alert at 82.5 N. CANOZE is the Canadian program for study of the Arctic winter ozone layer. In CANOZE 2, ozone profile measurements were made at Saskatoon, Edmonton, Churchill and Resolute during February and March, 1987 with ECC ozonesondes. Ground based measurements of column ozone, nitrogen dioxide and hydrochloric acid were conducted at Saskatoon. Two STRATOPROBE balloon flights were conducted on February 26 and March 19, 1987. Two aerosol flights were conducted by the University of Wyoming. The overall results of this study will be reported and compared with the NOZE findings. The results from CANOZE 3 in 1988, are also discussed. In 1988, as part of CANOZE 3, STRATOPROBE balloon flights were conducted from Saskatchewan on January 27 and February 13. A new lightweight infrared instrument was developed and test flown. A science flight was successfully conducted from Alert (82.5 N) on March 9, 1988 when the vortex was close to Alert; a good measurement of the profile of nitric acid was obtained. Overall, the Arctic spring ozone layer exhibits many of the features of the Antarctic ozone phenomenon, although there is obviously not a hole present every year. The Arctic ozone field in March, 1986 demonstrated many similarities to the Antarctic ozone hole. The TOMS imagery showed a crater structure in the ozone field similar to the Antarctic crater in October. Depleted layers of ozone were found in the profiles around 15 km, very similar to those reported from McMurdo. Enhanced levels of nitric acid were measured in air which had earlier been in the vortex. The TOMS imagery for March 1987 did not show an ozone crater, but will be examined for an ozone crater in February and March, 1988, the target date for the CANOZE 3 project.

Evans, W. F. J.↗

Improved titanium-44 purification process for establishing a high apparent molar activity titanium-44/scandium-44 generator

44 Sc-radiopharmaceuticals are gaining more interest but still lack availability. The proof of principle of a 44 Ti/ 44 Sc generator, which can produce 44 Sc daily, has been established but with some limitations and drawbacks. Despite recent advances, separation of 44 Ti from massive quantities of scandium target material is still cumbersome. Here, in this work, the improved radiochemical separation of 44 Ti from residual scandium target material was carried out by precipitation of Sc with fluoride ions. Furthermore, two approaches were used to set up a high apparent molar activity small-scale generator. The first method relied on extraction chromatography for fine purification using a DGA resin, followed by loading of the purified 44 Ti onto a ZR resin column. In the second method, 44 Ti was loaded on the ZR resin directly after the precipitation step. This second method was used to set up a generator of 370 kBq and evaluate by radiolabeling. An apparent molar activity of 2 MBq/nmol was obtained for the radiolabeling with DOTA, the most common and suitable chelate for scandium. This result is comparable with previously published data on 44m/44 Sc.

44Sc↗

Raw tensiometer soil matric potential data, from Oct 2017-Jun 2020 in Manaus, Brazil

This data package contains raw output from two Campbell Scientific CR1000 data loggers each connected to three UMS T4e tensiometer sensors in Manaus, Brazil. Tensiometers at each data logger location were installed to depths of 10 cm, 20 cm and 50 cm below the ground surface for the purpose of measuring soil matric potential at each depth. “Station 3” tensiometers were installed at approximately 2°36'31.68"S, 60°12'34.70"W. “Station 4” tensiometers were installed at approximately 2°36'32.46"S, 60°12'34.92"W. The files “tensio3.edit.202109.csv” and “tensio4.edit.202109.csv” contain raw data (with invalid data removed). A text editor will be required to view the raw files in .csv (comma-separated values) format. Data processing was limited to: 1) Editing column headers for clarity; 2) Applying a correction that converts voltage read by the data loggers to pressure units (kPa); 3) removing all data greater than 50 kPa and less than -115 kPa; 4) Adding columns entitled “Caution.10cm”, “Caution.20cm” and “Caution.50cm” that contains values of either “NA” or “Caution”, the latter of which is applied when data exceeds the manufacturer reported data validity range of less than -85 kPa to suggest use of these data with caution; 5) Adding columns entitled “Invalid.10cm”, “Invalid.20cm”, and “Invalid.50cm” that contains values of either “NA” or “Invalid”, the latter of which is applied when data accuracy is deemed compromised due to the introduction of air bubbles into the instrument. Data marked “Invalid” may still indicate general trends of wet/high matric potential and dry/low matric potential, but values are inaccurate and dry/low matric potential values are likely not low enough. Wet/high matric potential values are likely to be more accurate than dry/low matric potential values; 6) Data format changed from .dat to .csv. This research was performed as a part of the NGEE Tropics project, which aims to advance model predictions of tropical forest carbon cycle responses to a changing climate over the 21st Century.

54 ENVIRONMENTAL SCIENCES↗