Imaging Valley Excitons in a 2D Semiconductor with Scanning Tunneling Microscope-Induced Luminescence

Valley excitons dominate the optoelectronic response of transition-metal dichalcogenides and are drastically affected by structural and environmental inhomogeneities localized in these materials. Critical to understanding and controlling these nanoscale excitonic changes is the ability to correlate the imaging of excitonic states with crystalline structures on the atomic scale. Here, in this study, we apply scanning tunneling microscope-induced luminescence microscopy to image valley excitons in a semiconducting transition-metal dichalcogenide monolayer decoupled by a 10 nanometer-thick hexagonal-boron-nitride flake incorporated in a lateral homojunction on an Au electrode surface. This design enables the observation of chiral excitonic emission arising from neutral and charged valley excitons of the monolayer semiconductor at ambipolar voltages with a quantum efficiency up to similar to ~10 -5 photon/electron. The measured light helicity demonstrates considerable circular polarization dependent on the sample voltage, reaching as much as 40%. The real-space luminescence imaging maps$-$at subnanometer resolution$-$of the valley excitons reveal striking spatial variations associated with localized inhomogeneities, including surface impurities and possibly nanoscale dielectric and/or potential disorders in the monolayer. Our study introduces a promising format for 2D materials to explore and tailor their optoelectronic processes at the atomic scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion Mobility – Mass Spectrometry Rapid Imaging of Special Nuclear Materials

Robot Nose will use new fast data throughput methods and experience with laser microfocus to dramatically improve the speed and spatial resolution of an established instrument, making it a useful tool for imaging special nuclear materials (SNM). Mass spectrometry imaging instruments have traditionally been too slow and mass alone is generally an insufficient measurement for organic analyses. This situation was markedly improved by Ionwerks Inc., who pioneered the combination of ion mobility with mass spectrometry imaging. In 2D mobility-mass plots, clearly identifiable trend lines can be selected and reduced to 1D mass spectra without isobaric interferences. This is a major advantage over other imaging mass spectrometers that generally cannot distinguish isobars without custom-built lasers or high voltage accelerators. Special nuclear material (SNM) contains substantial fissile isotopes, particularly 233U, 235U, and 239Pu. A complete forensic analysis of SNM therefore requires quantitative isotopic measurement – often through some form of mass spectrometry. SNM contaminated with inclusions such as pollen grains can help identify its prior locations. The project team is presently working on an approach to allow rapid screening of 1-3 cm diameter thin samples of such material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface Imaging Skin Friction Instrument and Method

A surface imaging skin friction instrument allowing 2D resolution of spatial image by a 2D Hilbert transform and 2D inverse thin-oil film solver, providing an innovation over prior art single point approaches. Incoherent, monochromatic light source can be used. The invention provides accurate, easy to use, economical measurement of larger regions of surface shear stress in a single test.

Brown, James L.↗

TomoEncoders: 3D Autoencoders for feature extraction in X-ray tomography

Real-time steering of time-resolved or in-situ X-ray tomography requires capturing changes in morphological descriptors in a sample (e.g., porosity, particle size, and crack width) during continuous data acquisition. Image segmentation (2D or3D) followed by quantitative measurement is the conventional method for tracking changes in these descriptors with respect to a previous time-step or a 3D search in a volume. However, image segmentation is expensive. As a faster and unsupervised alternative, a feature-extraction approach using a convolutional autoencoders was developed, where the latent space of the encoder responds to relative changes in morphology with-out prior knowledge of the morphological descriptors.

TEKAWADE, ANIKET↗

Diffraction limited infrared images of the binary star T Tauri

High-resolution images of T Tau and its infrared companion have been reconstructed from near- and midinfrared data collected at the Hale 5-m telescope. The near-infrared (1-5 microns) results were obtained by 2D speckle imaging and the midinfrared (10-20 microns) results were derived from shift-and-add procedures applied to slit scans. The spectral energy distributions of the separated components were constructed from 1- to 20-micron data collected in less than half a year (September 1990 to January 1991). The spectral energy distribution of the optical component (T Tau N) is interpreted as containing two distinct constituents, a photosphere and a surrounding disk of circumstellar material. Measurements at a number of infrared wavelengths over the period December 1985 to January 1991 show a 2-mag color-independent change in the brightness of the infrared component (T Tau S). It is proposed that this may have been caused by an increase in accretion onto T Tau S and model the spectral energy distribution of T Tau S as being dominated by an accretion disk.

Ghez, A. M.↗

A General Materials Data Science Framework for Quantitative 2D Analysis of Particle Growth from Image Sequences

Abstract Phase transformations are a challenging problem in materials science, which lead to changes in properties and may impact performance of material systems in various applications. We introduce a general framework for the analysis of particle growth kinetics by utilizing concepts from machine learning and graph theory. As a model system, we use image sequences of atomic force microscopy showing the crystallization of an amorphous fluoroelastomer film. To identify crystalline particles in an amorphous matrix and track the temporal evolution of the particle dispersion, we have developed quantitative methods of 2D analysis. 700 image sequences were analyzed using a neural network architecture, achieving 0.97 pixel-wise classification accuracy as a measure of the correctly classified pixels. The growth kinetics of isolated and impinged particles were tracked throughout time using these image sequences. The relationship between image sequences and spatiotemporal graph representations was explored to identify the proximity of crystallites from each other. The framework enables the analysis of all image sequences without the requirement of sampling for specific particles or timesteps for various materials systems.

36 MATERIALS SCIENCE↗

Real time quantitative imaging for semiconductor crystal growth, control and characterization

A quantitative real time image processing system has been developed which can be software-reconfigured for semiconductor processing and characterization tasks. In thermal imager mode, 2D temperature distributions of semiconductor melt surfaces (900-1600 C) can be obtained with temperature and spatial resolutions better than 0.5 C and 0.5 mm, respectively, as demonstrated by analysis of melt surface thermal distributions. Temporal and spatial image processing techniques and multitasking computational capabilities convert such thermal imaging into a multimode sensor for crystal growth control. A second configuration of the image processing engine in conjunction with bright and dark field transmission optics is used to nonintrusively determine the microdistribution of free charge carriers and submicron sized crystalline defects in semiconductors. The IR absorption characteristics of wafers are determined with 10-micron spatial resolution and, after calibration, are converted into charge carrier density.

Wargo, Michael J.↗

Spatio-Temporal Video Segmentation with Shape Growth or Shrinkage Constraint

We propose a new method for joint segmentation of monotonously growing or shrinking shapes in a time sequence of noisy images. The task of segmenting the image time series is expressed as an optimization problem using the spatio-temporal graph of pixels, in which we are able to impose the constraint of shape growth or of shrinkage by introducing monodirectional infinite links connecting pixels at the same spatial locations in successive image frames. The globally optimal solution is computed with a graph cut. The performance of the proposed method is validated on three applications: segmentation of melting sea ice floes and of growing burned areas from time series of 2D satellite images, and segmentation of a growing brain tumor from sequences of 3D medical scans. In the latter application, we impose an additional intersequences inclusion constraint by adding directed infinite links between pixels of dependent image structures.

Segmentation↗

Centimeter human skeleton pose estimation

A method, apparatus and system for human skeleton pose estimation includes synchronously capturing images of a human moving through an area from a plurality of different points of view, for each of the plurality of captured images, determining a bounding box that bounds the human in the captured image and identifying pixel locations of the bounding box in the image, for each of the plurality of captured images, determining 2D and single-view 3D skeletons from the pixel locations of the bounding box, determining a first, multi-view 3D skeleton using a combination of the 2D and single-view 3D skeletons, and optimizing the first, multi-view 3D skeleton to determine a final 3D skeleton pose for the human. The method, apparatus and system can further include illuminating the area with structured light during the capturing of the images of the human moving through the area.

Brookshire, Jonathan D.↗

Left ventricular endocardial surface detection based on real-time 3D echocardiographic data

OBJECTIVE: A new computerized semi-automatic method for left ventricular (LV) chamber segmentation is presented. METHODS: The LV is imaged by real-time three-dimensional echocardiography (RT3DE). The surface detection model, based on level set techniques, is applied to RT3DE data for image analysis. The modified level set partial differential equation we use is solved by applying numerical methods for conservation laws. The initial conditions are manually established on some slices of the entire volume. The solution obtained for each slice is a contour line corresponding with the boundary between LV cavity and LV endocardium. RESULTS: The mathematical model has been applied to sequences of frames of human hearts (volume range: 34-109 ml) imaged by 2D and reconstructed off-line and RT3DE data. Volume estimation obtained by this new semi-automatic method shows an excellent correlation with those obtained by manual tracing (r = 0.992). Dynamic change of LV volume during the cardiac cycle is also obtained. CONCLUSION: The volume estimation method is accurate; edge based segmentation, image completion and volume reconstruction can be accomplished. The visualization technique also allows to navigate into the reconstructed volume and to display any section of the volume.

Non-NASA Center↗

Nonlinear Nano‐Imaging of Interlayer Coupling in 2D Graphene‐Semiconductor Heterostructures

The emergent electronic, spin, and other quantum properties of 2D heterostructures of graphene and transition metal dichalcogenides are controlled by the underlying interlayer coupling and associated charge and energy transfer dynamics. However, these processes are sensitive to interlayer distance and crystallographic orientation, which are in turn affected by defects, grain boundaries, or other nanoscale heterogeneities. This obfuscates the distinction between interlayer charge and energy transfer. Here, nanoscale imaging in coherent four‐wave mixing (FWM) and incoherent two‐photon photoluminescence (2PPL) is combined with a tip distance‐dependent coupled rate equation model to resolve the underlying intra‐ and inter‐layer dynamics while avoiding the influence of structural heterogeneities in mono‐ to multi‐layer graphene/WSe 2 heterostructures. With selective insertion of hBN spacer layers, it is shown that energy, as opposed to charge transfer, dominates the interlayer‐coupled optical response. From the distinct nano‐FWM and ‐2PPL tip‐sample distance‐dependent modification of interlayer and intralayer relaxation by tip‐induced enhancement and quenching, an interlayer energy transfer time of τ ET ≈ ( 0 . 35 − 0.15 + 0.65 ) $\tau _{\rm ET} \approx (0.35^{+0.65}_{-0.15})$ ps consistent with recent reports is derived. As a local probe technique, this approach highlights the ability to determine intrinsic sample properties even in the presence of large sample heterogeneity.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Imaging the Shallow Structure of the Yucca Flat at the Source Physics Experiment Phase II Site with Horizontal-to-Vertical Spectral Ratio Inversion and a Large- N Seismic Array

The Source Physics Experiment (SPE) is a series of chemical explosions at the Nevada National Security Site (NNSS) with the goal of understanding seismic-wave generation and propagation of underground explosions. To understand explosion source physics, accurate geophysical models of the SPE site are needed. Here, we utilize a large-N seismic array deployed at the SPE phase II site to generate a shallow subsurface model of shear-wave velocity. The deployment consists of 500 geophones and covers an area of, approximately, 2.5 × 2 km. The array is located in the Yucca Flat in the northeast corner of the NNSS, Nye County, Nevada. Using ambient-noise recordings throughout the large-N seismic array, we calculate horizontal-to-vertical spectral ratios (HVSRs) across the array. We obtain 2D seismic images of shear-wave velocities across the SPE phase II site for the shallow structure of the basin. In this work the results clearly image two significant seismic impedance interfaces at ~150–500 and ~350–600 m depth. The shallower interface relates to the contrast between Quaternary alluvium and Tertiary volcanic rocks. The deeper interface relates to the contrast between Tertiary volcanic rocks and the Paleozoic bedrock. The 2D subsurface models support and extend previous understanding of the structure of the SPE phase II site. This study shows that the HVSR method in conjunction with a large-N seismic array is a quick and effective method for investigating shallow structures.

58 GEOSCIENCES↗

NASA Tech Briefs, November 2009

Topics covered include: Cryogenic Chamber for Servo-Hydraulic Materials Testing; Apparatus Measures Thermal Conductance Through a Thin Sample from Cryogenic to Room Temperature; Rover Attitude and Pointing System Simulation Testbed; Desktop Application Program to Simulate Cargo-Air-Drop Tests; Multimodal Friction Ignition Tester; Small-Bolt Torque-Tension Tester; Integrated Spacesuit Audio System Enhances Speech Quality and Reduces Noise; Hardware Implementation of a Bilateral Subtraction Filter; Simple Optoelectronic Feedback in Microwave Oscillators; Small X-Band Oscillator Antennas; Free-Space Optical Interconnect Employing VCSEL Diodes; Discrete Fourier Transform Analysis in a Complex Vector Space; Miniature Scroll Pumps Fabricated by LIGA; Self-Assembling, Flexible, Pre-Ceramic Composite Preforms; Flight-speed Integral Image Analysis Toolkit; Work Coordination Engine; Multi-Mission Automated Task Invocation Subsystem; Autonomously Calibrating a Quadrupole Mass Spectrometer; Determining Spacecraft Reaction Wheel Friction Parameters; Composite Silica Aerogels Opacified with Titania; Multiplexed Colorimetric Solid-Phase Extraction; Detecting Airborne Mercury by Use of Polymer/Carbon Films; Lattice-Matched Semiconductor Layers on Single Crystalline Sapphire Substrate; Pressure-Energized Seal Rings to Better Withstand Flows; Rollerjaw Rock Crusher; Microwave Sterilization and Depyrogenation System; Quantifying Therapeutic and Diagnostic Efficacy in 2D Microvascular Images; NiF2/NaF:CaF2/Ca Solid-State High-Temperature Battery Cells; Critical Coupling Between Optical Fibers and WGM Resonators; Microwave Temperature Profiler Mounted in a Standard Airborne Research Canister; Alternative Determination of Density of the Titan Atmosphere; Solar Rejection Filter for Large Telescopes; Automated CFD for Generation of Airfoil Performance Tables; Progressive Classification Using Support Vector Machines; Active Learning with Irrelevant Examples; A Data Matrix Method for Improving the Quantification of Element Percentages of SEM/EDX Analysis; Deployable Shroud for the International X-Ray Observatory; Improved Model of a Mercury Ring Damper; Optoelectronic pH Meter: Further Details; X-38 Advanced Sublimator; and Solar Simulator Represents the Mars Surface Solar Environment.

Source record↗

Imaging of surface acoustic waves on GaAs using 2D confocal Raman microscopy and atomic force microscopy

Surface acoustic wave devices have been fabricated on a GaAs (100) substrate to demonstrate the capability of 2D Raman microscopy as an imaging technique for acoustic waves on the surface of a piezoelectric substrate. Surface acoustic waves are generated using a two-port interdigitated transducer platform, which is modified to produce surface standing waves. We have derived an analytical model to relate Raman peak broadening to the near-surface strain field of the GaAs surface produced by the surface acoustic waves. Additionally, atomic force microscopy is used to confirm the presence of a standing acoustic wave, resolving a total vertical displacement of 3 nm at the antinode of the standing wave. Stress calculations are performed for both imaging techniques and are in good agreement, demonstrating the potential of this Raman analysis.

47 OTHER INSTRUMENTATION↗

Development of a Large Field-of-View PIV System for Rotorcraft Testing in the 14- x 22-Foot Subsonic Tunnel

A Large Field-of-View Particle Image Velocimetry (LFPIV) system has been developed for rotor wake diagnostics in the 14-by 22-Foot Subsonic Tunnel. The system has been used to measure three components of velocity in a plane as large as 1.524 meters by 0.914 meters in both forward flight and hover tests. Overall, the system performance has exceeded design expectations in terms of accuracy and efficiency. Measurements synchronized with the rotor position during forward flight and hover tests have shown that the system is able to capture the complex interaction of the body and rotor wakes as well as basic details of the blade tip vortex at several wake ages. Measurements obtained with traditional techniques such as multi-hole pressure probes, Laser Doppler Velocimetry (LDV), and 2D Particle Image Velocimetry (PIV) show good agreement with LFPIV measurements.

Jenkins, Luther N.↗

AE (Acoustic Emission) for Flip-Chip CGA/FCBGA Defect Detection

C-mode scanning acoustic microscopy (C-SAM) is a nondestructive inspection technique that uses ultrasound to show the internal feature of a specimen. A very high or ultra-high-frequency ultrasound passes through a specimen to produce a visible acoustic microimage (AMI) of its inner features. As ultrasound travels into a specimen, the wave is absorbed, scattered or reflected. The response is highly sensitive to the elastic properties of the materials and is especially sensitive to air gaps. This specific characteristic makes AMI the preferred method for finding "air gaps" such as delamination, cracks, voids, and porosity. C-SAM analysis, which is a type of AMI, was widely used in the past for evaluation of plastic microelectronic circuits, especially for detecting delamination of direct die bonding. With the introduction of the flip-chip die attachment in a package; its use has been expanded to nondestructive characterization of the flip-chip solder bumps and underfill. Figure 1.1 compares visual and C-SAM inspection approaches for defect detection, especially for solder joint interconnections and hidden defects. C-SAM is specifically useful for package features like internal cracks and delamination. C-SAM not only allows for the visualization of the interior features, it has the ability to produce images on layer-by-layer basis. Visual inspection; however, is only superior to C-SAM for the exposed features including solder dewetting, microcracks, and contamination. Ideally, a combination of various inspection techniques - visual, optical and SEM microscopy, C-SAM, and X-ray - need to be performed in order to assure quality at part, package, and system levels. This reports presents evaluations performed on various advanced packages/assemblies, especially the flip-chip die version of ball grid array/column grid array (BGA/CGA) using C-SAM equipment. Both external and internal equipment was used for evaluation. The outside facility provided images of the key features that could be detected using the most advanced C-SAM equipment with a skilled operator. Investigation continued using in-house equipment with its limitations. For comparison, representative X-rays of the assemblies were also gathered to show key defect detection features of these non-destructive techniques. Key images gathered and compared are: Compared the images of 2D X-ray and C-SAM for a plastic LGA assembly showing features that could be detected by either NDE technique. For this specific case, X-ray was a clear winner. Evaluated flip-chip CGA and FCBGA assemblies with and without heat sink by C-SAM. Only the FCCGA package that had no heat sink could be fully analyzed for underfill and bump quality. Cross-sectional microscopy did not revealed peripheral delamination features detected by C-SAM. Analyzed a number of fine pitch PBGA assemblies by C-SAM. Even though the internal features of the package assemblies could be detected, C-SAM was unable to detect solder joint failure at either the package or board level. Twenty times touch ups by solder iron with 700degF tip temperature, each with about 5 second duration, did not induce defects to be detected by C-SAM images. Other techniques need to be considered to induce known defects for characterization. Given NASA's emphasis on the use of microelectronic packages and assemblies and quality assurance on workmanship defect detection, understanding key features of various inspection systems that detect defects in the early stages of package and assembly is critical to developing approaches that will minimize future failures. Additional specific, tailored non-destructive inspection approaches could enable low-risk insertion of these advanced electronic packages having hidden and fine features.

Ghaffarian, Reza↗

Evaluating Cryo–TEM Reconstruction Accuracy of Self–Assembled Polymer Nanostructures

Cryogenic transmission electron microscopy (cryo–TEM) combined with single particle analysis (SPA) is an emerging imaging approach for soft materials. However, the accuracy of SPA–reconstructed nanostructures, particularly those formed by synthetic polymers, remains uncertain due to potential packing heterogeneity of the nanostructures. In this study, the combination of molecular dynamics (MD) simulations and image simulations is utilized to validate the accuracy of cryo–TEM 3D reconstructions of self–assembled polypeptoid fibril nanostructures. Using CryoSPARC software, image simulations, 2D classifications, ab initio reconstructions, and homogenous refinements are performed. By comparing the results with atomic models, the recovery of molecular details is assessed, heterogeneous structures are identified, and the influence of extraction location on the reconstructions is evaluated. In conclusion, these findings confirm the fidelity of single particle analysis in accurately resolving complex structural characteristics and heterogeneous structures, exhibiting its potential as a valuable tool for detailed structural analysis of synthetic polymers and soft materials.

36 MATERIALS SCIENCE↗

Augmented signal processing in Liquid Argon Time Projection Chambers with a deep neural network

The Liquid Argon Time Projection Chamber (LArTPC) is an advanced neutrino detector technology widely used in recent and upcoming accelerator neutrino experiments. It features a low energy threshold and high spatial resolution that allow for comprehensive reconstruction of event topologies. In current-generation LArTPCs, the recorded data consist of digitized waveforms on wires produced by induced signal on wires of drifting ionization electrons, which can also be viewed as two-dimensional (2D) (time versus wire) projection images of charged-particle trajectories. For such an imaging detector, one critical step is the signal processing that reconstructs the original charge projections from the recorded 2D images. For the first time, we introduce a deep neural network in LArTPC signal processing to improve the signal region of interest detection. By combining domain knowledge (e.g., matching information from multiple wire planes) and deep learning, this method shows significant improvements over traditional methods. This work details the method, software tools, and performance evaluated with realistic detector simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗