Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

WE-F-16A-02: Design, Fabrication, and Validation of a 3D-Printed Proton Filter for Range Spreading

Purpose: To design, fabricate and test a 3D-printed filter for proton range spreading in scanned proton beams. The narrow Bragg peak in lower-energy synchrotron-based scanned proton beams can result in longer treatment times for shallow targets due to energy switching time and plan quality degradation due to minimum monitor unit limitations. A filter with variable thicknesses patterned on the same scale as the beam's lateral spot size will widen the Bragg peak. Methods: The filter consists of pyramids dimensioned to have a Gaussian distribution in thickness. The pyramids are 2.5mm wide at the base, 0.6 mm wide at the peak, 5mm tall, and are repeated in a 2.5mm pseudo-hexagonal lattice. Monte Carlo simulations of the filter in a proton beam were run using TOPAS to assess the change in depth profiles and lateral beam profiles. The prototypes were constrained to a 2.5cm diameter disk to allow for micro-CT imaging of promising prototypes. Three different 3D printers were tested. Depth-doses with and without the prototype filter were then measured in a ~70MeV proton beam using a multilayer ion chamber. Results: The simulation results were consistent with design expectations. Prototypes printed on one printer were clearly unacceptable on visual inspection. Prototypes on a second printer looked acceptable, but the micro-CT image showed unacceptable voids within the pyramids. Prototypes from the third printer appeared acceptable visually and on micro-CT imaging. Depth dose scans using the prototype from the third printer were consistent with simulation results. Bragg peak width increased by about 3x. Conclusions: A prototype 3D printer pyramid filter for range spreading was successfully designed, fabricated and tested. The filter has greater design flexibility and lower prototyping and production costs compared to traditional ridge filters. Printer and material selection played a large role in the successful development of the filter.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-49: Design and Fabrication of Custom 3D Printed Phantoms for Radiation Therapy Research and Quality Assurance

Purpose The rapid proliferation of affordable 3D printing techniques has enabled the custom fabrication of items ranging from paper weights to medical implants. This study investigates the feasibility of utilizing the technology for developing novel phantoms for use in radiation therapy quality assurance (QA) procedures. Methods A phantom for measuring the geometric parameters of linear accelerator (LINAC) on-board imaging (OBI) systems was designed using SolidWorks. The design was transferred to a 3D printer and fabricated using a fused deposition modeling (FDM) technique. Fiducials were embedded in the phantom by placing 1.6 mm diameter steel balls in predefined holes and securing them with silicone. Several MV and kV images of the phantom were collected and the visibility and geometric accuracy were evaluated. A second phantom, for use in the experimental evaluation of a high dose rate (HDR) brachytherapy dosimeter, was designed to secure several applicator needles in water. The applicator was fabricated in the same 3D printer and used for experiments. Results The general accuracy of printed parts was determined to be 0.1 mm. The cost of materials for the imaging and QA phantoms were $22 and $5 respectively. Both the plastic structure and fiducial markers of the imaging phantom were visible in MV and kV images. Fiducial marker locations were determined to be within 1mm of desired locations, with the discrepancy being attributed to the fiducial attachment process. The HDR phantom secured the applicators within 0.5 mm of the desired locations. Conclusion 3D printing offers an inexpensive method for fabricating custom phantoms for use in radiation therapy quality assurance. While the geometric accuracy of such parts is limited compared to more expensive methods, the phantoms are still highly functional and provide a unique opportunity for rapid fabrication of custom phantoms for use in radiation therapy QA and research.

07 ISOTOPE AND RADIATION SOURCES↗

Note: Design and construction of a multi-scale, high-resolution, tube-generated X-Ray computed-tomography system for three-dimensional (3D) imaging

The design and construction of a high resolution modular x-ray computed tomography (XCT) system is described. The approach for meeting a specified set of performance goals tailored toward experimental versatility is highlighted. The instrument is unique in its detector and x-ray source configuration, both of which enable elevated optimization of spatial and temporal resolution. The process for component selection is provided. The selected components are specified, the custom component design discussed, and the integration of both into a fully functional XCT instrument is outlined. The novelty of this design is a new lab-scale detector and imaging optimization through x-ray source and detector modularity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, simulation, fabrication, and preliminary tests of 3D CMS pixel detectors for the super-LHC

The Super-LHC upgrade puts strong demands on the radiation hardness of the innermost tracking detectors of the CMS, which cannot be fulfilled with any conventional planar detector design. The so-called 3D detector architectures, which feature columnar electrodes passing through the substrate thickness, are under investigation as a potential solution for the closest operation points to the beams, where the radiation fluence is estimated to reach 10{sup 16} n{sub eq}/cm{sup 2}. Two different 3D detector designs with CMS pixel readout electronics are being developed and evaluated for their advantages and drawbacks. The fabrication of full-3D active edge CMS pixel devices with p-type substrate has been successfully completed at SINTEF. In this paper, we study the expected post-irradiation behaviors of these devices with simulations and, after a brief description of their fabrication, we report the first leakage current measurement results as performed on wafer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Matlab Code for Multiscale Topology Optimization

This Matlab script implements a simple topology optimization algorithm that minimizes the compliance of a structure within a 3D prismatic design domain. It uses a simple linear elastic finite element solver to solve the equilibrium equations, and the optimality criterion (00) method to update the design iteratively. This functionality is identical to, or the simplest possible extension from 2D to 3D of, a 99-line Matlab code released in 2001 in a journal article by Sigmund. What is new in this code is our implementation of simple surrogate models for several truss micro-architectures, which converts this code to a multiscale design tool, whereas the original code is single-scale. The development of these surrogate models and their implementation is described in a journal article we intend to submit. We plan to include the full source code in an Appendix in this paper. The code’s primary function is as a pedagogical tool rather than as a finished software product. Sigmund’s 2001 paper describes the implementation line-by-line. We are including this updated version of the code to allow the reader to understand exactly what changes must be made to a “standard” topology optimization code to implement the surrogate models and thus multiscale design optimization.

Watts, Seth↗

CT image artifacts from brachytherapy seed implants: A postprocessing 3D adaptive median filter

Purpose: To design a postprocessing 3D adaptive median filter that minimizes streak artifacts and improves soft-tissue contrast in postoperative CT images of brachytherapy seed implantations. Methods: The filter works by identifying voxels that are likely streaks and estimating more reflective voxel intensity by using voxel intensities in adjacent CT slices and applying a median filter over voxels not identified as seeds. Median values are computed over a 5x5x5 mm region of interest (ROI) within the CT volume. An acrylic phantom simulating a clinical seed implant arrangement and containing nonradioactive seeds was created. Low contrast subvolumes of tissuelike material were also embedded in the phantom. Pre- and postprocessed image quality metrics were compared using the standard deviation of ROIs between the seeds, the CT numbers of low contrast ROIs embedded within the phantom, the signal to noise ratio (SNR), and the contrast to noise ratio (CNR) of the low contrast ROIs. The method was demonstrated with a clinical postimplant CT dataset. Results: After the filter was applied, the standard deviation of CT values in streak artifact regions was significantly reduced from 76.5 to 7.2 HU. Within the observable low contrast plugs, the mean of all ROI standard deviations was significantly reduced from 60.5 to 3.9 HU, SNR significantly increased from 2.3 to 22.4, and CNR significantly increased from 0.2 to 4.1 (all P<0.01). The mean CT in the low contrast plugs remained within 5 HU of the original values. Conclusion: An efficient postprocessing filter that does not require access to projection data, which can be applied irrespective of CT scan parameters has been developed, provided the slice thickness and spacing is 3 mm or less.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design Study Of Cyclotron Magnet With Permanent Magnet

Low energy cyclotrons for Positron emission tomography (PET) have been wanted for the production of radio-isotopes after 2002. In the low energy cyclotron magnet design, increase of magnetic field between the poles is needed to make a smaller size of magnet and decrease power consumption. The Permanent magnet can support this work without additional electric power consumption in the cyclotron. In this paper the study of cyclotron magnet design using permanent magnet is shown and also the comparison between normal magnet and the magnet which is designed with permanent magnet is shown. Maximum energy of proton is 8 MeV and RF frequency is 79.3 MHz. 3D CAD design was done by CATIA P3 V5 R18 and the All field calculations had been performed by OPERA-3D TOSCA. The self-made beam dynamics program OPTICY is used for making isochronous field and other calculations.

43 PARTICLE ACCELERATORS↗

A Novel 3D DRAM Memory Cube Architecture for Space Applications

The first mainstream products in 3D IC design are memory devices where multiple memory tiers are horizontally integrated to offer manifold improvements compared with their 2D counterparts. Unfortunately, none of these existing 3D memory cubes are ready for harsh space environments. This paper presents a new memory cube architecture for space, based on vertical integration of Commercial Off-The-Shelf (COTS), 3D stacked, DRAM memory devices with a custom Radiation-Hardened-By-Design (RHBD) controller offering high memory capacity, robust reliability and low latency.Validation and evaluation of the ASIC controller will be conducted prior to tape-out on a custom FPGA-based emulator platform integrating the 3D-stack.

Yang-Scharlotta, Jean↗

Three‐Dimensional Broadband Interferometric Mapping and Polarization (BIMAP‐3D) Observations of Lightning Discharge Processes

Abstract Following on our earlier single‐station, 2‐dimensional (2D) broadband interferometric mapping and polarization (BIMAP) observations of lightning discharges, we recently deployed two BIMAP stations at Los Alamos National Laboratory to map the lightning sources and their polarization in full 3‐dimensional (3D) space (BIMAP‐3D). The two stations are separated by 11.5‐km and each station consists of four antenna sets (instead of three for the original BIMAP) that form a Y ‐shaped array for improved interferometric performance. In this paper, we report the BIMAP‐3D system design, a generalized and analytical 2D interferometry technique for noncoplanar antenna array, a two‐stage 3D mapping technique based on geometric triangulation and baseline‐based differential time of arrival, and a technique to reconstruct the polarization orientation in 3D space by combining the 2D polarization results from the two‐station observations. Along with description of the techniques, we demonstrate and discuss the initial lightning results, including 3D maps for a hybrid intracloud and cloud‐to‐ground flash and for a normal intracloud flash, development of abnormal K‐change leaders, and polarization signatures for a K‐change leader. We find that with the two‐stage 3D mapping techniques, the sources can be located to meters accuracy for a favorable event that occurs between the two stations. We also find the polarization vectors for the example K leader are mostly orthogonal to the leader channel after the full 3D polarization analysis. The main purpose of this paper is to report the BIMAP‐3D techniques and capabilities. Detailed analysis of more specific discharge processes will be reported in later studies.

54 ENVIRONMENTAL SCIENCES↗

Battery anode design: From 1D nanostructure to 3D nanoarchitecture – Enabling next-generation energy storage technology

Recently, many studies have reported the efficacy of 1D silicon nanostructures as anode materials (mostly nanowires) due to their large surface to volume ratio which could be an advantage in terms of charging kinetics. Anode design is a crucial factor for the further development of lithium-ion battery (LIB) technology, especially in terms of achieving the high charging rate performance, as typically needed in electric vehicles (EV). 3D nanostructures have been identified as the key to dramatically enhanced charging rate of LIB, in addition to the change of materials (from carbon-based anode to silicon-based). However, existing fabrication methodologies for 3D nanostructures are inherently expensive – using advanced lithography techniques or other nanopatterning methodologies, as well as using additive manufacturing approaches. Electrospinning (as an integrated additive manufacturing methodology) may be used to produce low-cost 3D-printed fiber structures. Here, in the present study, we demonstrate the groundwork in this field of research in the past 3–4 years, which would allow the extension of this special additive manufacturing approach to reach nanoscale 3D-printed fiber structures more economically and with scalability for manufacturing. This would pave the way to achieve the order of magnitude increase in battery charging rate as needed to realize the vision of the electrification of mobility/transportation.

25 ENERGY STORAGE↗

Beam test results of 3D pixel detectors constructed with poly-crystalline CVD diamond

As a possible candidate for extremely radiation tolerant tracking devices we present a novel detector design - namely 3D detectors - based on poly-crystalline CVD diamond sensors with a pixel readout. The fabrication of recent 3D detectors as well their results in recent beam tests are presented. We measured the hit efficiency and signal response of two 3D diamond detectors with 50 × 50 μm cell sizes using pixel readout chip technologies currently used at CMS and ATLAS. In all runs, both devices attained efficiencies >98 % in a normal incident test beam of minimum ionising particles. The highest efficiency observed during the beam tests was 99.2 %.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Three-Dimensional Bubble Fluidics in Architected Porous Media

Gas bubble flows in porous media often exhibit complex and seemingly unpredictable behaviors that are difficult to control. This lack of control limits the ability to design effective devices which manage multiphase flows. Here, we show how the design of 3D printed pores can deterministically control the flow path of an injected gas stream. Open cell structures can be designed to shape the gas/liquid interface with fidelity to control how the two phases are distributed throughout a porous material. The distributed gas volume is free to interact physically and chemically with the surrounding liquid phase, an effect we exploit to create a logical control gate to redirect flows within a lattice. This also allows us to design architectures for reactive capture and aerating bioreactors, resulting in patterned boundaries which can make more effective use of the liquid and gas reagents.

3D microfluidics↗

Leveraging 3D CAD and Virtual Reality in Design of the Calcine Disposition Project - 20512

Fluor Idaho's Calcine Disposition Project (CDP) is leveraging the power of three-dimensional (3D) visualization, light detection and ranging (Lidar), and virtual reality to improve designs and worker safety. With the use of computer-aided design (CAD) modeling software, the CDP has created 3D models of the facility and systems to aid in the design, development, and operation of its retrieval and transfer system. This by itself is nothing new and has been done in industry for years. The CDP project however is taking this a few steps farther with the use of Lidar and virtual reality software. The CRP is tasked with removing a radioactive granular material from stainless steel bins located in concrete vaults that were constructed in the late 1950's and early 1960's. While construction drawings are available, it is not certain that the drawings are as-built or how accurate they truly are. Part of the project requires precise placement of equipment on to bins around multiple pipe, electrical lines, and bin stiffeners. Relying solely on the existing drawings and models created from these drawings is highly risky and prone to failure. The first step to determine the precise location and orientation of all obstructions in the vault the project will use a Lidar system to scan the vault structure and precisely locate all vault and bin components. Once this information is obtained, the data will be integrated into the CAD model. The model will then be verified, and a true as-built model developed. Precise component location, size, and orientation will be used for final design and placement of retrieval components. The second step will be to take the verified 3D model and scan data and import it into virtual reality software creating a virtual world. While some work on the project requires all work to be completed remotely due to high radiation fields, some areas have low enough radiation levels that personnel can enter and perform work. With the use of a virtual reality headset, operators and technicians will be able to enter our virtual world and become familiar with the surroundings and perform work prior to ever entering the radiation environment. This training is expected to pay dividends by improving worker efficiency, reducing errors, and improving confidence that the work can be performed as expected. It will play a key aspect in as low as reasonably achievable (ALARA) principles. An additional aspect in using the Lidar scans and virtual environment, is that it will give engineers and managers an opportunity to revisit the facility, especially radiation areas, at any time to obtain design information and measurements that may be costly or impossible to obtain once the facility transitions into radiation operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WE-AB-204-03: A Novel 3D Printed Phantom for 4D PET/CT Imaging and SIB Radiotherapy Verification

Purpose: To construct and test a 3D printed phantom designed to mimic variable PET tracer uptake seen in lung tumor volumes. To assess segmentation accuracy of sub-volumes of the phantom following 4D PET/CT scanning with ideal and patient-specific respiratory motion. To plan, deliver and verify delivery of PET-driven, gated, simultaneous integrated boost (SIB) radiotherapy plans. Methods: A set of phantoms and inserts were designed and manufactured for a realistic representation of lung cancer gated radiotherapy steps from 4D PET/CT scanning to dose delivery. A cylindrical phantom (40x 120 mm) holds inserts for PET/CT scanning. The novel 3D printed insert dedicated to 4D PET/CT mimics high PET tracer uptake in the core and lower uptake in the periphery. This insert is a variable density porous cylinder (22.12×70 mm), ABS-P430 thermoplastic, 3D printed by uPrint SE Plus with inner void volume (5.5×42 mm). The square pores (1.8×1.8 mm2 each) fill 50% of outer volume, resulting in a 2:1 SUV ratio of PET-tracer in the void volume with respect to porous volume. A matching in size cylindrical phantom is dedicated to validate gated radiotherapy. It contains eight peripheral holes matching the location of the porous part of the 3D printed insert, and one central hole. These holes accommodate adaptors for Farmer-type ion chamber and cells vials. Results: End-to-end test were performed from 4D PET/CT scanning to transferring data to the planning system and target volume delineation. 4D PET/CT scans were acquired of the phantom with different respiratory motion patterns and gating windows. A measured 2:1 18F-FDG SUV ratio between inner void and outer volume matched the 3D printed design. Conclusion: The novel 3D printed phantom mimics variable PET tracer uptake typical of tumors. Obtained 4D PET/CT scans are suitable for segmentation, treatment planning and delivery in SIB gated treatments of NSCLC.

60 APPLIED LIFE SCIENCES↗

Metabolic Vessel for Impedance Spectroscopy and Electrochemistry (MVISE): The Ground Mapping Unit for the Lunar Explorer Instrument for Space Biology Applications (LEIA)​

The BioSensor payload on the upcoming LEIA platform aboard a CLPS lander will carry yeast to the moon to study response to radiation and lunar gravity. The LEIA BioSensor is designed to monitor metabolic activity using absorbance in conjunction with alamarBlue for measuring colorimetric changes as proxy measurement for redox potential. The science data returned from small spacecraft mission modules like LEIA is limited as it relies solely on optical measurements, necessitating a corresponding ground mapping unit that is equipped with multiple electrochemical sensors for accurate mapping of the optical data and operates fully automatically. This technology development work discusses the extensive design and optimization efforts put into the ground mapping unit, MVISE. MVISE is a custom designed, 3D-printed vessel with an agitation system, with six different electrochemical sensor probes, and ports for sample collection and a pressure release valve. The sensors provide real-time data, with dry absorbance measurements aligning with LEIA flight hardware and wet measurements demonstrating invasive sensor design enabling a comparison between the two setups. The 3D printer resin was tested for mechanical robustness, biocompatibility, and resistance to autoclave sterilization. The inner walls were coated with food-grade epoxy, ensuring a smooth finish to prevent microbial lodging and dye staining. The MVISE has successfully passed a week-long leak test and is now undergoing active biology tests. The MVISE prototype will be prepared for radiation tests, with three identical units being tested for varying radiation levels and culture compositions at the NASA Space Radiation Laboratory in November 2024. The integrated sensor approach proposed in this work will enable the accurate mapping of the BioSentinel/LEIA optical flight data to six sensor parameters on the ground unit for better science data return and will enable the first effort to evaluate classical biochemical sensor measurements by comparing and contrasting their responses.

Chinmayee Govinda Raj↗

Heat loads to divertor nearby components from secondary radiation evolved during plasma instabilities

A fundamental issue in tokamak operation related to power exhaust during plasma instabilities is the understanding of heat and particle transport from the core plasma into the scrape-off layer and to plasma-facing materials. During abnormal and disruptive operation in tokamaks, radiation transport processes play a critical role in divertor/edge-generated plasma dynamics and are very important in determining overall lifetimes of the divertor and nearby components. This is equivalent to or greater than the effect of the direct impact of escaped core plasma on the divertor plate. We have developed and implemented comprehensive enhanced physical and numerical models in the upgraded HEIGHTS package for simulating detailed photon and particle transport in the evolved edge plasma during various instabilities. The paper describes details of a newly developed 3D Monte Carlo radiation transport model, including optimization methods of generated plasma opacities in the full range of expected photon spectra. Response of the ITER divertor's nearby surfaces due to radiation from the divertor-developed plasma was simulated by using actual full 3D reactor design and magnetic configurations. We analyzed in detail the radiation emission spectra and compared the emission of both carbon and tungsten as divertor plate materials. The integrated 3D simulation predicted unexpectedly high damage risk to the open stainless steel legs of the dome structure in the current ITER design from the intense radiation during a disruption on the tungsten divertor plate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robotic Assisted Non-Destructive Testing (NDT)

Mission Statement: Concrete wall characterization for structural integrity evaluation of H-Canyon exhaust tunnel using a remote controlled robotic arm with a NDT Concrete Instrument. Challenges: Rough and Curved Surfaces, Remote location. The UR5 is a collaborative robotic arm capable of: Payload: 11 lbs (5 kg), Reach: 33.5 in (850 mm), Footprint: 5.87 in (149 mm) diameter, Weight: 45.4 Ibs (20.6 kg). The force torque sensor reacts to a set value inputted by the user that can be utilized for sensitive products. This allows the UR5 to react to surfaces using the built-in function to search for a wall and orient itself normal to that plane. The Proceq Pundit 250 array is a nondestructive device that the user applies against a concrete wall and scans using ultrasonic transducers. The back wall and other defects can be show through the touchscreen. A fixture to hold the Proceq Pundit 250 array onto the UR5 robotic arm was designed and 3D printed. It includes openings for easy access to the buttons from the Pundit array as well as a reinforced structural design. The scan from the Pundit array can show the back-wall, rebars, and other defects to assist in determining the structural integrity. In order to scan, a program was made to search for the wall first. 1. The UR5 robotic arm will go to the desired location away from the wall. 2. It will then search for the wall by moving towards it slowly. 3. After contact, the force applied will slowly but steadily increase to a preset value inputted by the user. 4. The force torque sensor will use those values and communicate with the UR5 by adjusting the arm to become normal to the wall. 5. The arm will then apply force to push back the transducers on the Pundit array to avoid gaps. 6. It will then prompt the user to collect data and wait until finished. The UR5 teach pendant allows the user to program the robot to perform automated and repeatable tasks. It includes a free drive mode which allows the user to move the arm to a desired position by hand. The user can also apply restricted planes which include either stopped or slower motion to ensure safety. The concrete sample being tested includes rebars and different grades of surface roughness to understand the readings from the Proceq Pundit 250 array. Desired concrete samples are currently being fabricated that will simulate the terrain being tested.

3D PRINTING↗

Physical Models from Physical Templates Using Biocompatible Liquid Crystal Elastomers as Morphologically Programmable Inks For 3D Printing

Advanced manufacturing has received considerable attention as a tool for the fabrication of cell scaffolds however, finding ideal biocompatible and biodegradable materials that fit the correct parameters for 3D printing and guide cells to align remain a challenge. Herein, a photocrosslinkable smectic-A (Sm-A) liquid crystal elastomer (LCE) designed for 3D printing is presented, that promotes cell proliferation but most importantly induces cell anisotropy. The LCE-based bio-ink allows the 3D duplication of a highly complex brain structure generated from an animal model. Vascular tissue models are generated from fluorescently stained mouse tissue spatially imaged using confocal microscopy and subsequently processed to create a digital 3D model suitable for printing. The 3D structure is reproduced using a Digital Light Processing (DLP) stereolithography (SLA) desktop 3D printer. Synchrotron Small-Angle X-ray Diffraction (SAXD) data reveal a strong alignment of the LCE layering within the struts of the printed 3D scaffold. The resultant anisotropy of the LCE struts is then shown to direct cell growth. This study offers a simple approach to produce model tissues built within hours that promote cellular alignment.

3D cell culture↗