Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Flux Recovery of a Forward Osmosis Membrane After a Fouling Process

Wastewater treatment through Forward Osmosis (FO) membranes is a process that has been evaluated in the past years as an innovative technology for the Next Generation Life Support Systems. FO technologies are cost effective, and require very low energy consumption, but are subject to membrane fouling. Membrane fouling occurs when unwanted materials accumulate on the active side of the membrane during the wastewater treatment process, which leads to a decrease in membrane flow rates. Membrane fouling can be reversed with the use of antifoulant solutions. The aim of this study is to identify the materials that cause flow rate reduction due to membrane fouling, as well as to evaluate the flux recovery after membrane treatment using commercially available antifoulants. 3D Laser Scanning Microscope images were taken to observe the surface of the membrane. Fourier Transform Infrared (FTIR) spectrometry results identified possible compounds that cause membrane fouling and FO testing results demonstrated flow rate recovery after membrane treatment using antifoulants.

Forward osmosis↗

Development of ARGOS Offloading Assessments and Methodology for Lunar EVA Simulations

The Active Response Gravity Offload System (ARGOS) at NASA Johnson Space Center (JSC) is an analog environment that can offload pressurized suited subjects at various gravity levels. The suit is suspended from a robotic overhead crane by a cable connected to the suit via a gimbal with an adjustable pivot point. There has been increased interest in providing lunar pressurized suited training at ARGOS in preparation for lunar missions. Determination of the appropriate gimbal pivot point location for a given subject is vital for a high-fidelity and functional lunar simulation. Interactions between the pivot point location and center of gravity (CG) can result in righting moments that may lead to artificially stable or unrealistically challenging configurations. Changing the pivot point location is time consuming and repeated adjustment can result in significant loss of valuable pressurized suited time. This paper aims to share the knowledge obtained from the offloading characterization efforts during pressurized suited testing at ARGOS and document the ongoing process to define an appropriate pivot point location through iterative quantitative and qualitative assessments. The human-spacesuit CG locations for the ARGOS lunar simulation were estimated using a 3D body scan and density model combined with spacesuit hardware CAD and specifications. Early pilot testing of the gimbal revealed that setting the pivot point coincident with the modeled CG location was not always possible due to the current gimbal design, and small shifts forward and aft had noticeable effects on subject stability. Fifteen subjects performed a series of CG-related tasks in the xEMU spacesuit to assess simulation acceptability. Through iterative testing, this task list evolved to streamline the process needed to efficiently identify a suitable pivot point for a given subject. The developed methodology will be critical to determine pivot point selection for astronaut training in the xEMU ARGOS environment.

Sarah L. Jarvis↗

Development of ARGOS (Active Response Gravity Offload System) Offloading Assessments and Methodology for Lunar EVA Simulations

The Active Response Gravity Offload System (ARGOS) at NASA Johnson Space Center (JSC) is an analog environment that can offload pressurized suited subjects for various reduced gravity simulations. The suit is suspended from a robotic overhead crane by a cable connected to the suit via a gimbal with an adjustable pivot point (i.e. offload attachment). There has been increased interest in providing planetary pressurized suited training at ARGOS in preparation for lunar missions. Determination of the appropriate gimbal pivot point location for a given subject is vital for a high-fidelity functional lunar simulation. Interactions between the pivot point location and human-spacesuit center of gravity (CG) can result in righting moments that may lead to artificially stable or unrealistically challenging configurations. Changing the pivot point location is time consuming and repeated adjustment can result in loss of valuable pressurized suited time. This paper aims to share knowledge obtained from the offloading characterization efforts during pressurized suited testing at ARGOS and document the ongoing process to define an appropriate pivot point location through iterative quantitative and qualitative assessments. Human-spacesuit CG locations for the ARGOS lunar simulation were estimated using a 3D body scan and density model combined with spacesuit hardware CAD and specifications. Early pilot testing of the gimbal revealed that setting the pivot point coincident with the modeled CG location was not always possible due to the current gimbal design, and small pivot point shifts had noticeable effects on subject stability. Fourteen subjects performed a series of CG-related tasks in the Exploration Extravehicular Mobility Unit (xEMU) to assess simulation characteristics. Through iterative testing, this task list evolved to streamline the process needed to efficiently identify a suitable pivot point for a given subject. The developed methodology will be critical for pivot point selection during astronaut training in the ARGOS environment.

Sarah L. Jarvis↗

Computational Icing Analysis on NASA’s SIDRM Geometry to Investigate Collection Efficiency

Computational icing analysis results were compared to experimental icing tunnel data including aerothermal (e.g. dry air) and supercooled water droplet rime-ice conditions from tests conducted in early 2022 at the NASA Icing Research Tunnel (IRT). The Simulated Intercompressor Duct Research Model (SIDRM) test article was used in this study, and its geometry represents the inter-compressor duct region of a turbofan engine. The test article’s purpose is to study the physics of supercooled water icing and ice crystal icing. This study compared three different icing codes: FENSAP-ICE (Eulerian approach), LEWICE3D (Lagrangian approach), and GlennICE (Lagrangian approach). All three icing codes were conducted on SIDRM’s complex body flow-field and compared to different experimental supercooled water rime runs. The test article instrumentation (pressure taps, thermocouples, etc.) and 3D laser scans of final ice shapes were used to compare against the different icing code simulations. The overall objectives are to understand how the icing codes handle capturing collection efficiency on the complex test article’s unheated surfaces. In the aerothermal cases, pressure tap readings matched the CFD results, but dry air CFD underpredicted thermocouple readings. Collection efficiency results from all three icing codes matched well together on the main body leading edge, main body slope, and the strut leading edges. All three icing codes underpredicted the final ice shape using a single-shot constant ice density approach, with more difficulty coming from the strut leading edge ice shape due to the swept wing like flow field. NASA’s overall goal for this effort is to develop computational icing tools to assist in the design and certification of engines for flight in icing conditions.

Supercooled icing, SIDRM, aerodynamics, computatio↗

Anthropometric Measurement Procedures at the Anthropometry and Biomechanics Facility

The Anthropometry and Biomechanics Facility (ABF) at NASA Johnson Space Center (JSC) is the centralized source of anthropometry data at NASA for use in requirement development, engineering design, and verification of human-system integrations such as spacesuits and vehicles. To ensure the collection of consistent, accurate, and valid anthropometry data, ABF has defined anthropometric measurements and anatomical landmarks which are generally based on the Anthropometric Survey for US Army Personnel (ANSUR), but with additional measurements which have been uniquely designed for spacesuit and hardware accommodation purposes. Unlike ANSUR, NASA anthropometry measurements primarily rely on 3D body scanning, a method which allows for explicitly defining the process of collecting measurements and the quality control methods used to ensure measurement reliability. In addition to ABF’s anthropometry measurement definitions and procedures, this presentation will also compare specifics of different measurement techniques ABF uses, for example, laser scanning versus manual measurement methods (e.g., tape measure or anthropometer-based), and the benefits and considerations of each method. The evolution of ABF’s measurement process will also be addressed, as new spaceflight programs have been introduced which have required unique measurements and the need to capture body shape changes over time was identified to be critical for spacesuit fit in some instances.

Garima Gupta↗

Anthropometric Measurement Procedures at the Anthropometry and Biomechanics Facility

The Anthropometry and Biomechanics Facility (ABF) at NASA Johnson Space Center (JSC) is the centralized source of anthropometry data at NASA for use in requirement development, engineering design, and verification of human-system integrations such as spacesuits and vehicles. To ensure the collection of consistent, accurate, and valid anthropometry data, ABF has defined anthropometric measurements and anatomical landmarks which are generally based on the Anthropometric Survey for US Army Personnel (ANSUR), but with additional measurements which have been uniquely designed for spacesuit and hardware accommodation purposes. Unlike ANSUR, NASA anthropometry measurements primarily rely on 3D body scanning, a method which allows for explicitly defining the process of collecting measurements and the quality control methods used to ensure measurement reliability. In addition to ABF’s anthropometry measurement definitions and procedures, this presentation will also compare specifics of different measurement techniques ABF uses, for example, laser scanning versus manual measurement methods (e.g., tape measure or anthropometer-based), and the benefits and considerations of each method. The evolution of ABF’s measurement process will also be addressed, as new spaceflight programs have been introduced which have required unique measurements and the need to capture body shape changes over time was identified to be critical for spacesuit fit in some instances.

Garima Gupta↗

Acoustic Predictions of the Moog S-250 in Hover

Acoustic predictions were made on the Moog S-250 vehicle to assess one of NASA’s mid-fidelity prediction toolchains for Urban Air Mobility-type vehicles. Experimental data from a 60-foot hover test is used for comparison. The S-250 is an RPM-controlled vehicle in a quadcopter-type configuration with four sets of contra-rotating rotors and powered by eight independently controlled electric motors. The same type of rotor blade used on the S-250 was 3D laser scanned to enable the development of custom-made airfoil tables and more accurate blade loadings. Noise predictions at the first couple of blade-pass frequencies indicate a good comparison to experimental data.

Acoustic prediction↗

3D Fluorescent and Reflective Imaging of Whole Stardust Tracks in Aerogel

The NASA Stardust mission returned to earth in 2006 with the cometary collector having captured over 1,000 particles in an aerogel medium at a relative velocity of 6.1 km/s. Particles captured in aerogel were heated, disaggregated and dispersed along 'tracks' or cavities in aerogel, singular tracks representing a history of one capture event. It has been our focus to chemically and morphologically characterize whole tracks in 3-dimensions, utilizing solely non-destructive methods. To this end, we have used a variety of methods: 3D Laser Scanning Confocal Microscopy (LSCM), synchrotron X-ray fluorescence (SXRF), and synchrotron X-ray diffraction (SXRD). In the past months we have developed two new techniques to aid in data collection. (1) We have received a new confocal microscope which has enabled autofluorescent and spectral imaging of aerogel samples. (2) We have developed a stereo-SXRF technique to chemically identify large grains in SXRF maps in 3-space. The addition of both of these methods to our analytic abilities provides a greater understanding of the mechanisms and results of track formation.

79 ASTRONOMY AND ASTROPHYSICS↗

BEAM DYNAMICS STUDIES FOR A COMPACT CARBON ION LINAC FOR THERAPY

Feasibility of an Advanced Compact Carbon Ion Linac (ACCIL) for hadron therapy is being studied at Argonne National Laboratory in collaboration with RadiaBeam Technologies. The 45-meter long linac is designed to deliver 109 carbon ions per second with variable energy from 45 MeV/u to 450 MeV/u. S-band structure provides the acceleration in this range. The carbon beam energy can be adjusted from pulse to pulse, making 3D tumor scanning straightforward and fast. Front end accelerating structures such as RFQ, DTL and coupled DTL are designed to operate at lower frequencies. The design of the linac was accompanied with extensive end-to-end beam dynamics studies which are presented in this paper.

Plastun, A.↗

Improving Contrast and Resolution in Plant Root Imaging

Plants play a vital role in our agro-economy, serving as a food source for both humans and animals, as exploitable sources of 'green' energy, and carbon/nitrogen fixing organisms important for atmospheric health. Roots, often hidden from view, represent one of the major connections shared between plants and their environment. Enhancing our understanding of the process of root growth in the face of complex soil compositions, and abundances or shortages of both nutrients and available water, will enable researchers to develop or improve strategies to select on genetic traits that increase the likelihood of plant survival under stress. A major setback associated with the study of plant root structures in-situ has been the inability to view the root using standard optical methods. X-ray imaging has been used since the 1980's to produce images from 'simple' 2D attenuation contrast scans to 3D computed tomography generated volumes. A large majority of previous experimental analysis has been conducted with commercial x-ray systems designed for life-sciences and/or materials analysis applications. These commercial packages were never intended for use with targets composed mostly of inorganic materials resulting in information loss. We have investigated methods to optimize imaging contrast and resolution to help reveal the very small features of root systems embedded within varying soil substrates. (authors)

60 APPLIED LIFE SCIENCES↗

General Testing Setup for Hyperelastic Transducers-DEEC-Tec & Marine Renewable Energy: Preprint

Distributed embedded energy conversion technologies (DEEC-Tec), an emerging domain for ocean wave energy conversion technology, is showing promise for a range of applications. Research is being conducted at the National Renewable Energy Laboratory that leverages this domain to investigate the potential of ocean wave energy converters (WECs) constructed from hyperelastic forms of distributable and embeddable energy transducers. These transducers are available in forms such as disks, rectangles, or hexagons and can be combined in various ways to form energy-producing metamaterials and flexible WECs. DEEC-Tec, therefore, could open doors that enhance ocean wave energy conversion in ways not previously thought possible by allowing for many WEC topologies and morphologies. However, the same diversity and adaptability pose challenges for the development of these DEEC-Tec-oriented hyperelastic transducers. A commercial tensile testing setup was not found that was adaptable enough to accommodate the varied transducers while providing precise force control, range of motion, and noncontact data collection. Because of this lack, a comprehensive test rig was designed in house to be used with a 3D laser scanning device-providing contactless measurements while also allowing for different geometries and various uniaxial loadings. This paper and presentation will discuss these unique challenges and the processes for overcoming them to provide a robust and general testing setup for hyperelastic transducers, of any form, for the DEEC-Tec marine renewable energy domain.

DEEC-Tec↗

WE-DE-BRA-10: Development of a Novel Scanning Beam Low-Energy Intraoperative Radiation Therapy (SBIORT) System for Pancreatic Cancer

Purpose: Developing a compact collimator system and validating a 3D surface imaging module for a scanning beam low-energy x-ray radiation therapy (SBIORT) system that enables delivery of non-uniform radiation dose to targets with irregular shapes intraoperatively. Methods: SBIORT consists of a low energy x-ray source, a custom compact collimator module, a robotic arm, and a 3D surface imaging module. The 3D surface imaging system (structure sensor) is utilized for treatment planning and motion monitoring of the surgical cavity. SBIORT can deliver non-uniform dose distributions by dynamically moving the x-ray source assembly along optimal paths with various collimator apertures. The compact collimator utilizes a dynamic shutter mechanism to form a variable square aperture. The accuracy and reproducibility of the collimator were evaluated using a high accuracy encoder and a high resolution camera platform. The dosimetrical characteristics of the collimator prototype were evaluated using EBT3 films with a Pantak Therapax unit. The accuracy and clinical feasibility of the 3D imaging system were evaluated using a phantom and a cadaver cavity. Results: The SBIORT collimator has a compact size: 66 mm diameter and 10 mm thickness with the maximum aperture of 20 mm. The mechanical experiment indicated the average accuracy of leaf position was 0.08 mm with a reproducibility of 0.25 mm at 95% confidence level. The dosimetry study indicated the collimator had a penumbra of 0.35 mm with a leaf transmission of 0.5%. 3D surface scans can be acquired in 5 seconds. The average difference between the acquired 3D surface and the ground truth is 1 mm with a standard deviation of 0.6 mm. Conclusion: This work demonstrates the feasibility of the compact collimator and 3D scanning system for the SBIORT. SBIORT is a way of delivering IORT with a compact system that requires minimum shielding of the procedure room. This research is supported by the University of Iowa Internal Funding Initiatives.

60 APPLIED LIFE SCIENCES↗

Acquisition, preprocessing, and reconstruction of ultralow dose volumetric CT scout for organ-based CT scan planning

Purpose: Traditionally, 2D radiographic preparatory scan images (scout scans) are used to plan diagnostic CT scans. However, a 3D CT volume with a full 3D organ segmentation map could provide superior information for customized scan planning and other purposes. A practical challenge is to design the volumetric scout acquisition and processing steps to provide good image quality (at least good enough to enable 3D organ segmentation) while delivering a radiation dose similar to that of the conventional 2D scout. Methods: The authors explored various acquisition methods, scan parameters, postprocessing methods, and reconstruction methods through simulation and cadaver data studies to achieve an ultralow dose 3D scout while simultaneously reducing the noise and maintaining the edge strength around the target organ. Results: In a simulation study, the 3D scout with the proposed acquisition, preprocessing, and reconstruction strategy provided a similar level of organ segmentation capability as a traditional 240 mAs diagnostic scan, based on noise and normalized edge strength metrics. At the same time, the proposed approach delivers only 1.25% of the dose of a traditional scan. In a cadaver study, the authors’ pictorial-structures based organ localization algorithm successfully located the major abdominal-thoracic organs from the ultralow dose 3D scout obtained with the proposed strategy. Conclusions: The authors demonstrated that images with a similar degree of segmentation capability (interpretability) as conventional dose CT scans can be achieved with an ultralow dose 3D scout acquisition and suitable postprocessing. Furthermore, the authors applied these techniques to real cadaver CT scans with a CTDI dose level of less than 0.1 mGy and successfully generated a 3D organ localization map.

60 APPLIED LIFE SCIENCES↗

Enhanced Quantification of 3D Woven Composites Via Fourier Analysis and Structure Tensors Applied to CT Scans

NASA's development of advanced 3D woven carbon composites, such as HEEET and 3MDCP, represents a significant leap in materials designed to endure extreme atmospheric entry conditions. However, the internal complexity of these materials introduces a variety of structures and novel defect types. Traditional characterization methods rely on labor-intensive, manual examination of X-ray CT scans, demanding considerable time and expertise. This process, while thorough, is not sustainable for large-scale analysis and defect tracking. Addressing this critical challenge, this presentation introduces an innovative suite of automated tools and analytical techniques, pioneered by the Mars Sample Return (MSR) Earth Entry System (EES) Thermal Protection System (TPS) project. These advancements offer a more efficient and accurate approach for quantifying CT data and characterizing the defects of 3D woven composites.

Magnus Haw↗

Quantitative Characterization of 3D Woven Composites Via Fourier Analysis and Structure Tensors Applied to CT Scans

NASA's development of advanced 3D woven carbon composites, such as HEEET and 3MDCP, represents a significant leap in materials designed to endure extreme atmospheric entry conditions. However, the internal complexity of these materials introduces a variety of structures and novel defect types. Traditional characterization methods rely on labor-intensive, manual examination of X-ray CT scans, demanding considerable time and expertise. This process, while thorough, is not sustainable for large-scale analysis and defect tracking. Addressing this critical challenge, this presentation introduces an innovative suite of automated tools and analytical techniques, pioneered by the Mars Sample Return (MSR) Earth Entry System (EES) Thermal Protection System (TPS) project. These advancements offer a more efficient and accurate approach for quantifying CT data and characterizing the defects of 3D woven composites.

3D Woven↗

Scanning cross-correlator for monitoring uniform 3D ellipsoidal laser beams

The specific features of experimental implementation of a cross-correlator with a scan rate above 1600 cm s{sup -1} and a spatial delay amplitude of more than 15 mm are considered. The possibility of measuring the width of femtosecond pulses propagating in a train 300 μs in duration with a repetition rate of 1 MHz is demonstrated. A time resolution of 300 fs for the maximum time window of 50 ps is attained. The cross-correlator is aimed at testing 3D pulses of a laser driver of an electron photo-injector. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in LADAR Components and Subsystems at Raytheon

Raytheon is developing NIR sensor chip assemblies (SCAs) for scanning and staring 3D LADAR systems. High sensitivity is obtained by integrating high performance detectors with gain, i.e., APDs with very low noise Readout Integrated Circuits (ROICs). Unique aspects of these designs include: independent acquisition (non-gated) of pulse returns, multiple pulse returns with both time and intensity reported to enable full 3D reconstruction of the image. Recent breakthrough in device design has resulted in HgCdTe APDs operating at 300K with essentially no excess noise to gains in excess of 100, low NEP <1nW and GHz bandwidths and have demonstrated linear mode photon counting. SCAs utilizing these high performance APDs have been integrated and demonstrated excellent spatial and range resolution enabling detailed 3D imagery both at short range and long ranges. In the following we will review progress in real-time 3D LADAR imaging receiver products in three areas: (1) scanning 256 x 4 configuration for the Multi-Mode Sensor Seeker (MMSS) program and (2) staring 256 x 256 configuration for the Autonomous Landing and Hazard Avoidance Technology (ALHAT) lunar landing mission and (3) Photon-Counting SCAs which have demonstrated a dramatic reduction in dark count rate due to improved design, operation and processing.

Jack, Michael↗