SEARCH · Search NASA
Results for “3d Printing”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Observation of laser-driven and shock-driven preheat effects on 3D-printed, two-photon polymerization plastic lattices
Explore the source record for details and available documents.
Hybrid manufacturing of ceramic-metal composites by vat polymerization 3D printing and pulse electroplating
Not Available
Structural stability and electrochemical response of 3D printed and reactively sintered Ga-doped Li7La3Zr2O12 electrolytes
Not Available
On the effect of strain rate during the cyclic compressive loading of liquid crystal elastomers and their 3D printed lattices
Nematic liquid crystal elastomers (LCEs) are a unique class of network polymers with the potential for enhanced mechanical energy absorption and dissipation capacity over conventional network polymers because they exhibit both conventional viscoelastic behavior and soft-elastic behavior (nematic director changes under shear loading). This additional inelastic mechanism makes them appealing as candidate damping materials in a variety of applications from vibration to impact. The lattice structures made from the LCEs provide further mechanical energy absorption and dissipation capacity associated with packing out the porosity under compressive loading. Understanding the extent of mechanical energy absorption, which is the work per unit mass (or volume) absorbed during loading, versus dissipation, which is the work per unit mass (or volume) dissipated during a loading cycle, requires measurement of both loading and unloading response. Here, in this study, a bench-top linear actuator was employed to characterize the loading-unloading compressive response of polydomain and monodomain LCE polymers and polydomain LCE lattice structures with two different porosities (nominally, 62% and 85%) at both low and intermediate strain rates at room temperature. As a reference material, a bisphenol-A (BPA) polymer with a similar glass transition temperature (9 °C) as the nematic LCE (4 °C) was also characterized at the same conditions for comparing to the LCE polymers. Based on the loading-unloading stress-strain curves, the energy absorption and dissipation for each material at different strain rates (0.001, 0.1, 1, 10 and 90 s -1 ) were calculated with considerations of maximum stress and material mass/density. The strain-rate effect on the mechanical response and energy absorption and dissipation behaviors was determined. The energy dissipation ratio was also calculated from the resultant loading and unloading stress-strain curves. All five materials showed significant but different strain rate effects on energy dissipation ratio. The solid LCE and BPA materials showed greater energy dissipation capabilities at both low (0.001 s -1 ) and high (above 1 s -1 ) strain rates, but not at the strain rates in between. The polydomain LCE lattice structure showed superior energy dissipation performance compared with the solid polymers especially at high strain rates.
Thermo-mechanical deterioration and molecular degradation of 3D-printed methacrylate-based polymer in various chemical environments
The advancement of additive manufacturing (AM) has accelerated the development of stereolithographic (SLA) photo-curable resins, particularly methacrylate-based polymers, due to the ability to their high-resolution, robust mechanical properties, and suitability. However, their long-term performance in chemical environments remains poorly understood. This study investigates the extent and mechanisms of degradation on an SLA-printed methacrylate-based polymer subjected to various chemicals, including polar and non-polar solvents, as well as strongly acidic aqueous solutions over a 12-week accelerated aging period. A comprehensive analytical approach incorporating swelling kinetics, surface morphology, tensile and dynamic mechanical analysis (DMA), Fourier-transform infrared (FTIR) spectroscopy, and mass spectrometry (MS) was employed to characterize chemical absorption, structural integrity, and leached products. Results reveal that degradation severity is governed by both the polarity and reactivity of the chemical environment. Notably, exposure to 6 mol L -1 HNO₃ induced the most severe deterioration, with over threefold higher swelling compared to other media, and significant reductions in tensile strength, tensile modulus, and glass transition temperature (T g ). In contrast, specimens aged in non-polar solvents (xylene and dodecane) exhibited negligible chemical interaction and retained mechanical performance. FTIR and MS analyses identified acid-catalyzed hydrolysis of ester groups as prominent degradation pathways in acidic media, while diffusion-controlled plasticization prevailed in polar solvents. Furthermore, this study provides valuable insights into the chemical stability of SLA-printed polymers and develops predictive degradation profiles that are crucial for designing durable polymer systems for advanced industrial use.
Estimating Effective Elastic Properties Of 3D Printed Specimens Using Resonant Ultrasound Spectroscopy
Explore the source record for details and available documents.
Structure and Flow-Viscosity of Filled-Polymer-Based 3D Printing Ink: Exploration through Coarse-Grained Molecular Dynamics
The addition of nanofiller particles to a polymer matrix has long been known to enhance or modify the composite’s mechanical and rheological properties. However, quantitatively capturing such changes with molecular level simulations remains computationally challenging. Toward that goal, we performed coarse-grained molecular dynamics of a nanocomposite system at a fixed (25 vol %) filler loading under nonspecific, weak polymer–filler interactions representative of a broad class of technologically important materials. We report several interesting results, including: (1) the equilibrium chain-configuration remains Gaussian-like as in an unfilled melt; (2) smaller filler particles display a stronger tendency to cluster; (3) larger fillers act as plasticizers by reducing the entanglement density and accelerating the chain mobility; and (4) fillers enhance the tensile response modulus, with the effect being stronger for larger particles. We also simulate cluster breakup, yielding, and elongational flow under an applied time-linear tensile strain and study the flow viscosity as a function of filler-size and chain-length.
Transforming CO2 into advanced 3D printed carbon nanocomposites
Not provided.
Anomalous softening of 3D printed elastomeric foam irradiated under compressive strain
Elastomeric foam is an essential component in many industrial and technological settings, primarily as thermal insulators and as positional/mechanical support cushions. In particular, silicone foam is utilized in harsh environments due to exceptional thermal and chemical stability. Under service conditions within certain applications such material gets exposed to a high dosage of gamma radiation, which can permanently alter the material’s structural and mechanical response properties. Most studies on gamma-exposure under inert or oxidative atmosphere indicate hardening of silicone foam, which is attributed to radiation-induced enhancement in chemical cross-linking. Here we report two contrasting effects depending on whether (non-oxidative) radiation exposure is carried out with the foam under zero or finite compressive strain. While in the former case we observe radiation-hardening consistent with previous studies, in the latter case (50% porous foam under 30% uniaxial compression) we see a monotonic decrease in Young’s modulus with increasing dosage, although solvent swelling experiments on the constituent rubber indicate a net increase in cross-link density independent of the state of strain. We quantitatively model all dose-dependent data using the Ogden Hyperfoam strain-energy function within the framework of Tobolsky two-network scheme and attribute the above anomaly to a combined effect of radiation-induced thickness change (compression set) and inherent nonlinearity in the foam’s stress-strain response.
Machine learning-assisted 3D printing of thermoelectric materials of ultrahigh performances at room temperature
Optimizedviamachine learning, extrusion printed thermoelectric materials (BiSbTe) achieve an ultrahighzTof 1.3 at room temperature.
Design, simulation, and manufacturability of a micro-ion trap incorporating a 3D-printed loading zone for improved hot-ion capture
Explore the source record for details and available documents.
Vibration-Damping Properties of 3D-Printed Auxetic Structures
Two-photon polymerization is a recently developed technique that is used to print millimeter-size cellular structures with micrometer resolution. The two-photon polymerization process discussed in this paper is used to build structures to stabilize direct-drive targets that are imploded at cryogenic temperatures. These targets are supported by a very thin stalk (10 to 18 µm diameter) that can be broken (or dislodged) by vibrations that occur when the target is transported or when the cryogenic shroud is removed. And any vibration at the moment of implosion affects how precisely the target is aligned to the focus of the laser beams. Finally, this study investigates the mechanical properties of different millimeter-sized cellular auxetic structures (~0.2 g/cm 3 ) at room and cryogenic temperatures (20°C and −140°C) and how well the most promising structure dampens vibrations at room temperature.
A Novel Dosimetry Method for Small Animal Irradiators Using 3D-printed Mouse Phantoms and Alanine Dosimeters
Abstract Accurate dosimetry is a crucial component of small animal and preclinical irradiation studies. Various dosimetry options are available but fail to characterize complex geometries and variable energy spectra of modern x-ray irradiators accurately. These options also lack national/international standards of recognition. This paper presents a novel dosimetry system, Dosequate, which uses murine phantoms embedded with alanine dosimeters and paired with x-ray energy spectra corrections to deliver consistent and accurate dosimetry measurements. This study compares Dosequate measurements against a Precision X-RAD 320 internal ion chamber and the treatment planning system of an Xstrahl Small Animal Radiation Research Platform. Results demonstrate the accuracy and reproducibility of the Dosequate system, highlighting its potential for standardizing dosimetry in preclinical research throughout the industry. Results demonstrate the accuracy and reproducibility of the Dosequate system, highlighting its potential for standardizing dosimetry in preclinical research throughout the industry. The Dosequate dosimetry method provides a robust and standardized approach for measuring absorbed dose in small animal irradiators. Its accuracy, reproducibility, and ability to account for complex irradiation geometries make it a valuable tool for preclinical research. This system has the potential to significantly improve the intercomparability of studies across different facilities and enhance the reliability of results.