Search NASA⌕ Search

SEARCH · Search NASA

Results for “47 - OTHER INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

X-ray photoelectron spectroscopy of epitaxial films and heterostructures

X-ray photoelectron spectroscopy is a powerful experimental technique that yields invaluable information on a range of phenomena that occur in solids, liquids, and gasses. The binding energy and shape of a photoemission peak is sensitive not only to the atomic number, valence and orbital from which the electron is ejected, but also to complex many-body effects that accompany photoemission. Provided the influences of these different drivers of spectral line shapes can be disentangled, a great deal can be learned about the electronic structures of specific atoms in the material of interest. In addition to these largely local effects, the long-range electrostatic environment and resulting electric potential at the emitting atom have a direct effect on the measured binding energies. Furthermore, this fact opens the door to extracting information about the dependence of the valence and conduction band minima on depth below the surface, which in turn allows both vertical and lateral electrical transport data to be better understood. One purpose of this Report is to describe how the different physical forces described above impact spectral properties of complex oxide epitaxial films. This class of materials typically incorporates transition metal cations in different valences and of all the elements, these exhibit the most complex core-level spectra. A second purpose is to show how a comprehensive understanding of local physical effects in x-ray photoemission allows one to extract detailed information on internal electric fields and band edge discontinuities in heterostructures involving complex oxides from core-level line shapes.

47 OTHER INSTRUMENTATION↗

Rapid characterization of MSW and RDF feedstocks for waste-to-energy process using LIBS and ML techniques

The heterogeneity in the composition of municipal solid wastes (MSW) poses significant challenges in the production of biofuel and bioproducts. This research aims to enhance the accuracy and efficiency of waste analysis and characterization by introducing a fast characterization approach for MSW-derived refuse-derived fuels (RDF) by combining Laser-Induced Breakdown Spectroscopy (LIBS) with advanced machine learning (ML) techniques. The approach combines data pre-processing of LIBS spectra of RDF, and the development of ML models trained on domain and theory-based spectral features for predicting process parameters. These models are adept at predicting key process parameters like High Heating Value (HHV), carbon content, and volatile matter. This approach can achieve an average RRMSE of 2.13% and R 2 of 0.98 or higher for all considered parameters on testing data. This work demonstrates significant potential for improving waste sorting, processing efficiency, and environmental compliance over traditional labor- and time-intensive laboratory waste analysis and characterization.

09 BIOMASS FUELS↗

Tailoring coherent beam combined laser pulse trains for high peak and average power applications

Laser systems based on coherent beam combination (CBC) that rely on tiled pupil architecture intrinsically carry digital capabilities independently applicable to all three essential characteristics of a laser pulse: amplitude, phase and polarization. Those capabilities allow the far-field energy distribution to be flexibly tailored in real time. Operation in the femtosecond regime at high repetition rates gives access to a wide range of applications requiring both high peak and average powers. We address the task of independent peak versus average power adjustment needed for applications seeking to decouple nonlinear phenomena associated with GW peak power from the thermal load inherent to kW average power operation. The technical solutions proposed are presented in the framework of the Ecole Polytechnique XCAN CBC laser platform (61 independent channels) with an emphasis on thermal management measures implemented to ensure its nominal operation.

47 OTHER INSTRUMENTATION↗

A Bayesian framework to investigate radiation reaction in strong fields

Recent experiments aiming to measure phenomena predicted by strong-field quantum electrodynamics (SFQED) have done so by colliding relativistic electron beams and high-power lasers. In such experiments, measurements of collision parameters are not always feasible. However, precise knowledge of these parameters is required to accurately test SFQED. Here, we present a novel Bayesian inference procedure that infers collision parameters that could not be measured on-shot. This procedure is applicable to all-optical non-linear Compton scattering experiments investigating radiation reaction. The framework allows multiple diagnostics to be combined self-consistently and facilitates the inclusion of known information pertaining to the collision parameters. Using this Bayesian analysis, the relative validity of the classical, quantum-continuous and quantum-stochastic models of radiation reaction was compared for several test cases, which demonstrates the accuracy and model selection capability of the framework and highlight its robustness if the experimental values of fixed parameters differ from their values in the models.

47 OTHER INSTRUMENTATION↗

Plasma-based prism compressor design for high-intensity laser pulses

A concept for a femtosecond pulse compressor based on underdense plasma prisms is presented. An analytical model is developed to calculate the spectral phase incurred and the expected pulse compression. A 2D particle-in-cell simulation verifies the analytical model. Simulated intensities ( ∼10 16 W/cm 2 ) were orders of magnitude higher than the damage threshold for conventional gratings used in chirped pulse amplification. Theoretical geometries for compact (tens of cm scale) compressors for 1, 10 and 100 PW power levels are proposed.

47 OTHER INSTRUMENTATION↗

Thermal stress-induced depolarization compensation in wide-bandwidth, high-energy, high-repetition-rate multi-slab laser amplifiers

We present an innovative design for a two-head, gas-cooled multi-slab high-energy, high-repetition-rate amplifier aimed at mitigating thermally induced depolarization in a wide-bandwidth neodymium-doped glass gain medium. This architecture employs two quartz rotators (QRs) with opposite-handedness, strategically positioned within each multi-slab amplifier head, to enhance depolarization compensation. Theoretical modeling of this amplifier configuration demonstrates a 20× reduction in depolarization losses for a 70 mm beam operating at the central wavelength, compared to conventional approaches that utilize a single QR positioned between the amplifier heads. In addition, for a wide bandwidth source, the integration of QRs with opposite-handedness yields a 9× improvement in depolarization losses at the spectral extremes compared to the use of two QRs exhibiting the same optical handedness in both amplifier heads.

47 OTHER INSTRUMENTATION↗

Tracking Thermal Transport in Colloidal Quantum Dot Films Using in Situ Time-Resolved X-ray Diffraction

Colloidal quantum dots (QDs) and their thin films are increasingly used in electronic and photonic devices replacing traditional bulk semiconductors. However, thermal properties of QDs remain underexplored relative to device development efforts. This study shows the use of time-resolved X-ray diffraction as a contact-free method to probe the thermal response of QDs in environments representative of the active layer in QD optoelectronic devices, providing in situ insights for future thermal management strategies. Through the extraction of Debye–Waller factors on a subnanosecond time scale, we directly capture the heating and cooling of core/shell CdSe/CdS QDs following pulsed optical excitation. In a QD thin film that actively provides optical gain, the thermal conductivity is found to be as low as 0.13 W m –1 K –1 , because of the poor heat flow between close-packed QD solids. For QDs dispersed in liquids, interfacial thermal conductance dominates thermal relaxation, with a conductance of 15 MW m –2 K –1 .

36 MATERIALS SCIENCE↗

Topology-Dependent Polymer Stretching and Scission in Solution at Extreme Shear Rates

There has been significant interest in the engineering of polymer topology to control rheology and mechanical stability in dilute solutions for applications involving extreme shear rate flows. However, methods to experimentally probe properties at relevant shear rates (≈ 10 4 –10 6 s –1 ) have remained ex situ, obscuring access to measures of polymer deformation and rheology that would otherwise provide mechanistic insight into the topology-dependent properties that control their behavior in extreme shear flows. In this study, we used novel in situ small angle neutron scattering measurements in a capillary rheometer (capillary rheo-SANS) to simultaneously measure solution viscosities and polymer deformations in high shear on a series of chemically homologous topology-defined polymers including linear, randomly branched, and star-shaped molecules. We demonstrate that differences in the onset of chain stretching and shear thinning of these polymers in dilute solution are controlled primarily by differences in their molecular relaxation time. These differences correlate with differences in chain scission inferred from ex situ measurements at more extreme shear rates. Together, the results demonstrate a direct coupling between chain deformation and scission, and suggest that the dominant effect of branching as a means to impart resilience against mechanical degradation is through differences in relaxation dynamics due to branching. We anticipate that these results will provide key insights to engineer topology-controlled polymers for rheological modification, mechanical stability, and controlled mechano-chemistry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of an Attenuated Total Reflectance–Ultraviolet–Visible Probe for the Online Monitoring of Dark Solutions

Optical spectroscopy is a valuable tool for on-line monitoring of a variety of processes. Ultraviolet-visible (UV-vis) spectroscopy in particular, can monitor the concentration of analytes as well as identify speciation and oxidation state. However, it can be difficult to impossible to employ UV-vis based sensors on chemical systems that are very dark (i.e., high optical density) as exceedingly short pathlengths are required (for transmission approaches) or effective means of backscattering are needed (for reflectance approaches). Examples of processes that would benefit significantly from the use of optical sensors and encounter these challenges include used nuclear fuel recycling and molten salts with high concentrations of dissolved uranium. Utilizing an attenuated total reflectance (ATR) UV-vis approach can overcome these challenges and allow for the measurement of solutions orders of magnitude more concentrated than transmission UV-vis. However, determining ideal sensor specifications for varied processes can be time consuming and expensive. Here, in this study, we evaluate the ability for a novel ATR-UV-vis probe to measure very concentrated solutions of Co(II) and Ni(II) nitrate as well as organic dyes (methylene blue, acid red 1, and crystal violet). This sensor design provides a modular method for exploring possible “pathlengths” by altering the exposed ATR fiber length. Also studied were approaches to loading and measuring the sensor cell. These results are compared to a traditional 1 cm cuvette measured by transmission UV-vis. It was found that the ATR-UV-vis probe was capable of measuring solutions 600 times more concentrated than the 1 cm cuvette. Advanced data analysis in the form of multivariate curve resolution (MCR) was used to analyze the speciation of methylene blue over a large concentration range. The application of this novel ATR-UV-vis probe to the interrogation of dark solutions is a promising avenue for use in on-line monitoring of nuclear processes.

47 OTHER INSTRUMENTATION↗

Automated Calibration for Rapid Optical Spectroscopy Sensor Development for Online Monitoring

An automated platform has been developed to assist researchers in the rapid development of optical spectroscopy sensors to quantify species from spectral data. This platform performs calibration and validation measurements simultaneously. Real-time, in situ monitoring of complex systems through optical spectroscopy has been shown to be a useful tool; however, building calibration models requires development time, which can be a limiting factor in the case of radiological or otherwise hazardous systems. While calibration time can be reduced through optimized design of experiments, this study approached the challenge differently through automation. The ATLAS (Automated Transient Learning for Applied Sensors) platform used pneumatic control of stock solutions to cycle flow profiles through desired calibration concentrations for multivariate model construction. Additionally, the transients between desired concentrations based on flow calculations were used as validation measurements to understand model predictive capabilities. This automated approach yielded an incredible 76% reduction in model development time and a 60% reduction in sample volume versus estimated manual sample preparation and static measurements. The ATLAS system was demonstrated on two systems: a three-lanthanide system with Pr/Nd/Ho representing a use case with significant overlap or interference between analyte signatures and an alternate system containing Pr/Nd/Ni to demonstrate a use case in which broad-band corrosion species signatures interfered with more distinct lanthanide absorbance profiles. Both systems resulted in strong model prediction performance (RMSEP < 9%). Lastly, ATLAS was demonstrated as a tool to simulate process monitoring scenarios (e.g., column separation) in which models can be further optimized to account for day-to-day changes as necessary (e.g., baseline correction). Ultimately, ATLAS offers a vital tool to rapidly screen monitoring methods, investigate sensor fusion, and explore more complex systems (i.e., larger numbers of species).

47 OTHER INSTRUMENTATION↗

Advancing the Prediction of MS/MS Spectra Using Machine Learning

Tandem mass spectrometry (MS/MS) is an important tool for the identification of small molecules and metabolites where resultant spectra are most commonly identified by matching them with spectra in MS/MS reference libraries. While popular, this strategy is limited by the contents of existing reference libraries. In response to this limitation, various methods are being developed for the in silico generation of spectra to augment existing libraries. Recently, machine learning and deep learning techniques have been applied to predict spectra with greater speed and accuracy. Here, in this work, we investigate the challenges these algorithms face in achieving fast and accurate predictions on a wide range of small molecules. The challenges are often amplified by the use of generic machine learning benchmarking tactics, which lead to misleading accuracy scores. Curating data sets, only predicting spectra for sufficiently high collision energies, and working more closely with experimental mass spectrometrists are recommended strategies to improve overall prediction accuracy in this nuanced field.

47 OTHER INSTRUMENTATION↗

Dynamic motion trajectory control with nanoradian accuracy for multi-element X-ray optical systems via laser interferometry

The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore’s law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend achromat based synchrotron sources and high repetition rate X-ray free electron lasers, puts increasingly stringent requirements on stability and accuracy of X-ray optics systems. Parasitic motion errors at sub-micro radian scale in beam transport and beam conditioning optics can lead to significant loss of coherence and brightness delivered from source to experiment. To address this challenge, we incorporated optical metrology based on interferometric length and angle sensing and real-time correction as part of the X-ray optics motion control system. A prototype X-ray optics system was constructed following the optical layout of a tunable X-ray cavity. On-line interferometric metrology enabled dynamical feedback to a motion control system to track and compensate for motion errors. The system achieved sub-microradian scale performance, as multiple optical elements are synchronously and continuously adjusted. This first proof of principle measurement demonstrated both the potential and necessity of incorporating optical metrology as part of the motion control architecture for large scale X-ray optical systems such as monochromators, delay lines, and in particular, X-ray cavity systems to enable the next generation cavity-based X-ray free electron lasers.

47 OTHER INSTRUMENTATION↗

Integrated photonic encoder for low power and high-speed image processing

Abstract Modern lens designs are capable of resolving greater than 10 gigapixels, while advances in camera frame-rate and hyperspectral imaging have made data acquisition rates of Terapixel/second a real possibility. The main bottlenecks preventing such high data-rate systems are power consumption and data storage. In this work, we show that analog photonic encoders could address this challenge, enabling high-speed image compression using orders-of-magnitude lower power than digital electronics. Our approach relies on a silicon-photonics front-end to compress raw image data, foregoing energy-intensive image conditioning and reducing data storage requirements. The compression scheme uses a passive disordered photonic structure to perform kernel-type random projections of the raw image data with minimal power consumption and low latency. A back-end neural network can then reconstruct the original images with structural similarity exceeding 90%. This scheme has the potential to process data streams exceeding Terapixel/second using less than 100 fJ/pixel, providing a path to ultra-high-resolution data and image acquisition systems.

47 OTHER INSTRUMENTATION↗

Bright and durable scintillation from colloidal quantum shells

Abstract Efficient, fast, and robust scintillators for ionizing radiation detection are crucial in various fields, including medical diagnostics, defense, and particle physics. However, traditional scintillator technologies face challenges in simultaneously achieving optimal performance and high-speed operation. Herein we introduce colloidal quantum shell heterostructures as X-ray and electron scintillators, combining efficiency, speed, and durability. Quantum shells exhibit light yields up to 70,000 photons MeV −1 at room temperature, enabled by their high multiexciton radiative efficiency thanks to long Auger-Meitner lifetimes (>10 ns). Radioluminescence is fast, with lifetimes of 2.5 ns and sub-100 ps rise times. Additionally, quantum shells do not exhibit afterglow and maintain stable scintillation even under high X-ray doses (>10 9 Gy). Furthermore, we showcase quantum shells for X-ray imaging achieving a spatial resolution as high as 28 line pairs per millimeter. Overall, efficient, fast, and durable scintillation make quantum shells appealing in applications ranging from ultrafast radiation detection to high-resolution imaging.

47 OTHER INSTRUMENTATION↗

Johnson-noise-limited cancellation-free microwave impedance microscopy with monolithic silicon cantilever probes

Abstract Microwave impedance microscopy (MIM) is an emerging scanning probe technique for nanoscale complex permittivity mapping and has made significant impacts in diverse fields. To date, the most significant hurdles that limit its widespread use are the requirements of specialized microwave probes and high-precision cancellation circuits. Here, we show that forgoing both elements not only is feasible but also enhances performance. Using monolithic silicon cantilever probes and a cancellation-free architecture, we demonstrate Johnson-noise-limited, drift-free MIM operation with 15 nm spatial resolution, minimal topography crosstalk, and an unprecedented sensitivity of 0.26 zF/ √ Hz. We accomplish this by taking advantage of the high mechanical resonant frequency and spatial resolution of silicon probes, the inherent common-mode phase noise rejection of self-referenced homodyne detection, and the exceptional stability of the streamlined architecture. Our approach makes MIM drastically more accessible and paves the way for advanced operation modes as well as integration with complementary techniques.

47 OTHER INSTRUMENTATION↗

Non-linear enhancement of ultrafast X-ray diffraction through transient resonances

Diffraction-before-destruction imaging with ultrashort X-ray pulses can visualize non-equilibrium processes, such as chemical reactions, with sub-femtosecond precision in the native environment. Here, a nanospecimen diffracts a single X-ray flash before it disintegrates. The sample structure can be reconstructed from the coherent diffraction image (CDI). State-of-the-art X-ray snapshots lack high spatial resolution because of weak diffraction signal. Bleaching effects from photo-ionization significantly restrain image brightness scaling. We find that non-linear transient ion resonances can overcome this barrier if X-ray laser pulses are shorter than in most experiments. We compared snapshots from individual ≈ 100 nm Xe nanoparticles as a function of pulse duration and incoming X-ray fluence. Our experimental results and Monte Carlo simulations suggest that transient resonances can increase ionic scattering cross sections significantly beyond literature values. This provides a novel avenue towards substantial improvement of the spatial resolution in CDI in combination with sub-femtosecond temporal precision at the nanoscale.

47 OTHER INSTRUMENTATION↗

Integrated millimeter-wave cavity electro-optic transduction

Emerging communications and computing technologies will rely ever-more on expanding the useful radio frequency spectrum into the millimeter-wave and terahertz frequency range. Both classical and quantum applications would benefit from advancing integration and incorporation of millimeter-wave and electro-optic technologies into common devices, such as modulators. Here we demonstrate an integrated triply-resonant, superconducting electro-optic transducer. Our design incorporates an on-chip 107 GHz niobium titanium nitride superconducting resonator, modulating a thin-film lithium niobate optical racetrack resonator operating at telecom wavelengths. We observe a maximum photon transduction efficiency of η OE ≈ 0.82 × 10 −6 and an average single-photon electro-optic interaction rate of g 0 /2π ≈ 0.7 kHz. We also present a study and analysis of the challenges associated with the design of integrated millimeter-wave resonators and propose possible solutions to these challenges. Our work paves the way for further advancements in resonant electro-optic technologies operating at millimeter-wave frequencies.

47 OTHER INSTRUMENTATION↗