Search NASA⌕ Search

SEARCH · Search NASA

Results for “ABDOMEN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

SU-C-207B-05: Tissue Segmentation of Computed Tomography Images Using a Random Forest Algorithm: A Feasibility Study

Purpose: Develop an automated Random Forest algorithm for tissue segmentation of CT examinations. Methods: Seven materials were classified for segmentation: background, lung/internal gas, fat, muscle, solid organ parenchyma, blood/contrast, and bone using Matlab and the Trainable Weka Segmentation (TWS) plugin of FIJI. The following classifier feature filters of TWS were investigated: minimum, maximum, mean, and variance each evaluated over a pixel radius of 2n, (n = 0–4). Also noise reduction and edge preserving filters, Gaussian, bilateral, Kuwahara, and anisotropic diffusion, were evaluated. The algorithm used 200 trees with 2 features per node. A training data set was established using an anonymized patient’s (male, 20 yr, 72 kg) chest-abdomen-pelvis CT examination. To establish segmentation ground truth, the training data were manually segmented using Eclipse planning software, and an intra-observer reproducibility test was conducted. Six additional patient data sets were segmented based on classifier data generated from the training data. Accuracy of segmentation was determined by calculating the Dice similarity coefficient (DSC) between manual and auto segmented images. Results: The optimized autosegmentation algorithm resulted in 16 features calculated using maximum, mean, variance, and Gaussian blur filters with kernel radii of 1, 2, and 4 pixels, in addition to the original CT number, and Kuwahara filter (linear kernel of 19 pixels). Ground truth had a DSC of 0.94 (range: 0.90–0.99) for adult and 0.92 (range: 0.85–0.99) for pediatric data sets across all seven segmentation classes. The automated algorithm produced segmentation with an average DSC of 0.85 ± 0.04 (range: 0.81–1.00) for the adult patients, and 0.86 ± 0.03 (range: 0.80–0.99) for the pediatric patients. Conclusion: The TWS Random Forest auto-segmentation algorithm was optimized for CT environment, and able to segment seven material classes over a range of body habitus and CT protocol parameters with an average DSC of 0.86 ± 0.04 (range: 0.80–0.99).

60 APPLIED LIFE SCIENCES↗

SU-F-R-39: Effects of Radiation Dose Reduction On Renal Cell Carcinoma Discrimination Using Multi-Phasic CT Imaging

Purpose: A method to discriminate different types of renal cell carcinoma (RCC) was developed using attenuation values observed in multiphasic contrast-enhanced CT. This work evaluates the sensitivity of this RCC discrimination task at different CT radiation dose levels. Methods: We selected 5 cases of kidney lesion patients who had undergone four-phase CT scans covering the abdomen to the lilac crest. Through an IRB-approved study, the scans were conducted on 64-slice CT scanners (Definition AS/Definition Flash, Siemens Healthcare) using automatic tube-current modulation (TCM). The protocol included an initial baseline unenhanced scan, followed by three post-contrast injection phases. CTDIvol (32 cm phantom) measured between 9 to 35 mGy for any given phase. As a preliminary study, we limited the scope to the cortico-medullary phase—shown previously to be the most discriminative phase. A previously validated method was used to simulate a reduced dose acquisition via adding noise to raw CT sinogram data, emulating corresponding images at simulated doses of 50%, 25%, and 10%. To discriminate the lesion subtype, ROIs were placed in the most enhancing region of the lesion. The mean HU value of an ROI was extracted and used to discriminate to the worst-case RCC subtype, ranked in the order of clear cell, papillary, chromophobe and the benign oncocytoma. Results: Two patients exhibited a change of worst case RCC subtype between original and simulated scans, at 25% and 10% doses. In one case, the worst-case RCC subtype changed from oncocytoma to chromophobe at 10% and 25% doses, while the other case changed from oncocytoma to clear cell at 10% dose. Conclusion: Based on preliminary results from an initial cohort of 5 patients, worst-case RCC subtypes remained constant at all simulated dose levels except for 2 patients. Further study conducted on more patients will be needed to confirm our findings. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics; NIH Grant Support from: U01 CA181156.

60 APPLIED LIFE SCIENCES↗

SU-F-J-16: Planar KV Imaging Dose Reduction Study

Purpose: IGRT has become an indispensable tool in modern radiotherapy with kV imaging used in many departments due to superior image quality and lower dose when compared to MV imaging. Many departments use manufacturer supplied protocols for imaging which are not always optimised between image quality and radiation dose (ALARA). Methods: Whole body phantom PBU-50 (Kyoto Kagaku ltd., Japan) for imaging in radiology has been imaged on Varian iX accelerator (Varian Medical Systems, USA) with OBI 1.5 system. Manufacturer’s default protocols were adapted by modifying kV and mAs values when imaging different anatomical regions of the phantom (head, thorax, abdomen, pelvis, extremities). Images with different settings were independently reviewed by two persons and their suitability for IGRT set-up correction protocols were evaluated. The suitable images with the lowest mAs were then selected. The entrance surface dose (ESD) for manufacturer’s default protocols and modified protocols were measured with RTI Black Piranha (RTI Group, Sweden) and compared. Image quality was also measured with kVQC phantom (Standard Imaging, USA) for different protocols. The modified protocols have been applied for clinical work. Results: For most cases optimized protocols reduced the ESD on average by a factor of 3(range 0.9–8.5). Further reduction in ESD has been observed by applying bow-tie filter designed for CBCT. The largest reduction in dose (12.2 times) was observed for Thorax lateral protocol. The dose was slightly increased (by 10%) for large pelvis AP protocol. Conclusion: Manufacturer’s default IGRT protocols could be optimised to reduce the ESD to the patient without losing the necessary image quality for patient set-up correction. For patient set-up with planar kV imaging the bony anatomy is mostly used and optimization should focus on this aspect. Therefore, the current approach with anthropomorphic phantom is more advantageous in optimization over standard kV quality control phantoms and SNR metrics.

60 APPLIED LIFE SCIENCES↗

SU-F-J-21: Clinical Evaluation of Surface Scanning Systems in Different Treatment Locations

Purpose: To reduce imaging dose in fractionated IGRT, the ability of optical surface imaging systems (OSIS) to detect setup errors was tested. Therefore, clinical studies to evaluate for different treatment locations setup corrections derived by OSIS in comparison with x-ray image guidance in fractionated radiation therapy was performed. Methods: The setup correction accuracy of an OSIS system (AlignRT, VisionRT, London, UK) will be analysed for the 4 tumour locations Pelvis, Upper Abdomen, Thorax and Breast, 20 patients for each location in comparison to a different system (Sentinel, C-RAD, SE). For each patient, the setup corrections of the cone-beam computed tomography (CBCT) of an Elekta Versa HD linear accelerator (Elekta, Crawley, UK) is considered as gold-standard and then compared with those of the OSIS for the first ten fractions retrospectively. There were no clinical decisions made based on the surrogate system. For the OSIS, the reference surface is highly important as it represents the actual ground truth. It can be obtained either with the system itself or the surface structure delineated in the planning CT can be imported via DICOM interface. In this paper, the first results for the treatment region thorax are presented. The reference image modalities were compared. Results: Table 1 displays the difference between the setup corrections obtained with OSIS and CBCT in lateral (LAT), longitudinal (LNG) and vertical (VRT) direction for the DICOM reference image. While the median deviations are within a few millimeters, some outliers showed large deviations. Generally, the mean deviation as well as the spread was smallest in lateral and largest in vertical direction. Conclusion: Although the system allows fast, simple and non-invasive determination of setup corrections, it should be evaluated treatment region dependant. Therefore, the study is ongoing. The application of OSIS may help to reduce the imaging dose for the patient. We gratefully acknowledge the support by our colleagues from the Radiological University Clinic Heidelberg, where the study was performed. This work was funded by the Federal Ministry of Education and Research (BMBF) Germany, grant number 01IB13001B.

60 APPLIED LIFE SCIENCES↗

SU-F-J-139: Amplitude of Low Frequency Fluctuation(ALFF) and Regional Homogeneity (ReHo) Study of the Respiration Motion Control Byhypnosis

Purpose: Respiration control by hypnosis is a method in reducing the detriment to the healthy organs or organizations for patients during radiotherapy, especially for lung and abdomen cancer (Fig.1). It’s hypothesized that there exists alterations neurological brain activity during the hypnosis state of respiratory motion control in comparison with resting state. Methods: Thirteen healthy volunteers were organized to participate in a hypnosis experiment that consisted of two sectional scans of functional magnetic resonance imaging (fMRI), rest state condition (RSC) scanning and hypnosis state condition (HSC) scanning. In addition, the coronal section of the lung was scanned during both conditions. During the hypnosis scan, the volunteers were under the hypnotists’ guidance to keep peace and stable respiration. To evaluate the altered physiological performance of hypnosis in the respiratory control, three conventional indicators ALFF/fALFF (0.01–0.08Hz) and ReHo, were applied to identify the difference. Results: Compared with RSC, HSC showed significant (p<0.05) higher ReHo in superior temporal gyrus, middle temporal gyrus, frontal lobe, middle occipital gyrus, parietal lobe, cerebellum anterior Lobe and lingual gyrus, and left brainstem (Fig.2). While significant lower ReHo in middle frontal gyrus, superior frontal gyrus, inferior semi-lunar lobule, sub-lobar and limbic lobe (Fig.2). As for the ALFF results, significant higher value of HSC was observed in superior temporal gyrus, middle temporal gyrus, middle occipital gyrus, middle occipital gyrus, cerebellum anterior lobe, lingual gyrus, sub-lobar, limbic lobe, and lower in cerebellum posterior lobe, inferior semi-lunar lobule, inferior parietal lobule right middle frontal gyrus, cerebellar tonsil (Fig.3). The results of fALFF were similar to ALFF (Fig.4). The above results demonstrated that most significant regions of brain were uniform between ReHo and ALFF/fALFF. Conclusion: Hypnosis is a new psychological and helpful technology for respiration control. This study provides new insights of neurological brain activity during hypnosis of respiration control. This work is supported by grants from Guangdong Innovative Research Team Program of China (Grant No. 2011S013), National 863 Programs of China (Grant Nos. 2012AA02A604 and 2015AA043203), the National High-tech R&D Program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917)

60 APPLIED LIFE SCIENCES↗

SU-F-J-151: Evaluation of a Magnetic Resonance Image Gated Radiotherapy System Using a Motion Phantom and Radiochromic Film

Purpose: Magnetic resonance image (MRI) guided radiotherapy enables gating directly on target position for soft-tissue targets in the lung and abdomen. We present a dosimetric evaluation of a commercially-available FDA-approved MRI-guided radiotherapy system’s gating performance using a MRI-compatible respiratory motion phantom and radiochromic film. Methods: The MRI-compatible phantom was capable of one-dimensional motion. The phantom consisted of a target rod containing high-contrast target inserts which moved inside a body structure containing background contrast material. The target rod was equipped with a radiochromic film insert. Treatment plans were generated for a 3 cm diameter spherical target, and delivered to the phantom at rest and in motion with and without gating. Both sinusoidal and actual tumor trajectories (two free-breathing trajectories and one repeated-breath hold) were used. Gamma comparison at 5%/3mm was used to measure fidelity to the static target dose distribution. Results: Without gating, gamma pass rates were 24–47% depending on motion trajectory. Using our clinical standard of repeated breath holds and a gating window of 3 mm with 10% of the target allowed outside the gating boundary, the gamma pass rate was 99.6%. Relaxing the gating window to 5 mm resulted in gamma pass rate of 98.6% with repeated breath holds. For all motion trajectories gated with 3 mm margin and 10% allowed out, gamma pass rates were between 64–100% (mean:87.5%). For a 5 mm margin and 10% allowed out, gamma pass rates were between 57–98% (mean: 82.49%), significantly lower than for 3 mm by paired t-test (p=0.01). Conclusion: We validated the performance of respiratory gating based on real-time cine MRI images with the only FDA-approved MRI-guided radiotherapy system. Our results suggest that repeated breath hold gating should be used when possible for best accuracy. A 3 mm gating margin is statistically significantly more accurate than a 5 mm gating margin.

60 APPLIED LIFE SCIENCES↗

Sci-Thur PM – Colourful Interactions: Highlights 07: Canadian Computed Tomography Survey: National Diagnostic Reference Levels

Purpose: The Canadian Computed (CT) Tomography Survey sought to collect CT technology and dose index data (CTDI and DLP) at the national level in order to establish national diagnostic reference levels (DRLs) for seven common CT examinations of standard-sized adults and pediatric patients. Methods: A single survey booklet (consisting of four sections) was mailed to and completed for each participating CT scanner. Survey sections collected data on (i) General facility and scanner information, (ii) routine protocols (as available), (iii) individual patient data (as applied) and (iv) manual CTDI measurements. Results: Dose index (CTDIvol and DLP) and associated patient data from 24 280 individual patient exam sequences was analyzed for seven common CT examinations performed in Canada: Adult Head, Chest, Abdomen/Pelvis, and Chest/Abdomen/Pelvis, and Pediatric Head, Chest, and Abdomen. Pediatric examination data was sub-divided into three age ranges: 0–3, 3–7 and 7–13 years. DRLs (75th percentile of dose index distributions) were found for all thirteen groups. Further analysis also permitted segmentation of examination data into 8 sub-groups, whose dose index data was displayed along with group histograms – showing relative contribution of axial vs. helical, contrast use (C+ vs. C-), and application of fixed current vs. dose reduction (DR) – 75th percentiles of DR sub-groups were, in almost all cases, lower than whole group (examination) DRLs. Conclusions: The analysis and summaries presented in the pending survey report can serve to aid local CT imaging optimization efforts within Canada and also contribute further to international efforts in radiation protection of patients.

60 APPLIED LIFE SCIENCES↗

Development and cross‐validation of a circumference‐based predictive equation to estimate body fat in an active population

Abstract Objective The U.S. Army uses sex‐specific circumference‐based prediction equations to estimate percent body fat (%BF) to evaluate adherence to body composition standards. The equations are periodically evaluated to ensure that they continue to accurately assess %BF in a diverse population. The objective of this study was to develop and validate alternative field expedient equations that may improve upon the current Army Regulation (AR) body fat (%BF) equations. Methods Body size and composition were evaluated in a representatively sampled cohort of 1904 active‐duty Soldiers (1261 Males, 643 Females), using dual‐energy X‐ray absorptiometry (%BF DXA ), and circumferences obtained with 3D imaging and manual measurements. Sex stratified linear prediction equations for %BF were constructed using internal cross validation with %BF DXA as the criterion measure. Prediction equations were evaluated for accuracy and precision using root mean squared error, bias, and intraclass correlations. Equations were externally validated in a convenient sample of 1073 Soldiers. Results Three new equations were developed using one to three circumference sites. The predictive values of waist, abdomen, hip circumference, weight and height were evaluated. Changing from a 3‐site model to a 1‐site model had minimal impact on measurements of model accuracy and performance. Male‐specific equations demonstrated larger gains in accuracy, whereas female‐specific equations resulted in minor improvements in accuracy compared to existing AR equations. Equations performed similarly in the second external validation cohort. Conclusions The equations developed improved upon the current AR equation while demonstrating robust and consistent results within an external population. The 1‐site waist circumference‐based equation utilized the abdominal measurement, which aligns with associated obesity related health outcomes. This could be used to identify individuals at risk for negative health outcomes for earlier intervention.

Taylor, Kathryn M.↗

A Method to Recognize Anatomical Site and Image Acquisition View in X-ray Images

A method was developed to recognize anatomical site and image acquisition view automatically in 2D X-ray images that are used in image-guided radiation therapy. The purpose is to enable site and view dependent automation and optimization in the image processing tasks including 2D-2D image registration, 2D image contrast enhancement, and independent treatment site confirmation. The X-ray images for 180 patients of six disease sites (the brain, head-neck, breast, lung, abdomen, and pelvis) were included in this study with 30 patients each site and two images of orthogonal views each patient. A hierarchical multiclass recognition model was developed to recognize general site first and then specific site. Each node of the hierarchical model recognized the images using a feature extraction step based on principal component analysis followed by a binary classification step based on support vector machine. Given two images in known orthogonal views, the site recognition model achieved a 99% average F1 score across the six sites. If the views were unknown in the images, the average F1 score was 97%. If only one image was taken either with or without view information, the average F1 score was 94%. The accuracy of the site-specific view recognition models was 100%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Positron emission tomography study on pancreatic somatostatin receptors in normal and diabetic rats with {sup 68}Ga-DOTA-octreotide: A potential PET tracer for beta cell mass measurement

Highlights: •PET images showed high uptake of {sup 68}Ga-DOTA-octreotide in the normal pancreas. •{sup 68}Ga-DOTA-octreotide specifically binds to somatostatin receptors in the pancreas. •The pancreatic uptake of {sup 68}Ga-DOTA-octreotide was decreased in the diabetic rats. •{sup 68}Ga-DOTA-octreotide could be a candidate PET probe to measure the beta cell mass. -- Abstract: Diabetes mellitus (DM) is a metabolic disorder characterized by hyperglycemia, and the loss or dysfunction of pancreatic beta cells has been reported before the appearance of clinical symptoms and hyperglycemia. To evaluate beta cell mass (BCM) for improving the detection and treatment of DM at earlier stages, we focused on somatostatin receptors that are highly expressed in the pancreatic beta cells, and developed a positron emission tomography (PET) probe derived from octreotide, a metabolically stable somatostatin analog. Octreotide was conjugated with 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA), a chelating agent, and labeled with {sup 68}Gallium ({sup 68}Ga). After intravenous injection of {sup 68}Ga-DOTA-octreotide, a 90-min emission scan of the abdomen was performed in normal and DM model rats. The PET studies showed that {sup 68}Ga-DOTA-octreotide radioactivity was highly accumulated in the pancreas of normal rats and that the pancreatic accumulation was significantly reduced in the rats administered with an excess amount of unlabeled octreotide or after treatment with streptozotocin, which was used for the chemical induction of DM in rats. These results were in good agreement with the ex vivo biodistribution data. These results indicated that the pancreatic accumulation of {sup 68}Ga-DOTA-octreotide represented specific binding to the somatostatin receptors and reflected BCM. Therefore, PET imaging with {sup 68}Ga-DOTA-octreotide could be a potential tool for evaluating BCM.

60 APPLIED LIFE SCIENCES↗

Adipocyte induced arterial calcification is prevented with sodium thiosulfate

Highlights: • High phosphorus can induce calcification of adipocytes, even when fully differentiated. • Adipocytes can induce vascular calcification in an autocrine manner. • Sodium thiosulfate inhibits adipocyte calcification. - Abstract: Background: Calcification can occur in fat in multiple clinical conditions including in the dermis, breasts and in the abdomen in calciphylaxis. All of these are more common in patients with advanced kidney disease. Clinically, hyperphosphatemia and obesity are risk factors. Thus we tested the hypothesis that adipocytes can calcify in the presence of elevated phosphorus and/or that adipocytes exposed to phosphorus can induce vascular smooth muscle cell (VSMC) calcification. Methods: 3T3-L1 preadipocytes were induced into mature adipocytes and then treated with media containing high phosphorus. Calcification was assessed biochemically and PCR performed to determine the expression of genes for osteoblast and adipocyte differentiation. Adipocytes were also co-cultured with bovine VSMC to determine paracrine effects, and the efficacy of sodium thiosulfate was determined. Results: The results demonstrated that high phosphorus induced the calcification of differentiated adipocytes with increased expression of osteopontin, the osteoblast transcription factor Runx2 and decreased expression of adipocyte transcription factors peroxisome proliferator-activated receptor γ (PPARγ) and CCAAT-enhancer-binding protein α (CEBPα), indicating that high phosphorus led to a phenotypic switch of adipocytes to an osteoblast like phenotype. Sodium thiosulfate, dose dependently decreased adipocyte calcification and inhibited adipocyte induced increase of VSMC calcification. Co-culture studies demonstrated that adipocytes facilitated VSMC calcification partially mediated by changes of secretion of leptin and vascular endothelial growth factor (VEGF) from adipocytes. Conclusion: High phosphorus induced calcification of mature adipocytes, and adipocytes exposed to elevated phosphorus can induce calcification of VSMC in a paracrine manner. Sodium thiosulfate inhibited this calcification and decreased the secretin of leptin and VEGF from adipocytes. These results suggest that adipocyte exposure to elevated phosphorus may be a pathogenic factor in calcification observed in the skin in calciphylaxis and other diseases.

60 APPLIED LIFE SCIENCES↗

Tracing the dynamic expression of the Nfκb2 gene during inflammatory processes by in vivo bioluminescence imaging in transgenic mice

Highlights: • Construct a mouse transgenic model line which could trace the p100/p50 expression by luciferase in vivo. • Nfκb2 could express in all mouse tissues and the luciferase expression could represent Nfκb2 expression in most tissues. • Lps induced inflammation could increase luciferase expression in certain stage. • In the IBD model, the fluorescence expression in mouse abdomen was coincide with the intestine after DSSfeed. Nfκb2(p52/p100) plays essential roles in many chronic inflammatory diseases. Tracing the dynamic expression of Nfκb2 during different biological processes in vivo can provide valuable clues to understand the biological functions of this gene and develop anti-inflammatory drugs. In this study, B6-Tg(Nfκb2-luc){sup Mlit} transgenic mouse line, a mouse model in which the expression of firefly luciferase gene is under the control of a 14.6-kb mouse Nfκb2 promoter, was generated to monitor the expression of p52/p100 in vivo. Bioluminescence imaging was used for tracking the luciferase signal in living mice in a variety of inflammatory processes, including LPS-induced sepsis and inflammatory bowel disease (IBD). The data of in vivo bioluminescence imaging in this mouse model showed that luciferase activity coincided with the endogenous p52/p100 expression. Moreover, dexamethasone or aspirin, two routine anti-inflammatory drugs, could decrease the high-level expression of luciferase induced by LPS. Overall, our results suggest that the B6-Tg(Nfκb2-luc){sup Mlit} mice represent a valuable reporter mouse model not only to monitor the expression of p52/p100 in physiological or pathological processes but also to evaluate the effects of various anti-inflammatory drug treatments in vivo.

60 APPLIED LIFE SCIENCES↗

Adaptations for gas exchange enabled the elongation of lepidopteran proboscises

The extensive biodiversification of butterflies and moths (Lepidoptera) is partly attributed to their unique mouthparts (proboscis [Pr]) that can span in length from less than 1 mm to over 280mm in Darwin's sphinx moths. Lepi-doptera, similar to other insects, are believed to inhale and exhale respiratory gases only through valve-like spi-racles on their thorax and abdomen, making gas exchange through the narrow tracheae (Tr) challenging for the elongated Pr. How Lepidoptera overcome distance effects for gas transport to the Pr is an open question that is important to understanding how the Pr elongated over evolutionary time. Here, we show with scanning electron microscopy and X-ray imaging that distance effects on gas exchange are overcome by previously unreported micropores on the Pr surface and by superhydrophobic Tr that prevent water loss and entry. We find that the density of micropores decreases monotonically along the Pr length with the maxima proportional to the Pr length and that micropore diameters produce a Knudsen number at the boundary between the slip and transition flow regimes. By numerical estimation, we further show that the respiratory gas exchange for the Pr predominantly occurs via diffusion through the micropores. In conclusion, these adaptations are key innovations vital to Pr elongation, which likely facilitated lepidopteran biodiversification and the radiation of angiosperms by coevolutionary processes.

59 BASIC BIOLOGICAL SCIENCES↗

Cloning and expressing a highly functional and substrate specific farnesoic acid o-methyltransferase from the Asian citrus psyllid ( Diaphorina citri Kuwayama)

The Asian citrus psyllid, Diaphorina citri , transmits a phloem-limited bacterium, Candidatus ‘Liberibacter’ asiaticus that causes citrus greening disease. Because juvenile hormone (JH) plays an important role in adult and nymphal development, we studied the final steps in JH biosynthesis in D. citri . A putative JH acid methyltransferase ortholog gene ( jmt D) and its cognate cDNA were identified by searching D. citri genome database. Expression analysis shows expression in all life stages. In adults, it is expressed in the head-thorax, (containing the corpora allata), and the abdomen (containing ovaries and male accessory glands). A 3D protein model identified the catalytic groove with catalytically active amino acids and the S-adenosyl methionine (SAM)-binding loop. The cDNA was expressed in Escherichia coli cells and the purified enzyme showed high preference for farnesoic acid (FA) and homoFA ( k cat of 0.752 × 10 –3 and 0.217 × 10 –3 s –1 , respectively) as compared to JH acid I (JHA I) ( cis/trans/cis ; 2 Z , 6 E , 10 cis ), JHA III (2 E , 6 E , 10cis ), and JHA I ( trans / cis / cis ; 2 E , 2 Z , 10 cis ) ( k cat of 0.081 × 10 –3 , 0.013 × 10 –3 , and 0.003 × 10 –3 s –1 , respectively). This suggests that this ortholog is a Dc FA-o-methyl transferase gene ( fmt D), not a jmt D, and that JH biosynthesis in D. citri proceeds from FA to JH III through methyl farnesoate (MF). Dc FA-o-MT does not require Ca 2+ , Mg 2+ or Zn 2+ , however, Zn 2+ (1 mM) completely inhibits the enzyme probably by binding H115 at the active groove. This represents the first purified FA-o-MT from Hemiptera with preferred biological activity for FA and not JHA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neoadjuvant Chemoradiation With Paclitaxel/Carboplatin for Selected Stage III Non-Small-Cell Lung Cancer: Long-Term Results of a Trimodality Phase II Protocol

Purpose: To evaluate, in a Phase II trial conducted August 1998 through January 2001, the efficacy of neoadjuvant chemotherapy followed by chemoradiotherapy and definitive surgery in patients with locally advanced non-small-cell lung cancer (LA-NSCLC), Stages IIIA bulky and selected Stage IIIB. Patients and Methods: Staging of LA-NSCLC included computed tomography of cranium, thorax, and abdomen, whole-body positron emission tomography, and video mediastinoscopy. Induction chemotherapy with weekly paclitaxel and carboplatin was followed by hyperfractionated accelerated thoracic radiotherapy (45 Gy) with simultaneous weekly paclitaxel and carboplatin. Four to six weeks after completion of induction therapy, restaging and resection of primary tumor and lymph nodes was intended. Results: A total of 59 consecutive patients were enrolled, 25% with Stage IIIA bulky disease, 65% with Stage IIIB, and 10% with Stage IV (excluded from further analysis). Forty-one patients completed induction therapy; in 52.4% a functional (positron emission tomography) downstaging was proven. Thirty-two patients (59.3%) underwent complete tumor resection, and 5 patients had an exploratory thoracotomy only. Histopathologic downstaging was proven in 59.4% and complete response in 21.9%. Hospital mortality was 5.4%. Median duration of follow-up for living patients was 62.1 months. Overall median survival was 22.6 months, 58.2 months for completely resected patients. During induction chemotherapy, Grade 3/4 granulocytopenia occurred in 8% of patients; the most common Grade 3/4 toxicity of chemoradiation was esophagitis, in 26.4% of patients. Conclusions: Induction paclitaxel/carboplatin with hyperfractionated accelerated chemoradiotherapy followed by complete tumor resection demonstrates high efficacy in LA-NSCLC and offers a promising chance of long-term survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Portal Hypertension in Children With Wilms' Tumor: A Report From the National Wilms' Tumor Study Group

Purpose: This analysis was undertaken to determine the cumulative risk of and risk factors for portal hypertension (PHTN) in patients with Wilms' tumor (WT). Methods and Materials: Medical records were reviewed to identify cases of PHTN identified with late liver/spleen/gastric toxicities in a cohort of 5,195 patients treated with National Wilms' Tumor Studies (NWTS) protocols 1 to 4. A nested case control study (5 controls/case) was conducted to determine relationships among doxorubicin, radiation therapy (RT) dose to the liver, patient gender, and PHTN. Conditional logistic regression was used to estimate adjusted hazard ratios (HR) of PHTN associated with these factors. Results: Cumulative risk of PHTN at 6 years from WT diagnosis was 0.7% for patients with right-sided tumors vs. 0.1% for those with left-sided tumors (p = 0.002). Seventeen of 19 cases were evaluable for RT. The majority of cases (16/17 [94%]) received right-flank RT either alone or as part of whole-abdomen RT and received >15 Gy to the liver. Fifteen of 17 (88%) patients received a higher dose to the liver than they would have with modern WT protocols. Controlling for RT dose, the HR was 3.0 for patients who received doxorubicin (p = 0.32) and 2.8 for females (p = 0.15). Controlling for doxorubicin, the 95% lower confidence bound on the HR associating PHTN with a minimum liver RT dose of >15 Gy vs. <=15 Gy was 2.5 (p = 0.001); it was 2.4 for a maximum liver dose of >15 Gy vs. <=15 Gy (p = 0.001). Conclusions: There was a strong association between higher doses of liver RT (>15 Gy) and the development of PHTN among WT patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Value of Combined PET/CT for Radiation Planning in CT-Guided Percutaneous Interstitial High-Dose-Rate Single-Fraction Brachytherapy for Colorectal Liver Metastases

Purpose: To determine the additional value of fluorodeoxyglucose-positron emission tomography (PET) for clinical target volume definition in the planning of computed tomography (CT)-guided interstitial brachytherapy for liver metastases. Patients and Methods: A total of 19 patients with liver metastases from colorectal cancer treated in 25 sessions were included in the present study. All patients had undergone fluorodeoxyglucose-PET for patient evaluation before interstitial CT-guided brachytherapy. A contrast-enhanced CT scan of the upper abdomen was obtained for radiation planning. The clinical target volume (CTV) was defined by a radiation oncologist and radiologist. After registration of the CT scan with the PET data set, the target volume was defined again using the fusion images. Results: PET revealed one additional liver lesion that was not visible on CT. The median CT-CTV (defined using CT and magnetic resonance imaging) was 68 cm{sup 3} (range 4-260). The PET/CT-CTV (median, 78 cm{sup 3}; range, 4-273) was significantly larger, with a median gain of 24.5% (interquartile range, 2.1-71.5%; p = .022). An increased CTV was observed in 15 cases and a decrease in 6; in 4 cases, the CT-CTV and PET/CT-CTV were equal. Incomplete dose coverage of PET/CT-CTVs was indicative of early local progression (p = .004); however, CT-based radiation plans did not show significant differences in the local control rates when stratified by dose coverage. Conclusion: Retrospective implementation of fluorodeoxyglucose-PET for CTV specification for CT-guided brachytherapy for colorectal liver metastases revealed a significant change in the CTVs. Additional PET-positive tumor regions with incomplete dose coverage could explain unexpected early local progression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bioluminescence Tomography–Guided Radiation Therapy for Preclinical Research

Purpose: In preclinical radiation research, it is challenging to localize soft tissue targets based on cone beam computed tomography (CBCT) guidance. As a more effective method to localize soft tissue targets, we developed an online bioluminescence tomography (BLT) system for small-animal radiation research platform (SARRP). We demonstrated BLT-guided radiation therapy and validated targeting accuracy based on a newly developed reconstruction algorithm. Methods and Materials: The BLT system was designed to dock with the SARRP for image acquisition and to be detached before radiation delivery. A 3-mirror system was devised to reflect the bioluminescence emitted from the subject to a stationary charge-coupled device (CCD) camera. Multispectral BLT and the incomplete variables truncated conjugate gradient method with a permissible region shrinking strategy were used as the optimization scheme to reconstruct bioluminescent source distributions. To validate BLT targeting accuracy, a small cylindrical light source with high CBCT contrast was placed in a phantom and also in the abdomen of a mouse carcass. The center of mass (CoM) of the source was recovered from BLT and used to guide radiation delivery. The accuracy of the BLT-guided targeting was validated with films and compared with the CBCT-guided delivery. In vivo experiments were conducted to demonstrate BLT localization capability for various source geometries. Results: Online BLT was able to recover the CoM of the embedded light source with an average accuracy of 1 mm compared to that with CBCT localization. Differences between BLT- and CBCT-guided irradiation shown on the films were consistent with the source localization revealed in the BLT and CBCT images. In vivo results demonstrated that our BLT system could potentially be applied for multiple targets and tumors. Conclusions: The online BLT/CBCT/SARRP system provides an effective solution for soft tissue targeting, particularly for small, nonpalpable, or orthotopic tumor models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗